Stereoelectroencephalography (SEEG) in children with intractable epilepsy presents particular challenges. Their thin and partially ossified cranium, specifically in the temporal area, is prone to fracture while attaching stereotactic systems to the head or stabilizing the head in robot’s field of action. Postponing SEEG in this special population of patients can have serious consequences, reducing their chances of becoming seizure-free and impacting their social and cognitive development. This study demonstrates the safety and accuracy offered by a frameless personalized 3D printed stereotactic implantation system for SEEG investigations in children under 4 years of age. SEEG was carried out in a 3-year-old patient with drug-resistant focal epilepsy, based on a right temporal-perisylvian epileptogenic zone hypothesis. Fifteen intracerebral electrodes were placed using a StarFix patient-customized stereotactic fixture. The median lateral entry point localization error of the electrodes was 0.90 mm, median lateral target point localization error was 1.86 mm, median target depth error was 0.83 mm, and median target point localization error was 1.96 mm. There were no perioperative complications. SEEG data led to a tailored right temporal-insular-opercular resection, with resulting seizure freedom (Engel IA). In conclusion, patient-customized stereotactic fixtures are a safe and accurate option for SEEG exploration in young children.

1.
Brodie
MJ
.
Road to refractory epilepsy: the Glasgow story
.
Epilepsia
.
2013 May
;
54
(
Suppl 2
):
5
8
. .
2.
Chen
Z
,
Brodie
MJ
,
Liew
D
,
Kwan
P
.
Treatment outcomes in patients with newly diagnosed epilepsy treated with established and new antiepileptic drugs: a 30-year longitudinal cohort study
.
JAMA Neurol
.
2018 Mar
;
75
(
3
):
279
86
. .
3.
Wiebe
S
,
Blume
WT
,
Girvin
JP
,
Eliasziw
M
.
A randomized, controlled trial of surgery for temporal-lobe epilepsy
.
N Engl J Med
.
2001 Aug
;
345
(
5
):
311
8
. .
4.
Engel
J
,
McDermott
MP
,
Wiebe
S
,
Langfitt
JT
,
Stern
JM
,
Dewar
S
, et al.
Early surgical therapy for drug-resistant temporal lobe epilepsy: a randomized trial
.
JAMA
.
2012 Mar
;
307
(
9
):
922
30
. .
5.
Dwivedi
R
,
Ramanujam
B
,
Chandra
PS
,
Sapra
S
,
Gulati
S
,
Kalaivani
M
, et al.
Surgery for drug-resistant epilepsy in children
.
N Engl J Med
.
2017 Oct
;
377
(
17
):
1639
47
. .
6.
Mullin
JP
,
Shriver
M
,
Alomar
S
,
Najm
I
,
Bulacio
J
,
Chauvel
P
, et al.
Is SEEG safe? A systematic review and meta-analysis of stereo-electroencephalography-related complications
.
Epilepsia
.
2016 Mar
;
57
(
3
):
386
401
. .
7.
Noe
KH
,
Drazkowski
JF
.
Safety of long-term video-electroencephalographic monitoring for evaluation of epilepsy
.
Mayo Clin Proc
.
2009 Jun
;
84
(
6
):
495
500
. .
8.
Cardinale
F
,
Cossu
M
,
Castana
L
,
Casaceli
G
,
Schiariti
MP
,
Miserocchi
A
, et al.
Stereoelectroencephalography: surgical methodology, safety, and stereotactic application accuracy in 500 procedures
.
Neurosurgery
.
2013
;
72
(
3
):
353
66
. .
9.
Yu
H
,
Pistol
C
,
Franklin
R
,
Barborica
A
.
Clinical accuracy of customized stereotactic fixtures for stereoelectroencephalography
.
World Neurosurg
.
2018
;
109
:
82
8
. .
10.
Candela-Canto
S
,
Aparicio
J
,
Lopez
JM
,
Banos-Carrasco
P
,
Ramirez-Camacho
A
,
Climent
A
, et al.
Frameless robot-assisted stereoelectroencephalography for refractory epilepsy in pediatric patients: accuracy, usefulness, and technical issues
.
Acta Neurochir
.
2018 Dec
;
160
(
12
):
2489
500
. .
11.
Youngerman
BE
,
Khan
FA
,
McKhann
GM
.
Stereoelectroencephalography in epilepsy, cognitive neurophysiology, and psychiatric disease: safety, efficacy, and place in therapy
.
