Background: Accurate implantation of a depth electrode into the brain is of the greatest importance in deep brain stimulation (DBS), and various stereotactic systems have been developed for electrode implantation. However, an updated analysis of depth electrode implantation in the modern era of DBS is lacking. Objective: This study aims at providing an updated review on targeting accuracy of DBS electrode implantation by analyzing contemporary DBS electrode implantation operations from the perspective of precision engineering. Methods: Eligible articles with information on targeting accuracy of DBS electrode implantation were searched in the PubMed database. Results: An average targeting error of DBS electrode implantation is reported to decrease toward 1 mm; the standard deviation of targeting error is decreasing toward 0.5 mm. Targeting accuracy is not only found to be affected by individual surgical steps, but also systematically affected by the architecture of the implantation operation. Conclusion: A systematic strategy should be adopted to further improve the targeting accuracy of depth electrode implantation. Attention should be paid to optimizing the whole electrode implantation operation, which can help minimize error accumulation or amplification throughout the serially connected procedures for DBS electrode implantation.

1.
Delgado JM, Hamlin H, Chapman WP: Technique of intracranial electrode implacement for recording and stimulation and its possible therapeutic value in psychotic patients. Confin Neurol 1952;12:315-319.
[PubMed]
2.
Benabid AL, Pollak P, Louveau A, Henry S, Derougemont J: Combined (thalamotomy and stimulation) stereotactic surgery of the VIM thalamic nucleus for bilateral Parkinson disease. Appl Neurophysiol 1987;50:344-346.
[PubMed]
3.
Hariz MI, Blomstedt P, Zrinzo L: Deep brain stimulation between 1947 and 1987: the untold story. Neurosurg Focus 2010;29:E1.
[PubMed]
4.
Benabid AL, Pollak P, Gervason C, Hoffmann D, Gao DM, Hommel M, Perret JE, de Rougemont J: Long-term suppression of tremor by chronic stimulation of the ventral intermediate thalamic nucleus. Lancet 1991;337:403-406.
[PubMed]
5.
Gielen FLH: Deep brain stimulation: current practice and challenges for the future. 1st IEEE EMBS Conf Neural Eng, Capri, 2003, pp 489-491.
6.
Abelson JL, Curtis GC, Sagher O, Albucher RC, Harrigan M, Taylor SF, Martis B, Giordani B: Deep brain stimulation for refractory obsessive-compulsive disorder. Biol Psychiatry 2005;57:510-516.
[PubMed]
7.
Mayberg HS, Lozano AM, Voon V, McNeely HE, Seminowicz D, Hamani C, Schwalb JM, Kennedy SH: Deep brain stimulation for treatment-resistant depression. Neuron 2005;45:651-660.
[PubMed]
8.
Feil J, Zangen A: Brain stimulation in the study and treatment of addiction. Neurosci Biobehav Rev 2010;34:559-574.
[PubMed]
9.
Anderson RJ, Frye MA, Abulseoud OA, Lee KH, McGillivray JA, Berk M, Tye SJ: Deep brain stimulation for treatment-resistant depression: efficacy, safety and mechanisms of action. Neurosci Biobehav Rev 2012;36:1920-1933.
[PubMed]
10.
Laxton AW, Tang-Wai DF, McAndrews MP, Zumsteg D, Wennberg R, Keren R, Wherrett J, Naglie G, Hamani C, Smith GS, Lozano AM: A phase I trial of deep brain stimulation of memory circuits in Alzheimer's disease. Ann Neurol 2010;68:521-534.
[PubMed]
11.
Sankar T, Chakravarty MM, Bescos A, Lara M, Obuchi T, Laxton AW, McAndrews MP, Tang-Wai DF, Workman CI, Smith GS, Lozano AM: Deep brain stimulation influences brain structure in Alzheimer's disease. Brain Stimul 2015;8:645-654.
[PubMed]
12.
Martin AJ, Larson PS, Ostrem JL, Keith Sootsman W, Talke P, Weber OM, Levesque N, Myers J, Starr PA: Placement of deep brain stimulator electrodes using real-time high-field interventional magnetic resonance imaging. Magn Reson Med 2005;54:1107-1114.
[PubMed]
13.
Patel NK, Plaha P, Gill SS: Magnetic resonance imaging-directed method for functional neurosurgery using implantable guide tubes. Neurosurgery 2007;61:358-365.
