Introduction: Deep brain stimulation (DBS) is a routine neurosurgical procedure utilized to treat various movement disorders including Parkinson’s disease (PD), essential tremor (ET), and dystonia. Treatment efficacy is dependent on stereotactic accuracy of lead placement into the deep brain target of interest. However, brain shift attributed to pneumocephalus can introduce unpredictable inaccuracies during DBS lead placement. This study aimed to determine whether intracranial air is associated with brain shift in patients undergoing staged DBS surgery. Methods: We retrospectively evaluated 46 patients who underwent staged DBS surgery for PD, ET, and dystonia. Due to the staged nature of DBS surgery at our institution, the first electrode placement is used as a concrete fiducial marker for movement in the target location. Postoperative computed tomography (CT) images after the first electrode implantation, as well as preoperative, and postoperative CT images after the second electrode implantation were collected. Images were analyzed in stereotactic targeting software (BrainLab); intracranial air was manually segmented, and electrode shift was measured in the x, y, and z plane, as well as a Euclidian distance on each set of merged CT scans. A Pearson correlation analysis was used to determine the relationship between intracranial air and brain shift, and student’s t test was used to compare means between patients with and without radiographic evidence of intracranial air. Results: Thirty-six patients had pneumocephalus after the first electrode implantation, while 35 had pneumocephalus after the second electrode implantation. Accumulation of intracranial air following the first electrode implantation (4.49 ± 6.05 cm3) was significantly correlated with brain shift along the y axis (0.04 ± 0.35 mm; r (34) = 0.36; p = 0.03), as well as the Euclidean distance of deviation (0.57 ± 0.33 mm; r (34) = 0.33; p = 0.05) indicating statistically significant shift on the ipsilateral side. However, there was no significant correlation between intracranial air and brain shift following the second electrode implantation, suggesting contralateral shift is minimal. Furthermore, there was no significant difference in brain shift between patients with and without radiographic evidence of intracranial air following both electrode implantation surgeries. Conclusion: Despite observing volumes as high as 22.0 cm3 in patients with radiographic evidence of pneumocephalus, there was no significant difference in brain shift when compared to patients without pneumocephalus. Furthermore, the mean magnitude of brain shift was <1.0 mm regardless of whether pneumocephalus was presenting, suggesting that intracranial air accumulation may not produce clinical significant brain shift in our patients.

1.
Krauss
JK
,
Lipsman
N
,
Aziz
T
,
Boutet
A
,
Brown
P
,
Chang
JW
, et al
.
Technology of deep brain stimulation: current status and future directions
.
Nat Rev Neurol
.
2021
;
17
(
2
):
75
87
.
2.
Khan
MF
,
Mewes
K
,
Gross
RE
,
Skrinjar
O
.
Assessment of brain shift related to deep brain stimulation surgery
.
Stereotact Funct Neurosurg
.
2008
;
86
(
1
):
44
53
.
3.
Kopell
BH
,
Rezai
AR
,
Chang
JW
,
Vitek
JL
.
Anatomy and physiology of the basal ganglia: implications for deep brain stimulation for Parkinson’s disease
.
Mov Disord
.
2006
;
21
(
Suppl 14
):
S238
46
.
4.
Lozano
CS
,
Ranjan
M
,
Boutet
A
,
Xu
DS
,
Kucharczyk
W
,
Fasano
A
, et al
.
Imaging alone versus microelectrode recording-guided targeting of the STN in patients with Parkinson’s disease
.
J Neurosurg
.
2019
;
130
:
1847
52
.
5.
Aviles-Olmos
I
,
Kefalopoulou
Z
,
Tripoliti
E
,
Candelario
J
,
Akram
H
,
Martinez-Torres
I
, et al
.
Long-term outcome of subthalamic nucleus deep brain stimulation for Parkinson’s disease using an MRI-guided and MRI-verified approach
.
J Neurol Neurosurg Psychiatry
.
2014
;
85
(
12
):
1419
25
.
6.
Boutet
A
,
Gramer
R
,
Steele
CJ
,
Elias
GJB
,
Germann
J
,
Maciel
R
, et al
.
