Abstract
Background: Every day human skin is exposed to infrared A (IRA) radiation as part of the natural sun rays. As IRA radiation accounts for around one third of the solar radiation, it has gained great attention concerning its effects on the human body and skin. In the past few years it has been discussed controversially whether IRA radiation (of solar origin) is harmful or not. Nonetheless, there are several sunscreens on the German market that claim IRA protection for themselves. Aims: The present study seeks to find an experimental set-up and a test procedure for the determination and quantification of direct IRA protection (realized via reflection or absorption of the IRA radiation), since to our knowledge these do not yet exist. Methods: In this study we proved the usability of a set-up consisting of a light source, an IRA-transmissible filter system and a sensor unit, for the determination and quantification of the IRA protection of cosmetic and non-cosmetic samples. Results/Conclusion: The applicability of the IRA emission of the light source, the spectral detector, transmissivity of the filter systems and the sample carriers could be validated. This experimental set-up can be used as an in vitro test procedure for the determination of direct IRA protection.