[PubMed]
14.
Shin M, Penholate MF, Lefaucheur JP, Gurruchaga JM, Brugieres P, Nguyen JP: Assessing accuracy of the magnetic resonance imaging-computed tomography fusion images to evaluate the electrode positions in subthalamic nucleus after deep-brain stimulation. Neurosurgery 2010;66:1193-1202.
[PubMed]
15.
Starr PA, Martin AJ, Ostrem JL, Talke P, Levesque N, Larson PS: Subthalamic nucleus deep brain stimulator placement using high-field interventional magnetic resonance imaging and a skull-mounted aiming device: technique and application accuracy. J Neurosurg 2010;112:479-490.
[PubMed]
16.
Shahlaie K, Larson PS, Starr PA: Intraoperative computed tomography for deep brain stimulation surgery: technique and accuracy assessment. Neurosurgery 2011;68:114-124.
[PubMed]
17.
Duffner F, Schiffbauer H, Breit S, Friese S, Freudenstein D: Relevance of image fusion for target point determination in functional neurosurgery. Acta Neurochir (Wien) 2002;144:445-451.
[PubMed]
18.
Cuny E, Guehl D, Burbaud P, Gross C, Dousset V, Rougier A: Lack of agreement between direct magnetic resonance imaging and statistical determination of a subthalamic target: the role of electrophysiological guidance. J Neurosurg 2002;97:591-597.
[PubMed]
19.
Schrader B, Hamel W, Weinert D, Mehdorn HM: Documentation of electrode localization. Mov Disord 2002;17:S167-S174.
[PubMed]
20.
Fiegele T, Feuchtner G, Sohm F, Bauer R, Anton JV, Gotwald T, Twerdy K, Eisner W: Accuracy of stereotactic electrode placement in deep brain stimulation by intraoperative computed tomography. Parkinsonism Relat Disord 2008;14:595-599.
[PubMed]
21.
Holloway KL, Gaede SE, Starr PA, Rosenow JM, Ramakrishnan V, Henderson JM: Frameless stereotaxy using bone fiducial markers for deep brain stimulation. J Neurosurg 2005;103:404-413.
[PubMed]
22.
Fitzpatrick JM, Konrad PE, Nickele C, Cetinkaya E, Kao C: Accuracy of customized miniature stereotactic platforms. Stereotact Funct Neurosurg 2005;83:25-31.
[PubMed]
23.
Smith AP, Bakay RA: Frameless deep brain stimulation using intraoperative O-arm technology. Clinical article. J Neurosurg 2011;115:301-309.
[PubMed]
24.
Maciunas RJ, Galloway RL Jr, Latimer JW: The application accuracy of stereotactic frames. Neurosurgery 1994;35:682-694.
[PubMed]
25.
Patel NK, Heywood P, O'Sullivan K, Love S, Gill SS: MRI-directed subthalamic nucleus surgery for Parkinson's disease. Stereotact Funct Neurosurg 2002;78:132-145.
[PubMed]
26.
Bjartmarz H, Rehncrona S: Comparison of accuracy and precision between frame-based and frameless stereotactic navigation for deep brain stimulation electrode implantation. Stereotact Funct Neurosurg 2007;85:235-242.
[PubMed]
27.
D'Haese PF, Pallavaram S, Konrad PE, Neimat J, Fitzpatrick JM, Dawant BM: Clinical accuracy of a customized stereotactic platform for deep brain stimulation after accounting for brain shift. Stereotact Funct Neurosurg 2010;88:81-87.
[PubMed]
28.
Abosch A, Timmermann L, Bartley S, Rietkerk HG, Whiting D, Connolly PJ, Lanctin D, Hariz MI: An international survey of deep brain stimulation procedural steps. Stereotact Funct Neurosurg 2013;91:1-11.
[PubMed]
29.
Kelman C, Ramakrishnan V, Davies A, Holloway K: Analysis of stereotactic accuracy of the Cosman-Robert-Wells frame and Nexframe frameless systems in deep brain stimulation surgery. Stereotact Funct Neurosurg 2010;88:288-295.
[PubMed]
30.
Holloway K, Docef A: A quantitative assessment of the accuracy and reliability of O-arm images for deep brain stimulation surgery. Neurosurgery 2013;72:47-57.
[PubMed]
31.
