Background: Neurosurgeons regularly plan their surgery using magnetic resonance imaging (MRI) images, which may show a clear distinction between the area to be resected and the surrounding healthy brain tissue depending on the nature of the pathology. However, this distinction is often unclear with the naked eye during the surgical intervention, and it may be difficult to infer depth and an accurate volumetric interpretation from a series of MRI image slices. Objectives: In this work, MRI data are used to create affordable patient-specific 3-dimensional (3D) scale models of the brain which clearly indicate the location and extent of a tumour relative to brain surface features and important adjacent structures. Methods: This is achieved using custom software and rapid prototyping. In addition, functionally eloquent areas identified using functional MRI are integrated into the 3D models. Results: Preliminary in vivo results are presented for 2 patients. The accuracy of the technique was estimated both theoretically and by printing a geometrical phantom, with mean dimensional errors of less than 0.5 mm observed. Conclusions: This may provide a practical and cost-effective tool which can be used for training, and during neurosurgical planning and intervention.

1.
Rengier F, von Tengg-Kobligk H, Zechmann C, Kauczor HU, Giesel FL: Beyond the eye - medical applications of 3D rapid prototyping objects. Eur Med Imaging Rev 2008;1:76-80.
2.
Tharin S, Golby A: Neurosurgical treatment planning; in Newton HB, Jolesz FA (eds): Handbook of Neuro-Oncology Neuroimaging. New York, Academic Press, 2008, pp 181-191.
3.
Kettenbach J, Wong T, Kacher D, Hata N, Schwartz RB, Black P McL, Kikinis R, Jolesz FA: Computer-based imaging and interventional MRI: applications for neurosurgery. Comput Med Imaging Graph 1999;23:245-258.
4.
Hirsch J, Ruge MI, Kim KHS, Correa DD, Victor JD, Relkin NR, Labar DR, Krol G, Bilsky MH, Souweidane MM, DeAngelis LM, Gutin PH: An integrated functional magnetic resonance imaging procedure for preoperative mapping of cortical areas associated with tactile, motor, language, and visual functions. Neurosurgery 2000;47:711-722.
5.
Geerts J, Martens M, Vandevenne JE, Gelin G, Grieten M, Weyns F, Stinissen P, Palmers Y, Wuyts J: Functional magnetic resonance imaging for preoperative localisation of eloquent brain areas relative to brain tumours: clinical implementation in a regional hospital. JBR-BTR 2007;90:258-263.
6.
Swann S: Integration of MRI and stereolithography to build medical models: a case study. Rapid Prototyping J 1996;2:41-46.
7.
Berry E, Brown JM, Connell M, Craven CM, Efford ND, Radjenovic A, Smith MAS: Preliminary experience with medical applications of rapid prototyping by selective laser sintering. Med Eng Phys 1997;19:90-96.
8.
Foroutan M, Fallahi B, Mottavalli S, Du-jovny M: Stereolithography: application to neurosurgery. Crit Rev Neurosurg 1998;8:203-208.
9.
McGurk M, Potamianos P, Amis AA, Goodger NM: Rapid prototyping techniques for anatomical modelling in medicine. Ann R Coll Surg Engl 1997;79:169-174.
10.
Kai CC, Meng CS, Ching LS, Hoe EK, Fah LK: Rapid prototyping assisted surgery planning. Int J Adv Manuf Technol 1998;14:624-630.
11.
Webb PA: A review of rapid prototyping (RP) techniques in the medical and biomedical sector. J Med Eng Technol 2000;24:149-153.
12.
Müller A, Krishnan KG, Uhl E, Mast G: The application of rapid prototyping technologies in cranial reconstruction and preoperative planning in neurosurgery. J Craniofac Surg 2003;14:899-914.
13.
Cunningham Jr LL, Madsen MJ, Peterson G: Stereolithographic modeling technology applied to tumor resection. J Oral Maxillofac Surg 2005;63:873-878.
14.
Waran V, Devaraj P, Hari Chandran T, Muthusamy KA, Rathinam AK, Balakrishnan YK, Tung TS, Raman R, Rahman ZAA: Three-dimensional anatomical accuracy of cranial models created by rapid prototyping techniques validated using a neuronavigation station. J Clin Neurosci 2012;19:574-577.
15.
