Introduction: Directional deep brain stimulation (DBS) leads have become widely used in the past decade. Understanding the asymmetric stimulation provided by directional leads requires precise knowledge of the exact orientation of the lead in respect to its anatomical target. Recently, the DiODe algorithm was developed to automatically determine the orientation angle of leads from the artifact on postoperative computed tomography (CT) images. However, manual DiODe results are user-dependent. This study analyzed the extent of lead rotation as well as the user agreement of DiODe calculations across the two most common DBS systems, namely, Boston Scientific’s Vercise and Abbott’s Infinity, and two independent medical institutions. Methods: Data from 104 patients who underwent an anterior-facing unilateral/bilateral directional DBS implantation at either Northwestern Memorial Hospital (NMH) or Albany Medical Center (AMC) were retrospectively analyzed. Actual orientations of the implanted leads were independently calculated by three individual users using the DiODe algorithm in Lead-DBS and patients’ postoperative CT images. The deviation from the intended orientation and user agreement were assessed. Results: All leads significantly deviated from the intended 0° orientation (p < 0.001), regardless of DBS lead design (p < 0.05) or institution (p < 0.05). However, the Boston Scientific leads showed an implantation bias toward the left at both institutions (p = 0.014 at NMH, p = 0.029 at AMC). A difference of 10° between at least two users occurred in 28% (NMH) and 39% (AMC) of all Boston Scientific and 76% (NMH) and 53% (AMC) of all Abbott leads. Conclusion: Our results show that there is a significant lead rotation from the intended surgical orientation across both DBS systems and both medical institutions; however, a bias toward a single direction was only seen in the Boston Scientific leads. Additionally, these results raise questions into the user error that occurs when manually refining the orientation angles calculated with DiODe.

1.
Vu
J
,
Bhusal
B
,
Nguyen
BT
,
Sanpitak
P
,
Nowac
E
,
Pilitsis
J
.
A comparative study of RF heating of deep brain stimulation devices in vertical vs. horizontal MRI systems
.
PLoS One
.
2022 Dec 9
17
12
e0278187
.
2.
Chow
CT
,
Kashyap
S
,
Loh
A
,
Naheed
A
,
Bennett
N
,
Golestanirad
L
.
Safety of magnetic resonance imaging in patients with deep brain stimulation
. In:
Magnetic resonance imaging in deep brain stimulation
Cham
Springer International Publishing
2022
. p.
55
72
.
3.
Golestanirad
L
,
Iacono
MI
,
Keil
B
,
Angelone
LM
,
Bonmassar
G
,
Fox
MD
.
Construction and modeling of a reconfigurable MRI coil for lowering SAR in patients with deep brain stimulation implants
.
Neuroimage
.
2017 Feb
147
577
88
.
4.
Bhusal
B
,
Nguyen
BT
,
Sanpitak
PP
,
Vu
J
,
Elahi
B
,
Rosenow
J
.
Effect of device configuration and patient’s body composition on the RF heating and nonsusceptibility artifact of deep brain stimulation implants during MRI at 1.5T and 3T
.
J Magn Reson Imaging
.
2021 Feb 28
53
2
599
610
.
5.
Golestanirad
L
,
Kirsch
J
,
Bonmassar
G
,
Downs
S
,
Elahi
B
,
Martin
A
.
RF-induced heating in tissue near bilateral DBS implants during MRI at 1.5 T and 3T: the role of surgical lead management
.
Neuroimage
.
2019 Jan
184
566
76
.
6.
Kazemivalipour
E
,
Keil
B
,
Vali
A
,
Rajan
S
,
Elahi
B
,
Atalar
E
.
Reconfigurable MRI technology for low-SAR imaging of deep brain stimulation at 3T: application in bilateral leads, fully-implanted systems, and surgically modified lead trajectories
.
Neuroimage
.
2019 Oct
199
18
29
.
7.
Loh
A
,
Gwun
D
,
Chow
CT
,
Boutet
A
,
Tasserie
J
,
Germann
J
.
Probing responses to deep brain stimulation with functional magnetic resonance imaging
.
Brain Stimul
.
2022 May
15
3
683
94
.
8.
Boutet
A
,
Madhavan
R
,
Elias
GJB
,
Joel
SE
,
Gramer
R
,
Ranjan
M
.
Predicting optimal deep brain stimulation parameters for Parkinson’s disease using functional MRI and machine learning
.
Nat Commun
.
2021 May 24
12
1
3043
.
9.
Waldthaler
J
,
Bopp
M
,
Kühn
N
,
Bacara
B
,
Keuler
M
,
Gjorgjevski
M
.