Neuroimaging technological advancements for targeting in functional neurosurgery
.
Curr Neurol Neurosci Rep
.
2019
;
19
(
7
):
42
.
7.
Schulder
M
,
Mishra
A
,
Mammis
A
,
Horn
A
,
Boutet
A
,
Blomstedt
P
, et al
.
Advances in technical aspects of deep brain stimulation surgery
.
Stereotact Funct Neurosurg
.
2023
;
101
(
2
):
112
34
.
8.
Mehrkens
JH
,
Bötzel
K
,
Steude
U
,
Zeitler
K
,
Schnitzler
A
,
Sturm
V
, et al
.
Long-term efficacy and safety of chronic globus pallidus internus stimulation in different types of primary dystonia
.
Stereotact Funct Neurosurg
.
2009
;
87
(
1
):
8
17
.
9.
Foltynie
T
,
Zrinzo
L
,
Martinez-Torres
I
,
Tripoliti
E
,
Petersen
E
,
Holl
E
, et al
.
MRI-guided STN DBS in Parkinson’s disease without microelectrode recording: efficacy and safety
.
J Neurol Neurosurg Psychiatry
.
2011
;
82
(
4
):
358
63
.
10.
Maciunas
RJ
,
Galloway
RL
Jr
,
Latimer
JW
.
The application accuracy of stereotactic frames
.
Neurosurgery
.
1994
;
35
(
4
):
682
94
; discussion 694-5.
11.
Fitzpatrick
JM
,
West
JB
.
The distribution of target registration error in rigid-body point-based registration
.
IEEE Trans Med Imaging
.
2001
;
20
(
9
):
917
27
.
12.
Yu
C
,
Petrovich
Z
,
Apuzzo
ML
,
Luxton
G
.
An image fusion study of the geometric accuracy of magnetic resonance imaging with the Leksell stereotactic localization system
.
J Appl Clin Med Phys
.
2001
;
2
(
1
):
42
50
.
13.
Choi
KS
,
Noecker
AM
,
Riva-Posse
P
,
Rajendra
JK
,
Gross
RE
,
Mayberg
HS
, et al
.
Impact of brain shift on subcallosal cingulate deep brain stimulation
.
Brain Stimul
.
2018
;
11
(
2
):
445
53
.
14.
Wester
K
,
Kråkenes
J
.
Vertical displacement of the brain and the target area during open stereotaxic neurosurgery
.
Acta Neurochir
.
2001
;
143
(
6
):
603
6
.
15.
Winkler
D
,
Tittgemeyer
M
,
Schwarz
J
,
Preul
C
,
Strecker
K
,
Meixensberger
J
.
The first evaluation of brain shift during functional neurosurgery by deformation field analysis
.
J Neurol Neurosurg Psychiatry
.
2005
;
76
(
8
):
1161
3
.
16.
Miyagi
Y
,
Shima
F
,
Sasaki
T
.
Brain shift: an error factor during implantation of deep brain stimulation electrodes
.
J Neurosurg
.
2007
;
107
(
5
):
989
97
.
17.
Halpern
CH
,
Danish
SF
,
Baltuch
GH
,
Jaggi
JL
.
Brain shift during deep brain stimulation surgery for Parkinson’s disease
.
Stereotact Funct Neurosurg
.
2008
;
86
(
1
):
37
43
.
18.
Beggio
G
,
Raneri
F
,
Rustemi
O
,
Scerrati
A
,
Zambon
G
,
Piacentino
M
.
Techniques for pneumocephalus and brain shift reduction in DBS surgery: a review of the literature
.
Neurosurg Rev
.
2020
;
43
(
1
):
95
9
.
19.
Göransson
N
,
Johansson
JD
,
Wårdell
K
,
Zsigmond
P
.
Postoperative lead movement after deep brain stimulation surgery and the change of stimulation volume
.
Stereotact Funct Neurosurg
.
2021
;
99
(
3
):
221
9
.
20.
Ivan
ME
,
Yarlagadda
J
,
Saxena
AP
,
Martin
AJ
,
Starr
PA
,
Sootsman
WK
, et al
.
Brain shift during bur hole-based procedures using interventional MRI
.