Lumsden DE, Ashmore J, Charles-Edwards G, Lin JP, Ashkan K, Selway R: Accuracy of stimulating electrode placement in paediatric pallidal deep brain stimulation for primary and secondary dystonia. Acta Neurochir (Wien) 2013;155:823-836.
[PubMed]
32.
Burchiel KJ, McCartney S, Lee A, Raslan AM: Accuracy of deep brain stimulation electrode placement using intraoperative computed tomography without microelectrode recording. J Neurosurg 2013;119:301-306.
[PubMed]
33.
Holl EM, Petersen EA, Foltynie T, Martinez-Torres I, Limousin P, Hariz MI, Zrinzo L: Improving targeting in image-guided frame-based deep brain stimulation. Neurosurgery 2010;67:437-447.
[PubMed]
34.
Zrinzo L, van Hulzen AL, Gorgulho AA, Limousin P, Staal MJ, De Salles AA, Hariz MI: Avoiding the ventricle: a simple step to improve accuracy of anatomical targeting during deep brain stimulation. J Neurosurg 2009;110:1283-1290.
[PubMed]
35.
Starr PA, Markun LC, Larson PS, Volz MM, Martin AJ, Ostrem JL: Interventional MRI-guided deep brain stimulation in pediatric dystonia: first experience with the ClearPoint system. J Neurosurg Pediatr 2014;14:400-408.
[PubMed]
36.
Zrinzo L: Pitfalls in precision stereotactic surgery. Surg Neurol Int 2012;3:S53-S61.
[PubMed]
37.
Ferroli P, Franzini A, Marras C, Maccagnano E, D'Incerti L, Broggi G: A simple method to assess accuracy of deep brain stimulation electrode placement: pre-operative stereotactic CT+ postoperative MR image fusion. Stereotact Funct Neurosurg 2004;82:14-19.
[PubMed]
38.
Hamid NA, Mitchell RD, Mocroft P, Westby GW, Milner J, Pall H: Targeting the subthalamic nucleus for deep brain stimulation: technical approach and fusion of pre- and postoperative MR images to define accuracy of lead placement. J Neurol Neurosurg Psychiatry 2005;76:409-414.
[PubMed]
39.
Pollo C, Vingerhoets F, Pralong E, Ghika J, Maeder P, Meuli R, Thiran JP, Villemure JG: Localization of electrodes in the subthalamic nucleus on magnetic resonance imaging. J Neurosurg 2007;106:36-44.
[PubMed]
40.
Fukaya C, Sumi K, Otaka T, Obuchi T, Kano T, Kobayashi K, Oshima H, Yamamoto T, Katayama Y: Nexframe frameless stereotaxy with multitract microrecording: accuracy evaluated by frame-based stereotactic X-ray. Stereotact Funct Neurosurg 2010;88:163-168.
[PubMed]
41.
Thani NB, Bala A, Lind CR: Accuracy of magnetic resonance imaging-directed frame-based stereotaxis. Neurosurgery 2012;70:114-123.
[PubMed]
42.
Daniluk S, Davies KG, Novak P, Vu T, Nazzaro JM, Ellias SA: Isolation of the brain-related factor of the error between intended and achieved position of deep brain stimulation electrodes implanted into the subthalamic nucleus for the treatment of Parkinson's disease. Neurosurgery 2009;64:374-382.
[PubMed]
43.
Von Langsdorff D, Paquis P, Fontaine D: In vivo measurement of the frame-based application accuracy of the Neuromate neurosurgical robot. J Neurosurg 2015;122:191-194.
[PubMed]
44.
Konrad PE, Neimat JS, Yu H, Kao CC, Remple MS, D'Haese PF, Dawant BM: Customized, miniature rapid-prototype stereotactic frames for use in deep brain stimulator surgery: initial clinical methodology and experience from 263 patients from 2002 to 2008. Stereotact Funct Neurosurg 2011;89:34-41.
[PubMed]
45.
Starr PA, Christine CW, Theodosopoulos PV, Lindsey N, Byrd D, Mosley A, Marks WJ: Implantation of deep brain stimulators into the subthalamic nucleus: technical approach and magnetic resonance imaging-verified lead locations. J Neurosurg 2002;97:370-387.
[PubMed]
46.