Imaging-based programming of subthalamic nucleus deep brain stimulation in Parkinson’s disease
.
Brain Stimul
.
2021 Sep
14
5
1109
17
.
10.
Bhusal
B
,
Stockmann
J
,
Guerin
B
,
Mareyam
A
,
Kirsch
J
,
Wald
LL
.
Safety and image quality at 7T MRI for deep brain stimulation systems: ex vivo study with lead-only and full-systems
.
PLoS One
.
2021 Sep 7
16
9
e0257077
.
11.
Duchin
Y
,
Shamir
RR
,
Patriat
R
,
Kim
J
,
Vitek
JL
,
Sapiro
G
.
Patient-specific anatomical model for deep brain stimulation based on 7 Tesla MRI
.
PLoS One
.
2018 Aug 22
13
8
e0201469
.
12.
Kim
J
,
Duchin
Y
,
Shamir
RR
,
Patriat
R
,
Vitek
J
,
Harel
N
.
Automatic localization of the subthalamic nucleus on patient-specific clinical MRI by incorporating 7 T MRI and machine learning: application in deep brain stimulation
.
Hum Brain Mapp
.
2019 Feb 1
40
2
679
98
.
13.
Picillo
M
,
Lozano
AM
,
Kou
N
,
Puppi Munhoz
R
,
Fasano
A
.
Programming deep brain stimulation for Parkinson’s disease: the toronto western hospital algorithms
.
Brain Stimul
.
2016 May
9
3
425
37
.
14.
Rebelo
P
,
Green
AL
,
Aziz
TZ
,
Kent
A
,
Schafer
D
,
Venkatesan
L
.
Thalamic directional deep brain stimulation for tremor: spend less, get more
.
Brain Stimul
.
2018 May
11
3
600
6
.
15.
Dembek
TA
,
Reker
P
,
Visser-Vandewalle
V
,
Wirths
J
,
Treuer
H
,
Klehr
M
.
Directional DBS increases side-effect thresholds — a prospective, double-blind trial
.
Mov Disord
.
2017 Oct 1
32
10
1380
8
.
16.
Butson
CR
,
McIntyre
CC
.
Current steering to control the volume of tissue activated during deep brain stimulation
.
Brain Stimul
.
2008
;
1
(
1
):
7
15
.
17.
Kramme
J
,
Dembek
TA
,
Treuer
H
,
Dafsari
HS
,
Barbe
MT
,
Wirths
J
.
Potentials and limitations of directional deep brain stimulation: a simulation approach
.
Stereotact Funct Neurosurg
.
2021
;
99
(
1
):
65
74
.
18.
Pollo
C
,
Kaelin-Lang
A
,
Oertel
MF
,
Stieglitz
L
,
Taub
E
,
Fuhr
P
.
Directional deep brain stimulation: an intraoperative double-blind pilot study
.
Brain
.
2014 Jul
137
Pt 7
2015
26
.
19.
Steigerwald
F
,
Müller
L
,
Johannes
S
,
Matthies
C
,
Volkmann
J
.
Directional deep brain stimulation of the subthalamic nucleus: a pilot study using a novel neurostimulation device
.
Mov Disord
.
2016 Aug 31
31
8
1240
3
.
20.
Kuncel
AM
,
Grill
WM
.
Selection of stimulus parameters for deep brain stimulation
.
Clin Neurophysiol
.
2004 Nov
115
11
2431
41
.
21.
Ondo
WG
,
Bronte-Stewart
H
DBS Study Group
.
The North American survey of placement and adjustment strategies for deep brain stimulation
.
Stereotact Funct Neurosurg
.
2005 Dec
83
4
142
7
.
22.
Temel
Y
,
Kessels
A
,
Tan
S
,
Topdag
A
,
Boon
P
,
Visser-Vandewalle
V
.
Behavioural changes after bilateral subthalamic stimulation in advanced Parkinson disease: a systematic review
.
Parkinsonism Relat Disord
.
2006 Jun
12
5
265
72
.
23.
Jiang
F
,
Elahi
B
,
Saxena
M
,
Telkes
I
,
DiMarzio
M
,
Pilitsis
JG
.
Patient-specific modeling of the volume of tissue activated (VTA) is associated with clinical outcome of DBS in patients with an obsessive-compulsive disorder
. In:
2021 43rd annual international conference of the IEEE engineering in medicine and biology society (EMBC)
IEEE
2021
. p.
5889
92
.
24.
Pavese
N
,
Tai
YF
,
Yousif
N
,
Nandi
D
,
Bain
PG
.