J Neurosurg
.
2014
;
121
(
1
):
149
60
.
21.
Petraglia
FW
3rd
,
Farber
SH
,
Han
JL
,
Verla
T
,
Gallis
J
,
Lokhnygina
Y
, et al
.
Comparison of bilateral vs. Staged unilateral deep brain stimulation (DBS) in Parkinson’s disease in patients under 70 Years of age
.
Neuromodulation
.
2016
;
19
(
1
):
31
7
.
22.
Peng
S
,
Levine
D
,
Ramirez-Zamora
A
,
Chockalingam
A
,
Feustel
PJ
,
Durphy
J
, et al
.
A comparison of unilateral deep brain stimulation (DBS), simultaneous bilateral DBS, and staged bilateral DBS lead accuracies
.
Neuromodulation
.
2017
;
20
(
5
):
478
83
.
23.
Pezeshkian
P
,
DeSalles
AA
,
Gorgulho
A
,
Behnke
E
,
McArthur
D
,
Bari
A
.
Accuracy of frame-based stereotactic magnetic resonance imaging vs frame-based stereotactic head computed tomography fused with recent magnetic resonance imaging for postimplantation deep brain stimulator lead localization
.
Neurosurgery
.
2011
;
69
(
6
):
1299
306
.
24.
Kramer
DR
,
Halpern
CH
,
Buonacore
DL
,
McGill
KR
,
Hurtig
HI
,
Jaggi
JL
, et al
.
Best surgical practices: a stepwise approach to the University of Pennsylvania deep brain stimulation protocol
.
Neurosurg Focus
.
2010
;
29
(
2
):
E3
.
25.
Machado
A
,
Rezai
AR
,
Kopell
BH
,
Gross
RE
,
Sharan
AD
,
Benabid
AL
.
Deep brain stimulation for Parkinson’s disease: surgical technique and perioperative management
.
Mov Disord
.
2006
;
21
(
Suppl 14
):
S247
58
.
26.
Matias
CM
,
Frizon
LA
,
Asfahan
F
,
Uribe
JD
,
Machado
AG
.
Brain shift and pneumocephalus assessment during frame-based deep brain stimulation implantation with intraoperative magnetic resonance imaging
.
Oper Neurosurg
.
2018
;
14
(
6
):
668
74
.
27.
Elias
WJ
,
Fu
KM
,
Frysinger
RC
.
Cortical and subcortical brain shift during stereotactic procedures
.
J Neurosurg
.
2007
;
107
(
5
):
983
8
.
28.
Slotty
PJ
,
Kamp
MA
,
Wille
C
,
Kinfe
TM
,
Steiger
HJ
,
Vesper
J
.
The impact of brain shift in deep brain stimulation surgery: observation and obviation
.
Acta Neurochir
.
2012
;
154
(
11
):
2063
8
; discussion 2068.
29.
Krauss
P
,
Van Niftrik
CHB
,
Muscas
G
,
Scheffler
P
,
Oertel
MF
,
Stieglitz
LH
.
How to avoid pneumocephalus in deep brain stimulation surgery? Analysis of potential risk factors in a series of 100 consecutive patients
.
Acta Neurochir
.
2021
;
163
(
1
):
177
84
.
30.
Fan
S
,
Zhang
Q
,
Meng
F
,
Fang
H
,
Yang
G
,
Shi
Z
, et al
.
Comparison of dural puncture and dural incision in deep brain stimulation surgery: a simple but worthwhile technique modification
.
Front Neurosci
.
2022
;
16
:
988661
.
31.
van den Munckhof
P
,
Contarino
MF
,
Bour
LJ
,
Speelman
JD
,
de Bie
RM
,
Schuurman
PR
.
Postoperative curving and upward displacement of deep brain stimulation electrodes caused by brain shift
.
Neurosurgery
.
2010
;
67
(
1
):
49
53
; discussion 53-4.
32.
Sillay
KA
,
Kumbier
LM
,
Ross
C
,
Brady
M
,
Alexander
A
,
Gupta
A
, et al
.
Perioperative brain shift and deep brain stimulating electrode deformation analysis: implications for rigid and non-rigid devices
.
