Background and Objective: Neuronavigation devices have progressed over the past 2 decades, but logistical limitations remain for many stereotactic procedures. We describe our technique and accuracy for a novel miniature optical tracking system which overcomes these limitations. Method: The minioptical tracking system uses a miniature video camera mounted on a rigid cannula to determine cannula location and orientation relative to a patient-attached sticker containing reference markers. A CT scan is used to register these markers to the anatomy and a user-selected target. A computer displays the cannula guidance information to the target. Bench testing was performed on 225 targets in a custom test phantom and additional testing was performed on 20 small targets in an anthropomorphic head phantom to determine the practical accuracy and workflow. Results: The phantom study demonstrated that 3-D navigation accuracy is 1.41 ± 0.53 mm. There was a 100% head phantom study success rate for the 20 small targets. Conclusions: The resulting accuracy data demonstrated good correlation with the CT data, and the clinical simulation workflow indicated its potential usefulness for common neurosurgical applications. Furthermore, this small-footprint tracking technology does not experience the traditional environmentally induced issues or the requirement of pin-based head fixation, allowing for use in the neurointensive care unit and the emergency department.

1.
Buchalla R, Hopf-Jensen S, Rubarth O, Börm W: Frameless navigated biopsy with the BrainLAB® VarioGuide system: a technical note. J Neurol Surg A Cent Eur Neurosurg 2013;74:321-324.
2.
Harrisson SE, Shooman D, Grundy PL: A prospective study of the safety and efficacy of frameless, pinless electromagnetic image-guided biopsy of cerebral lesions. Neurosurgery 2012;70(1 Suppl Operative):29-33.
3.
Raabe A, Krishnan R, Zimmermann M, Seifert V: Frame-less and frame-based stereotaxy? How to choose the appropriate procedure. Zentralbl Neurochir 2003;64:1-5.
4.
Owen CM, Linskey ME: Frame-based stereotaxy in a frameless era: current capabilities, relative role, and the positive- and negative predictive values of blood through the needle. J Neurooncol 2009;93:139-149.
5.
Hall WA, Liu H, Truwit CL: Navigus trajectory guide. Neurosurgery 2000;46:502-504.
6.
Grunert P, Charalampaki K, Kassem M, Boecher-Schwarz H, Filippi R, Grunert P Jr: Frame-based and frameless stereotaxy in the localization of cavernous angiomas. Neurosurg Rev 2003;26:53-61.
7.
Widmann G, Eisner W, Kovacs P, Fiegele T, Ortler M, Lang TB, Stoffner R, Bale R: Accuracy and clinical use of a novel aiming device for frameless stereotactic brain biopsy. Minim Invasive Neurosurg 2008;51:361-369.
8.
Thiex R, Rohde V, Rohde I, Mayfrank L, Zeki Z, Thron A, Gilsbach JM, Uhl E: Frame-based and frameless stereotactic hematoma puncture and subsequent fibrinolytic therapy for the treatment of spontaneous intracerebral hemorrhage. J Neurol 2004;251:1443-1450.
9.
Hummel J, Figl M, Kollmann C, Bergmannb H, Birkfellner W: Evaluation of a miniature electromagnetic position tracker. Med Phys 2002;29:2205-2212.
10.
von Jako RA, Carrino JA, Yonemura KS, Noda GA, Zhue W, Blaskiewicz D, Rajue M, Groszmann DE, Weber G: Electromagnetic navigation for percutaneous guide-wire insertion: accuracy and efficiency compared to conventional fluoroscopic guidance. Neuroimage 2009;47:T127-T132.
11.
Amin DV, Lozanne K, Parry PV, Engh JA, Seelman K, Mintz A: Image-guided frameless stereotactic needle biopsy in awake patients without the use of rigid head fixation. J Neurosurg 2011;114:1414-1420.
12.
von Jako C, Zuk Y, Zur O, Gilboa P: A novel accurate mini-optical tracking system for percutaneous needle placement. IEEE Trans Biomed Eng 2013, E-pub ahead of print.
13.
Giese H, Hoffmann KT, Winkelmann A, Stockhammer F, Jallo GI, Thomale UW: Precision of navigated stereotactic probe implantation into the brainstem. J Neurosurg Pediatr 2010;5:350-359.
14.
Rosenow JM, Sootsman WK: Application accuracy of an electromagnetic field-based image-guided navigation system. Stereotact Funct Neurosurg 2007;85:75-81.
15.
Ghajar JB: A guide for ventricular catheter placement. Technical note. J Neurosurg 1985;63:985-986.
16.
O'Leary ST, Kole MK, Hoover DA, Hysell SE, Thomas A, Shaffrey CI: Efficacy of the Ghajar Guide revisited: a prospective study. J Neurosurg 2000;92:801-803.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.