Winder J, Bibb R: Medical rapid prototyping technologies: state of the art and current limitations for applications in oral and maxillofacial surgery. J Oral Maxillofac Surg 2005;63:1006-1015.
16.
Yu CS, Li KC, Xuan Y, Ji XM, Qin W: Diffusion tensor tractography in patients with cerebral tumors: a helpful technique for neurosurgical planning and postoperative assessment. Eur J Radiol 2005;56:197-204.
17.
Acevedo D, Zhang S, Laidlaw DH, Bull CW: Color rapid prototyping for diffusion tensor MRI visualization. Proc MICCAI, Saint-Malo, September 2004, pp 1076-1078.
18.
Markl M, Schumacher R, Küffer J, Bley TA, Hennig J: Rapid vessel prototyping: vascular modeling using 3T magnetic resonance angiography and rapid prototyping technology. MAGMA 2005;18:288-292.
19.
Mugler JP III, Brookeman JR: Three-dimensional magnetization-prepared rapid gradient-echo imaging (3D MP RAGE). Magn Reson Med 1990;15:152-157.
20.
Smith SM, Jenkinson M, Woolrich MW, Beckmann CF, Behrens TEJ, Johansen-Berg H, Bannister PR, De Luca M, Drobnjak I, Flitney DE, et al: Advances in functional and structural MR image analysis and implementation as FSL. Neuroimage 2004;23:208-219.
21.
Hahn HK, Link F, Peitgen H: Concepts for rapid application prototyping in medical image analysis and visualization. Proc Simulation Visualisierung, Ghent, March 2003, pp 283-298.
22.
Janke A, Zhao H, Cowin GJ, Galloway GJ, Doddrell GM: Use of spherical harmonic deconvolution methods to compensate for nonlinear gradient effects on MRI images. Magn Reson Med 2004;52:115-122.
23.
Jezzard P, Balaban RS: Correction for geometric distortion in echo planar images from B0 field variations. Magn Reson Med 1995;34:65-73.
24.
Chang PS, Patrick TH, Patrick CW Jr, Miller MJ: The accuracy of stereolithography in planning craniofacial bone replacement. J Craniofac Surg 2003;14:164-170.
25.
Silva DN, Gerhardt de Oliveira M, Meurer E, Meurer MI, Lopes da Silva JV, Santa-Barbara A: Dimensional error in selective laser sintering and 3D-printing of models for craniomaxillary anatomy reconstruction. J Cra-niomaxillofac Surg 2008;36:443-449.
26.
Fengqiang L, Jiadong Q, Yi L: Computer-assisted stereotactic neurosurgery with framework neurosurgery navigation. Clin Neurol Neurosurg 2008;110:696-700.
27.
Hastreiter P, Rezk-Salama C, Soza G, Bauer M, Greiner G, Fahlbusch R, Ganslandt O, Nimsky C: Strategies for brain shift evaluation. Med Image Anal 2004;8:447-464.
28.
Kalejs M, von Segesser LK: Rapid prototyping of compliant human aortic roots for assessment. Interact Cardiovasc Thorac Surg 2008;8:182-186.
29.
Taft RM, Kondor S, Grant GT: Accuracy of rapid prototype models for head and neck reconstruction. J Prosthet Dent 2011;106:399-408.
30.
Faber J, Berto PM, Quaresma M: Rapid prototyping as a tool for diagnosis and treatment planning for maxillary canine impaction. Am J Orthod Dentofacial Orthop 2006;129:583-589.
31.
Mironov V, Boland T, Trusk T, Forgacs G, Markwald RR: Organ printing: computer-aided jet-based 3D tissue engineering. Trends Biotechnol 2003;21:157-161.
32.
Mironov V, Visconti RP, Kasyanov V, Forgacs G, Drake CJ, Markwald RR: Organ printing: tissue spheroids as building blocks. Biomaterials 2009;30:2164-2174.
33.
Mironov V, Kasyanov V, Markwald RR: Organ printing: from bioprinter to organ biofabrication line. Curr Opin Biotechnol 2011;22:667-673.
34.
Fischl B, Salat DH, Busa E, Albert M, Die-terich M, Haselgrove C, van der Kouwe A, Killiany R, Kennedy D, Klaveness S, Montillo A, Makris N, Rosen B, Dale AM: Whole brain segmentation: automated labelling of neuroanatomical structures in the human brain. Neuron 2002;33:341-355.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.