Neuropsychiatr Dis Treat
.
2019
;
15
:
1701
16
. .
12.
Tomlinson
SB
,
Buch
VP
,
Armstrong
D
,
Kennedy
BC
.
Stereoelectroencephalography in pediatric epilepsy surgery
.
J Korean Neurosurg Soc
.
2019 May
;
62
(
3
):
302
12
. .
13.
Li
Z
,
Zhang
JG
,
Ye
Y
,
Li
X
.
Review on factors affecting targeting accuracy of deep brain stimulation electrode implantation between 2001 and 2015
.
Stereotact Funct Neurosurg
.
2016
;
94
(
6
):
351
62
. .
14.
Verburg
N
,
Baayen
JC
,
Idema
S
,
Klitsie
MA
,
Claus
S
,
de Jonge
CS
, et al.
In vivo accuracy of a frameless stereotactic drilling technique for diagnostic biopsies and stereoelectroencephalography depth electrodes
.
World Neurosurg
.
2016 Mar
;
87
:
392
8
. .
15.
Ho
AL
,
Feng
AY
,
Kim
LH
,
Pendharkar
AV
,
Sussman
ES
,
Halpern
CH
, et al.
Stereoelectroencephalography in children: a review
.
Neurosurg Focus
.
2018 Sep
;
45
(
3
):
E7
. .
16.
Harary
M
,
Cosgrove
GR
.
Jean Talairach: a cerebral cartographer
.
Neurosurg Focus
.
2019 Sep
;
47
(
3
):
E12
. .
17.
van der Loo
LE
,
Schijns
OEMG
,
Hoogland
G
,
Colon
AJ
,
Wagner
GL
,
Dings
JTA
, et al.
Methodology, outcome, safety and in vivo accuracy in traditional frame-based stereoelectroencephalography
.
Acta Neurochir
.
2017 Sep
;
159
(
9
):
1733
46
. .
18.
Vakharia
VN
,
Sparks
R
,
O’Keeffe
AG
,
Rodionov
R
,
Miserocchi
A
,
McEvoy
A
, et al.
Accuracy of intracranial electrode placement for stereoencephalography: a systematic review and meta-analysis
.
Epilepsia
.
2017
;
58
(
6
):
921
32
. .
19.
Taussig
D
,
Dorfmüller
G
,
Fohlen
M
,
Jalin
C
,
Bulteau
C
,
Ferrand-Sorbets
S
, et al.
Invasive explorations in children younger than 3 years
.
Seizure
.
2012 Oct
;
21
(
8
):
631
8
. .
20.
Miller
BA
,
Salehi
A
,
Limbrick
DD
,
Smyth
MD
.
Applications of a robotic stereotactic arm for pediatric epilepsy and neurooncology surgery
.
J Neurosurg Pediatr
.
2017 Oct
;
20
(
4
):
364
70
. .
21.
Abel
TJ
,
Varela Osorio
R
,
Amorim-Leite
R
,
Mathieu
F
,
Kahane
P
,
Minotti
L
, et al.
Frameless robot-assisted stereoelectroencephalography in children: technical aspects and comparison with Talairach frame technique
.
J Neurosurg Pediatr
.
2018 Jul
;
22
(
1
):
37
46
. .
22.
Dewan
MC
,
Shults
R
,
Hale
AT
,
Sukul
V
,
Englot
DJ
,
Konrad
P
, et al.
Stereotactic EEG via multiple single-path omnidirectional trajectories within a single platform: institutional experience with a novel technique
.
J Neurosurg
.
2018 Dec
;
129
(
5
):
1173
81
. .
23.
D'Agostino
E
,
Kanter
J
,
Song
Y
,
Aronson
JP
.
Stereoencephalography Electrode Placement Accuracy and Utility Using a Frameless Insertion Platform Without a Rigid Cannula
.
Oper Neurosurg (Hagerstown)
.
2020 Apr
;
18
(
4
):
409
16
.
24.
Barborica
A
,
Ciurea
J
,
Ioana
M
,
Balanescu
B
,
Donos
C
.
A vascular safety index for sterotactic targeting of deep brain structures
.
Stereotact Funct Neurosurg
.
2012
;
1
(
90
1
):
121
. .
25.
Arnulfo
G
,
Narizzano
M
,
Cardinale
F
,
Fato
MM
,
Palva
JM
.
Automatic segmentation of deep intracerebral electrodes in computed tomography scans
.
