Background: Postoperative imaging is essential for verifying electrode location in patients undergoing deep brain stimulation (DBS). MRI offers better visualisation of brain targets, but concerns about adverse events have limited its use. Preoperative stereotactic MRI fused with a postoperative stereotactic CT, demonstrating the electrode position, is now widely used. Objectives: The aims of this study were to: (1) evaluate the accuracy of image registration using Neuroinspire, and (2) undertake a systematic review of the literature on CT/MRI fusion techniques to ascertain the accuracy of other software packages. Methods: Twenty patients who underwent bilateral subthalamic nucleus DBS for Parkinson's disease were selected. The postoperative CT was registered and fused with the preoperative MRI using Neuroinspire. The position of each electrode tip was determined in stereotactic coordinates both in the (unfused) postoperative CT and the fused CT/MRI. The difference in tip position was used to evaluate the registration accuracy. Results: The mean error ± SD of CT/MRI fusion using Neuroinspire was 0.25 ± 0.15, 0.33 ± 0.26 and 0.46 ± 0.55 mm in lateral, anteroposterior and vertical axes. A systematic review suggested that CT/MRI registration with Neuroinspire is more accurate than that achieved with other tested CT/MRI fusion algorithms. Conclusion: CT/MRI fusion for localisation of electrode placement offers an accurate, reliable and safe modality for assessing electrode location.

1.
Poortvliet PC, Silburn PA, Coyne TJ, Chenery HJ: Deep brain stimulation for Parkinson disease in Australia: current scientific and clinical status. Intern Med J 2015;45:134-139.
2.
Silberstein P, Bittar RG, Boyle R, Cook R, Coyne T, O'Sullivan D, et al: Deep brain stimulation for Parkinson's disease: Australian referral guidelines. J Clin Neurosci 2009;16:1001-1008.
3.
National Institute for Health and Care Excellence: Deep brain stimulation for Parkinson's disease: NICE; 2003. https://www.nice.org.uk/guidance/ipg19/resources/guidance-deep-brain-stimulation-for-parkinsons-disease-pdf.
4.
Burchiel KJ, McCartney S, Lee A, Raslan AM: Accuracy of deep brain stimulation electrode placement using intraoperative computed tomography without microelectrode recording. J Neurosurg 2013;119:301-306.
5.
Barnaure I, Pollak P, Momjian S, Horvath J, Lovblad KO, Boex C, et al: Evaluation of electrode position in deep brain stimulation by image fusion (MRI and CT). Neuroradiology 2015;57:903-908.
6.
O'Gorman RL, Jarosz JM, Samuel M, Clough C, Selway RP, Ashkan K: CT/MR image fusion in the postoperative assessment of electrodes implanted for deep brain stimulation. Stereotact Funct Neurosurg 2009;87:205-210.
7.
Ferroli P, Franzini A, Marras C, Maccagnano E, D'Incerti L, Broggi G: A simple method to assess accuracy of deep brain stimulation electrode placement: pre-operative stereotactic CT + postoperative MR image fusion. Stereotact Funct Neurosurg 2004;82:14-19.
8.
Thani NB, Bala A, Swann GB, Lind CR: Accuracy of postoperative computed tomography and magnetic resonance image fusion for assessing deep brain stimulation electrodes. Neurosurgery 2011;69:207-214; discussion 214.
9.
Tarsy D, Vitek JL, Starr P, Okun M: Deep Brain Stimulation in Neurological and Psychiatric Disorders. New York, Humana Press, 2008, p 379.
10.
Okun MS, Fernandez HH, Wu SS, Kirsch-Darrow L, Bowers D, Bova F, Suelter M, Jacobson CE, Wang X, Gordon CW, Zeilman P, Romrell J, Martin P, Ward H, Rodriguez RL, Foote KD: Cognition and mood in Parkinson disease in STN versus GPi DBS: the COMPARE Trial. Ann Neurol 2009;65:586-595.
11.
Rezai AR, Finelli D, Nyenhuis JA, Hrdlicka G, Tkach J, Sharan A, et al: Neurostimulation systems for deep brain stimulation: in vitro evaluation of magnetic resonance imaging-related heating at 1.5 tesla. J Magn Reson Imaging 2002;15:241-250.
12.
Kahan J, Papadaki A, White M, Mancini L, Yousry T, Zrinzo L, et al: The safety of using body-transmit MRI in patients with implanted deep brain stimulation devices. PLoS One 2015;10:e0129077.
14.
Toms AP, Smith-Bateman C, Malcolm PN, Cahir J, Graves M: Optimization of metal artefact reduction (MAR) sequences for MRI of total hip prostheses. Clin Radiol 2010;65:447-452.
15.
Sarkar SN, Sarkar PR, Papavassiliou E, Rojas RR: Utilizing fast spin echo MRI to reduce image artifacts and improve implant/tissue interface detection in refractory Parkinson's patients with deep brain stimulators. Parkinsons Dis 2014;2014:508576.
16.
Larson PS, Richardson RM, Starr PA, Martin AJ: Magnetic resonance imaging of implanted deep brain stimulators: experience in a large series. Stereotact Funct Neurosurg 2008;86:92-100.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.