Background: In this study, we describe a technique of optimizing the accuracy of frameless deep brain stimulation (DBS) lead placement through the use of a cannula poised at the entry to predict the location of the fully inserted device. This allows real-time correction of error prior to violation of the deep gray matter. Methods: We prospectively gathered data on radial error during the operative placements of 40 leads in 28 patients using frameless fiducial-less DBS surgery. Once the Nexframe had been aligned to target, a cannula was inserted through the center channel of the BenGun until it traversed the pial surface and a low-dose O-arm spin was obtained. Using 2 points along the length of the imaged cannula, a trajectory line was projected to target depth. If lead location could be improved, the cannula was inserted through an alternate track in the BenGun down to target depth. After intraoperative microelectrode recording and clinical assessment, another O-arm spin was obtained to compare the location of the inserted lead with the location predicted by the poised cannula. Results: The poised cannula projection and the actual implant had a mean radial discrepancy of 0.75 ± 0.64 mm. The poised cannula projection identified potentially clinically significant errors (avg 2.07 ± 0.73 mm) in 33% of cases, which were reduced to a radial error of 1.33 ± 0.66 mm (p = 0.02) after correction using an alternative BenGun track. The final target to implant error for all 40 leads was 1.20 ± 0.52 mm with only 2.5% of errors being >2.5 mm. Conclusion: The poised cannula technique results in a reduction of large errors (>2.5 mm), resulting in a decline in these errors to 2.5% of implants as compared to 17% in our previous publication using the fiducial-less method and 4% using fiducial-based methods of DBS lead placement.

This content is only available via PDF.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.