De Salles AAF, Frighetto L, Behnke E, Sinha S, Tseng L, Torres R, Lee M, Cabatan-Awang C, Frysinger R: Functional neurosurgery in the MRI environment. Minim Invas Neurosur 2004;47:284-289.
[PubMed]
47.
Andrade-Souza YM, Schwalb JM, Hamani C, Eltahawy H, Hoque T, Saint-Cyr J, Lozano AM: Comparison of three methods of targeting the subthalamic nucleus for chronic stimulation in Parkinson's disease. Neurosurgery 2005;56:360-368.
[PubMed]
48.
Lee MWY, De Salles AAF, Frighetto L, Torres R, Behnke E, Bronstein JM: Deep brain stimulation in intraoperative MRI environment - comparison of imaging techniques and electrode fixation methods. Minim Invas Neurosurg 2005;48:1-6.
[PubMed]
49.
Guo T, Parrent A, Peters T: Surgical targeting accuracy analysis of six methods for subthalamic nucleus deep brain stimulation. Comput Aided Surg 2007;12:325-334.
[PubMed]
50.
Pezeshkian P, DeSalles AA, Gorgulho A, Behnke E, McArthur D, Bari A: Accuracy of frame-based stereotactic magnetic resonance imaging vs frame-based stereotactic head computed tomography fused with recent magnetic resonance imaging for postimplantation deep brain stimulator lead localization. Neurosurgery 2011;69:1299-1306.
[PubMed]
51.
Chang WS, Kim HY, Kim JP, Park YS, Chung SS, Chang JW: Bilateral subthalamic deep brain stimulation using single track microelectrode recording. Acta Neurochir (Wien) 2011;153:1087-1095.
[PubMed]
52.
Foltynie T, Zrinzo L, Martinez-Torres I, Tripoliti E, Petersen E, Holl E, Aviles-Olmos I, Jahanshahi M, Hariz M, Limousin P: MRI-guided STN DBS in Parkinson's disease without microelectrode recording: efficacy and safety. J Neurol Neurosurg Psychiatry 2011;82:358-363.
[PubMed]
53.
Mirzadeh Z, Chapple K, Lambert M, Dhall R, Ponce FA: Validation of CT-MRI fusion for intraoperative assessment of stereotactic accuracy in DBS surgery. Mov Disord 2014;29:1788-1795.
[PubMed]
54.
Larson PS, Starr PA, Bates G, Tansey L, Richardson RM, Martin AJ: An optimized system for interventional magnetic resonance imaging-guided stereotactic surgery: preliminary evaluation of targeting accuracy. Neurosurgery 2012;70:95-103.
[PubMed]
55.
Simon SL, Douglas P, Baltuch GH, Jaggi JL: Error analysis of MRI and Leksell stereotactic frame target localization in deep brain stimulation surgery. Stereotact Funct Neurosurg 2005;83:1-5.
[PubMed]
56.
O'Gorman RL, Jarosz JM, Samuel M, Clough C, Selway RP, Ashkan K: CT/MR image fusion in the postoperative assessment of electrodes implanted for deep brain stimulation. Stereotact Funct Neurosurg 2009;87:205-210.
[PubMed]
57.
Lee JY, Kim JW, Lee JY, Lim YH, Kim C, Kim DG, Jeon BS, Paek SH: Is MRI a reliable tool to locate the electrode after deep brain stimulation surgery? Comparison study of CT and MRI for the localization of electrodes after DBS. Acta Neurochir (Wien) 2010;152:2029-2036.
[PubMed]
58.
Balachandran R, Welch EB, Dawant BM, Fitzpatrick JM: Effect of MR distortion on targeting for deep-brain stimulation. IEEE Trans Biomed Eng 2010;57:1729-1735.
[PubMed]
59.
Sauner D, Runge M, Poggenborg J, Maarouf M, Sturm V, Treuer H, Hunsche S: Multimodal localization of electrodes in deep brain stimulation: comparison of stereotactic CT and MRI with teleradiography. Stereotact Funct Neurosurg 2010;88:253-258.
[PubMed]
60.
Pinsker MO, Herzog J, Falk D, Volkmann J, Deuschl G, Mehdorn M: Accuracy and distortion of deep brain stimulation electrodes on postoperative MRI and CT. Zentralbl Neurochir 2008;69:144-147.
[PubMed]
61.