Traditional trial and error versus neuroanatomic 3-dimensional image software-assisted deep brain stimulation programming in patients with Parkinson disease
.
World Neurosurg
.
2020 Feb
134
e98
102
.
25.
Jiang
F
,
Nguyen
BT
,
Elahi
B
,
Pilitsis
J
,
Golestanirad
L
.
Effect of biophysical model complexity on predictions of volume of tissue activated (VTA) during deep brain stimulation
. In:
2020 42nd annual international conference of the IEEE engineering in medicine and biology society (EMBC)
IEEE
2020
. p.
3629
33
.
26.
Roediger
J
,
Dembek
TA
,
Wenzel
G
,
Butenko
K
,
Kühn
AA
,
Horn
A
.
StimFit — a data-driven algorithm for automated deep brain stimulation programming
.
Mov Disord
.
2022
;
37
(
3
):
574
84
.
27.
Lange
F
,
Steigerwald
F
,
Malzacher
T
,
Brandt
GA
,
Odorfer
TM
,
Roothans
J
.
Reduced programming time and strong symptom control even in chronic course through imaging-based DBS programming
.
Front Neurol
.
2021 Nov
12
785529
.
28.
Sitz
A
,
Hoevels
M
,
Hellerbach
A
,
Gierich
A
,
Luyken
K
,
Dembek
TA
.
Determining the orientation angle of directional leads for deep brain stimulation using computed tomography and digital x-ray imaging: a phantom study
.
Med Phys
.
2017 Sep 1
44
9
4463
73
.
29.
Hellerbach
A
,
Dembek
TA
,
Hoevels
M
,
Holz
JA
,
Gierich
A
,
Luyken
K
.
DiODe: directional orientation detection of segmented deep brain stimulation leads: a sequential algorithm based on CT imaging
.
Stereotact Funct Neurosurg
.
2018 Dec 1
96
5
335
41
.
30.
Dembek
TA
,
Hoevels
M
,
Hellerbach
A
,
Horn
A
,
Petry-Schmelzer
JN
,
Borggrefe
J
.
Directional DBS leads show large deviations from their intended implantation orientation
.
Parkinsonism Relat Disord
.
2019 Oct 1
67
117
21
.
31.
Lange
F
,
Steigerwald
F
,
Engel
D
,
Malzacher
T
,
Neun
T
,
Fricke
P
.
Longitudinal assessment of rotation angles after implantation of directional deep brain stimulation leads
.
Stereotact Funct Neurosurg
.
2021 Apr 1
99
2
150
8
.
32.
Reinacher
PC
,
Krüger
MT
,
Coenen
VA
,
Shah
M
,
Roelz
R
,
Jenkner
C
.
Determining the orientation of directional deep brain stimulation electrodes using 3D rotational fluoroscopy
.
AJNR Am J Neuroradiol
.
2017 Jun
38
6
1111
6
.
33.
Henry
KR
,
Miulli
MM
,
Elahi
B
,
Rosenow
J
,
Nolt
M
,
Golestanirad
L
.
Analysis of the intended and actual orientations of directional deep brain stimulation leads across deep brain stimulation systems
.
Annu Int Conf IEEE Eng Med Biol Soc
.
2022
;
2022
:
1725
8
.
34.
Dembek
TA
,
Hellerbach
A
,
Jergas
H
,
Eichner
M
,
Wirths
J
,
Dafsari
HS
.
DiODe v2: unambiguous and fully-automated detection of directional DBS lead orientation
.
Brain Sci
.
2021 Oct 31
11
11
1450
.
35.
Horn
A
,
Kühn
AA
.
Lead-DBS: a toolbox for deep brain stimulation electrode localizations and visualizations
.
Neuroimage
.
2015 Feb 5
107
127
35
.
36.
Horn
A
,
Li
N
,
Dembek
TA
,
Kappel
A
,
Boulay
C
,
Ewert
S
.
Lead-DBS v2: towards a comprehensive pipeline for deep brain stimulation imaging
.
Neuroimage
.
2019 Jan 1
184
293
316
.
37.
Lofredi
R
,
Auernig
CG
,
Ewert
S
,
Irmen
F
,
Steiner
LA
,
Scheller
U
.
Interrater reliability of deep brain stimulation electrode localizations
.
Neuroimage
.
2022 Nov
262
119552
.
38.
Rau
A
,
Urbach
H
,
Coenen
VA
,
Egger
K
,
Reinacher
PC
.
Deep brain stimulation electrodes may rotate after implantation — an animal study
.
Neurosurg Rev
.
2021 Aug 1
44
4
2349
53
.
You do not currently have access to this content.