Background: Deep brain stimulation (DBS) is recognized as an effective treatment for movement disorders. We recently changed our technique, limiting the number of brain penetrations to three per side. Objectives: The first aim was to evaluate the electrode precision on both sides of surgery since we implemented this surgical technique. The second aim was to analyse whether or not the electrode placement was improved with microrecording and macrostimulation. Methods: We retrospectively reviewed operation protocols and MRIs of 30 patients who underwent bilateral DBS. For microrecording and macrostimulation, we used three parallel channels of the ‘Ben Gun' centred on the MRI-planned target. Pre- and post-operative MRIs were merged. The distance between the planned target and the centre of the implanted electrode artefact was measured. Results: There was no significant difference in targeting precision on both sides of surgery. There was more intra-operative adjustment of the second electrode positioning based on microrecording and macrostimulation, which allowed to significantly approach the MRI-planned target on the medial-lateral axis. Conclusion: There was more electrode adjustment needed on the second side, possibly in relation with brain shift. We thus suggest performing a single central track with electrophysiological and clinical assessment, with multidirectional exploration on demand for suboptimal clinical responses.

1.
Halpern CH, Danish SF, Baltuch GH, Jaggi JL: Brain shift during deep brain stimulation surgery for Parkinson's disease. Stereotact Funct Neurosurg 2008;86:37-43.
2.
Elias WJ, Fu KM, Frysinger RC: Cortical and subcortical brain shift during stereotactic procedures. J Neurosurg 2007;107:983-988.
3.
Khan MF, Mewes K, Gross RE, Skrinjar O: Assessment of brain shift related to deep brain stimulation surgery. Stereotact Funct Neurosurg 2008;86:44-53.
4.
Nimsky C, Ganslandr O, Cerny S, Hastreiter P, Greiner G, Fahlbusch R: Quantification of, visualization of, and compensation for brain shift using intraoperative magnetic resonance imaging. Neurosurgery 2000;47:1070-1079.
5.
Huston OO, Watson RE, Bernstein MA, McGee KP, Stead SM, Gorman DA, Lee KH, Huston J: Intraoperative magnetic resonance imaging findings during deep brain stimulation surgery. J Neurosurg 2011;115:852-857.
6.
Cuny E, Guehl D, Burbaud P, Gross C, Dousset V, Rougier A: Lack of agreement between direct magnetic resonance imaging and statistical determination of a subthalamic target: the role of electrophysiological guidance. J Neurosurg 2002;97:591-597.
7.
Schlaier JR, Habermeyer D, Warnat J, Lange M, Janzen A, Hochreiter A, Proescholdt M, Brawanski A, Fellner C: Discrepancies between the MRI- and the electrophysiologically defined subthalamic nucleus. Acta Neurochir (Wien) 2011;153:2307-2318.
8.
Petersen EA, Holl EM, Martinez-Torres I, Foltynie T, Limousin P, Hariz MI, Zrinzo L: Minimizing brain shift in stereotactic functional neurosurgery. Neurosurgery 2010;67:213-221.
9.
Coenen VA, Abdel-Rahman A, McMaster J, Bogod N, Honey CR: Minimizing brain shift during functional neurosurgical procedures - a simple burr hole technique that can decrease CSF loss and intracranial air. Cent Eur Neurosurg 2011;72:181-185.
10.
Abosch A, Timmermann L, Bartley S, Rietkerk HG, Whiting D, Connolly PJ, Lanctin D, Hariz MI: An international survey of deep brain stimulation procedural steps. Stereotact Funct Neurosurg 2013;91:1-11.
11.
Pollo C, Meuli R, Maeder P, Vingerhoets F, Ghika J, Villemure JG: Subthalamic nucleus deep brain stimulation for Parkinson's disease: magnetic resonance imaging targeting using visible anatomical landmarks. Stereotact Funct Neurosurg 2003;80:76-81.
12.
Miyagi Y, Shima F, Sasaki T: Brain shift: an error factor during implantation of deep brain stimulation electrodes. J Neurosurg 2007;107:989-997.
13.
Hunsche S, Sauner D, Maaroud M, Poggenborg J, Lackner K, Sturm V, Treuer H: Intraoperative X-ray detection and MRI-based quantification of brain shift effects subsequent to implantation of the first electrode in bilateral implantation of deep brain stimulation electrodes. Stereotact Funct Neurosurg 2009;87:322-329.
14.
Winkler D, Tittgemeyer M, Schwarz J, Preul C, Strecker K, Meixensberger J: The first evaluation of brain shift during functional neurosurgery by deformation field analysis. J Neurol Neurosurg Psychiatry 2005;76:1161-1163.
15.
Derrey S, Lefaucheur R, Proust F, Chastan N, Lévèque S, Gérardin E, Fréger P, Maltête D: The unsuccessful placement of a deep brain stimulation electrode due to a brain shift induced by air invasion: case report. Parkinsonism Relat Disord 2011;17:393-394.
16.
Azmi H, Machado A, Deogaonkar M, Rezai A: Intracranial air correlates with preoperative cerebral atrophy and stereotactic error during bilateral STN DBS surgery for Parkinson's disease. Stereotact Funct Neurosurg 2011;89:246-252.
17.
Amirnovin R, Williams Z, Cosgrove G, Eskandar E: Experience with microelectrode guided subthalamic deep brain stimulation. Neurosurgery 2006;58(1 suppl):ONS96-ONS102; discussion ONS96-ONS102.
18.
Chrastina J, Novak Z, Balaz M, Riha I, Bockova M, Rektor I: The role of brain shift, patient age, and Parkinson's disease duration in the difference between anatomical and electrophysiological targets for subthalamic stimulation. Br J Neurosurg 2013;27:676-682.
19.
Priori A, Egidi M, Pesenti A, Rohr M, Rampini P, Locatelli M, Tamma F, Caputo E, Chiesa V, Barbieri S: Do intraoperative micorecordings improve subthalamic nucleus targeting in stereotactif neurosurgery for Parkinson's disease? J Neurosurg Sci 2003;47:56-60.
20.
Bour LJ, Contarino MF, Foncke EM, de Bie RM, Van den Munckhof P, Speelman JD, Schuurman PR: Long-term experience with intraoperative microrecording during DBS neurosurgery in STN and GPi. Acta Neurochir (Wien) 2010;152:2069-2077.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.