Background: This study evaluated the CyberKnife frameless image-guided radiosurgery system for the treatment of spinal lesions. Methods: This system utilizes the coupling of an orthogonal pair of X-ray cameras to a dynamically manipulated robot-mounted linear accelerator that guides the therapy beam to the intended target without the use of frame-based fixation. Cervical spine lesions are located and tracked relative to skull bony landmarks; lower spinal lesions are tracked relative to fiducial markers. 125 spinal lesions in 115 consecutive patients were treated with a single-fraction radiosurgery technique. Results: Tumor volume ranged from 0.3 to 232 ml (mean 27.8 ml). Tumor radiation dose was maintained at 12–20 Gy to the 80% isodose line (mean 14 Gy); the spinal cord or canal volume receiving greater than 8 Gy ranged from 0.0 to 1.7 ml (mean 0.2 ml). No acute radiation toxicity or new neurological deficits occurred during the follow-up period (3–24 months). Conclusions: The CyberKnife system was found to be feasible, safe and effective. The major potential benefits of radiosurgical ablation of spinal lesions are short treatment time in an outpatient setting with rapid recovery and good response.

This content is only available via PDF.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.