Ann Biomed Eng
.
2013
;
41
(
2
):
293
304
.
33.
Kremer
NI
,
van Laar
T
,
Lange
SF
,
Statius Muller
S
,
la Bastide-van Gemert
S
,
Oterdoom
DM
, et al
.
STN-DBS electrode placement accuracy and motor improvement in Parkinson’s disease: systematic review and individual patient meta-analysis
.
J Neurol Neurosurg Psychiatry
.
2023
;
94
(
3
):
236
44
.
34.
Starr
PA
,
Martin
AJ
,
Ostrem
JL
,
Talke
P
,
Levesque
N
,
Larson
PS
.
Subthalamic nucleus deep brain stimulator placement using high-field interventional magnetic resonance imaging and a skull-mounted aiming device: technique and application accuracy
.
J Neurosurg
.
2010
;
112
(
3
):
479
90
.
35.
Richardson
RM
,
Ostrem
JL
,
Starr
PA
.
Surgical repositioning of misplaced subthalamic electrodes in Parkinson’s disease: location of effective and ineffective leads
.
Stereotact Funct Neurosurg
.
2009
;
87
(
5
):
297
303
.
36.
Koeglsperger
T
,
Palleis
C
,
Hell
F
,
Mehrkens
JH
,
Bötzel
K
.
Deep brain stimulation programming for movement disorders: current concepts and evidence-based strategies
.
Front Neurol
.
2019
;
10
:
410
.
37.
Li
Z
,
Zhang
JG
,
Ye
Y
,
Li
X
.
Review on factors affecting targeting accuracy of deep brain stimulation electrode implantation between 2001 and 2015
.
Stereotact Funct Neurosurg
.
2016
;
94
(
6
):
351
62
.
38.
Hart
MG
,
Posa
M
,
Buttery
PC
,
Morris
RC
.
Increased variance in second electrode accuracy during deep brain stimulation and its relationship to pneumocephalus, brain shift, and clinical outcomes: a retrospective cohort study
.
Brain Spine
.
2022
;
2
:
100893
.
39.
Park
SC
,
Lee
JK
,
Kim
SM
,
Choi
EJ
,
Lee
CS
.
Systematic stereotactic error reduction using a calibration technique in single-brain-pass and multitrack deep brain stimulations
.
Oper Neurosurg
.
2018
;
15
(
1
):
72
80
.
40.
Azmi
H
,
Machado
A
,
Deogaonkar
M
,
Rezai
A
.
Intracranial air correlates with preoperative cerebral atrophy and stereotactic error during bilateral STN DBS surgery for Parkinson’s disease
.
Stereotact Funct Neurosurg
.
2011
;
89
(
4
):
246
52
.
41.
Brooks
A
,
Hoyt
AT
.
Single-stage deep brain stimulator placement for movement disorders: a case series
.
Brain Sci
.
2021
;
11
(
5
):
592
.
42.
Chen
T
,
Mirzadeh
Z
,
Chapple
K
,
Lambert
M
,
Ponce
FA
.
Complication rates, lengths of stay, and readmission rates in “awake” and “asleep” deep brain simulation
.
J Neurosurg
.
2017
;
127
(
2
):
360
9
.
43.
Patel
NK
,
Plaha
P
,
Gill
SS
.
Magnetic resonance imaging-directed method for functional neurosurgery using implantable guide tubes
.
Neurosurgery
.
2007
;
61
(
5 Suppl 2
):
358
65
; discussion 365-6.
44.
Holl
EM
,
Petersen
EA
,
Foltynie
T
,
Martinez-Torres
I
,
Limousin
P
,
Hariz
MI
, et al
.
Improving targeting in image-guided frame-based deep brain stimulation
.
Neurosurgery
.
2010
;
67
(
2 Suppl Operative
):
437
47
.
45.
Li
C
,
Fan
X
,
Hong
J
,
Roberts
DW
,
Aronson
JP
,
Paulsen
KD
.
Model-based image updating for brain shift in deep brain stimulation electrode placement surgery
.
IEEE Trans Biomed Eng
.
2020
;
67
(
12
):
3542
52
.
You do not currently have access to this content.