Background/Aims: Stereotactic postoperative imaging is essential for verification of the position of electrodes implanted for deep brain stimulation (DBS). MRI offers superior visualisation of the DBS targets relative to CT, but previous adverse incidents have heightened concerns about risks of postoperative MRI. Preoperative MRI fused with postoperative CT offers an alternative method for evaluating electrode position, but before this method can be clinically applied, the image registration accuracy must be established. The purpose of this study was to quantitatively assess the accuracy of three different image registration and fusion methods. Methods: Preoperative stereotactic MRI and postoperative stereotactic CT were acquired from 20 patients under- going DBS surgery (35 electrodes in total). The postoperative CT was registered and fused with the preoperative MRI, using three different registration algorithms. The position of each electrode tip was determined in stereotactic coordinates both in the (unfused) postoperative CT and the fused CT/MRI. The difference in tip position between the CT and fused CT/MRI was used to evaluate the registration accuracy. Results: The mean error along the lateral, anteroposterior, and vertical axes was 0.5, 0.5, and 1 mm, respectively. Conclusions: CT/MRI fusion provides a safe, practical technique for postoperative identification of DBS electrodes.

This content is only available via PDF.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.