BMC Bioinformatics
.
2015
;
16
:
99
. .
26.
Fedorov
A
,
Beichel
R
,
Kalpathy-Cramer
J
,
Finet
J
,
Fillion-Robin
JC
,
Pujol
S
, et al.
3D Slicer as an image computing platform for the Quantitative Imaging Network
.
Magn Reson Imaging
.
2012 Nov
;
30
(
9
):
1323
41
. .
27.
Balanescu
B
,
Franklin
R
,
Ciurea
J
,
Mindruta
I
,
Rasina
A
,
Bobulescu
RC
, et al.
A personalized stereotactic fixture for implantation of depth electrodes in stereoelectroencephalography
.
Stereotact Funct Neurosurg
.
2014
;
92
(
2
):
117
25
. .
28.
Munari
C
,
Bancaud
J
.
The role of stereo-electro-encephalography (SEEG) in the evaluation of partial epileptic patients
. In:
Porter
RJ
,
Morselli
PL
, editors.
The epilepsies
.
London
:
Butterworths
;
1987
. p.
267
306
.
29.
Spencer
DD
,
Ojemann
GA
.
Outcome with respect to epileptic seizures
. In:
Engel
JJ
, editor.
Surgical treatment of the epilepsies
.
New York
:
Raven Press
;
1993
. p.
609
21
.
30.
Cardinale
F
,
Rizzi
M
,
d’Orio
P
,
Casaceli
G
,
Arnulfo
G
,
Narizzano
M
, et al.
A new tool for touch-free patient registration for robot-assisted intracranial surgery: application accuracy from a phantom study and a retrospective surgical series
.
Neurosurg Focus
.
2017 May
;
42
(
5
):
E8
. .
31.
Sharma
JD
,
Seunarine
KK
,
Tahir
MZ
,
Tisdall
MM
.
Accuracy of robot-assisted versus optical frameless navigated stereoelectroencephalography electrode placement in children
.
J Neurosurg Pediatr
.
2019 Jan
;
23
(
3
):
297
302
. .
32.
Yan
H
,
Katz
JS
,
Anderson
M
,
Mansouri
A
,
Remick
M
,
Ibrahim
GM
, et al.
Method of invasive monitoring in epilepsy surgery and seizure freedom and morbidity: a systematic review
.
Epilepsia
.
2019 Sep
;
60
(
9
):
1960
72
. .
33.
Furlanetti
LL
,
Monaco
BA
,
Cordeiro
JG
,
Lopez
WOC
,
Trippel
M
.
Frame-based stereotactic neurosurgery in children under the age of seven: Freiburg University’s experience from 99 consecutive cases
.
Clin Neurol Neurosurg
.
2015 Mar
;
130
:
42
7
. .
34.
Taussig
D
,
Chipaux
M
,
Lebas
A
,
Fohlen
M
,
Bulteau
C
,
Ternier
J
, et al.
Stereo-electroencephalography (SEEG) in 65 children: an effective and safe diagnostic method for pre-surgical diagnosis, independent of age
.
Epileptic Disord
.
2014 Sep
;
16
(
3
):
280
95
. .
35.
Cardinale
F
,
Casaceli
G
,
Raneri
F
,
Miller
J
,
Lo Russo
G
.
Implantation of stereoelectroencephalography electrodes: a systematic review
.
J Clin Neurophysiol
.
2016 Dec
;
33
(
6
):
490
502
. .
36.
Shurtleff
HA
,
Barry
D
,
Firman
T
,
Warner
MH
,
Aguilar-Estrada
RL
,
Saneto
RP
, et al.
Impact of epilepsy surgery on development of preschool children: identification of a cohort likely to benefit from early intervention
.
J Neurosurg Pediatr
.
2015 Oct
;
16
(
4
):
383
92
. .
37.
Pelliccia
V
,
Deleo
F
,
Gozzo
F
,
Sartori
I
,
Mai
R
,
Cossu
M
, et al.
Early and late epilepsy surgery in focal epilepsies associated with long-term epilepsy-associated tumors
.
J Neurosurg
.
2017 Nov
;
127
(
5
):
1147
52
. .
38.
Vakharia
VN
,
Duncan
JS
,
Witt
JA
,
Elger
CE
,
Staba
R
,
Engel
J
.
Getting the best outcomes from epilepsy surgery
.
Ann Neurol
.
2018 Apr
;
83
(
4
):
676
90
. .
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.