Background: Occipital nerve stimulation is being used for various pain syndromes. Here, we expand its use for the treatment of refractory occipital pain after occipitocervical fusion. Case Description: We describe a case of occipital neuralgia in a 60-year-old man following posterior occipitocervical fusion. The maximum pain intensity was rated 9/10 on the visual analogue scale (VAS). Since pain proved to be refractory to analgetic medication, two quadripolar electrodes (Resume II, Medtronic) were implanted in the occipital region to stimulate the occipital nerve bilaterally. The patient experienced a dramatic response during test stimulation for 10 days with externalized electrodes, and a pacemaker (Synergy, Medtronic) was connected to the electrodes. While on chronic stimulation (bipolar 6 V, 210 μs, 130 Hz) improvement of pain was maintained, reflected by a decrease in the VAS score to 1/10 at 12 months of follow-up. Conclusion: Occipital nerve stimulation for medical refractory occipital neuralgia after occipitocervical fusion is an effective method expanding the indications for its use.

This content is only available via PDF.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.