Li G, Su H, Cole G, Shang W, Harrington K, Camilo A, Pilitsis J, Fischer G: Robotic system for MRI-guided stereotactic neurosurgery. IEEE Trans Biomed Eng 2015;62:1077-1088.
[PubMed]
62.
Thani NB, Bala A, Swann GB, Lind CR: Accuracy of postoperative computed tomography and magnetic resonance image fusion for assessing deep brain stimulation electrodes. Neurosurgery 2011;69:207-214.
[PubMed]
63.
Slotty PJ, Kamp MA, Wille C, Kinfe TM, Steiger HJ, Vesper J: The impact of brain shift in deep brain stimulation surgery: observation and obviation. Acta Neurochir (Wien) 2012;154:2063-2068.
[PubMed]
64.
Lalys F, Haegelen C, D'Albis T, Jannin P: Analysis of electrode deformations in deep brain stimulation surgery. Int J Comput Assist Radiol Surg 2014;9:107-117.
[PubMed]
65.
Contarino MF, Bot M, Speelman JD, de Bie RM, Tijssen MA, Denys D, Bour LJ, Schuurman PR, van den Munckhof P: Postoperative displacement of deep brain stimulation electrodes related to lead-anchoring technique. Neurosurgery 2013;73:681-688.
[PubMed]
66.
van den Munckhof P, Contarino MF, Bour LJ, Speelman JD, de Bie RM, Schuurman PR: Postoperative curving and upward displacement of deep brain stimulation electrodes caused by brain shift. Neurosurgery 2010;67:49-53.
[PubMed]
67.
Balachandran R, Fritz MA, Dietrich MS, Danilchenko A, Mitchell JE, Oldfield VL, Lipscomb WW, Fitzpatrick JM, Neimat JS, Konrad PE, Labadie RF: Clinical testing of an alternate method of inserting bone-implanted fiducial markers. Int J Comput Assist Radiol Surg 2014;9:913-920.
[PubMed]
68.
Wharen RE Jr, Putzke JD, Uitti RJ: Deep brain stimulation lead fixation: a comparative study of the Navigus and Medtronic burr hole fixation device. Clin Neurol Neurosurg 2005;107:393-395.
[PubMed]
69.
Pepper J, Zrinzo L, Mirza B, Foltynie T, Limousin P, Hariz M: The risk of hardware infection in deep brain stimulation surgery is greater at impulse generator replacement than at the primary procedure. Stereotact Funct Neurosurg 2013;91:56-65.
[PubMed]
70.
Parittotokkaporn T, Thomas DG, Schneider A, Huq E, Davies BL, Degenaar P, Rodriguez y Baena F: Microtextured surfaces for deep-brain stimulation electrodes: a biologically inspired design to reduce lead migration. World Neurosurg 2012;77:569-576.
[PubMed]
71.
Gross RE, Krack P, Rodriguez-Oroz MC, Rezai AR, Benabid AL: Electrophysiological mapping for the implantation of deep brain stimulators for Parkinson's disease and tremor. Mov Disord 2006;21:S259-S283.
[PubMed]
72.
Montgomery EB Jr: Microelectrode targeting of the subthalamic nucleus for deep brain stimulation surgery. Mov Disord 2012;27:1387-1391.
[PubMed]
73.
Shamir RR, Zaidel A, Joskowicz L, Bergman H, Israel Z: Microelectrode recording duration and spatial density constraints for automatic targeting of the subthalamic nucleus. Stereotact Funct Neurosurg 2012;90:325-334.
[PubMed]
74.
Carlson JD, Iacono RP: Electrophysiological versus image-based targeting in the posteroventral pallidotomy. Comput Aided Surg 1999;4:93-100.
[PubMed]
75.
Mobin F, De Salles AAF, Behnke EJ, Frysinger R: Correlation between MRI-based stereotactic thalamic deep brain stimulation electrode placement, macroelectrode stimulation and clinical response to tremor control. Stereotact Funct Neurosurg 1999;72:225-232.
[PubMed]
76.
Zrinzo L, Foltynie T, Limousin P, Hariz MI: Reducing hemorrhagic complications in functional neurosurgery: a large case series and systematic literature review. J Neurosurg 2012;116:84-94.
[PubMed]
77.
McClelland S: A cost analysis of intraoperative microelectrode recording during subthalamic stimulation for Parkinson's disease. Mov Disord 2011;26:1422-1427.
[PubMed]
You do not currently have access to this content.