Introduction: Essential tremor (ET) is one of the most prevalent movement disorders in adults and may be highly disabling for some. Magnetic resonance image-guided high-intensity focused ultrasound (MRIgFUS) has been shown to control tremor efficaciously and with acceptable risk. To date, paresthesia and ataxia are the most common adverse effects (AE). Nevertheless, the impact of MRIgFUS thalamotomy on balance is not well established. Methods: Thirty-two patients underwent MRIgFUS for ET and completed 6 months of follow-up. Tremor severity and functional disability were assessed using the Essential Tremor Rating Scale and the Quality of Life in Essential Tremor Questionnaire. The Berg Balance Scale (BBS) was applied to objectively measure balance status. Results: All treatments were successful. The sonication target was 1–2 mm above the depth of the intercommissural line. Procedures lasted less the 2 h, with an average of 8 sonications per patient. Twenty-four patients were included in the tremor analysis. The hand tremor score was improved by 76% after 6 months of follow-up and 87% of patients self-reported marked improvement (≥75%). Disability scores showed marked improvement (78%), leading to a significant improvement in quality of life. At the final follow-up, 48% of the patients reported no side effects. When present, AE were generally transient and were considered mild in 96% of affected patients. Paresthesia and subjective feeling of unsteadiness were the most common persistent complaints (23% and 20%, respectively). Regarding objective ataxia, BBS scores remained stable throughout follow-up for most patients. Only 2 patients suffered a mild worsening of balance although no patients experienced moderate or severe ataxia. Conclusions: Subjective feeling of unsteadiness is one of the most frequent AE after MRIgFUS, although objective ataxia is infrequent and mild. Selecting the most appropriate lesion location and procedural parameters should increase treatment benefits while reducing side effects.

1.
Bhatia KP, Bain P, Bajaj N, Elble RJ, Hallett M, Louis ED, et al. Consensus statement on the classification of tremors. From the task force on tremor of the international Parkinson and movement disorder society. Mov Disord. 2018;33(1):75–87.
2.
Louis ED, Ferreira JJ. How common is the most common adult movement disorder? update on the worldwide prevalence of essential tremor. Mov Disord. 2010;25(5):534–41.
3.
Tröster AI, Pahwa R, Fields JA, Tanner CM, Lyons KE. Quality of life in essential tremor Questionnaire (QUEST): development and initial validation. Parkinsonism Relat Disord. 2005;11(6):367–73.
4.
Louis ED, Machado DG. Tremor-related quality of life: a comparison of essential tremor vs. Parkinson’s disease patients. Parkinsonism Relat Disord. 2015;21(7):729–35.
5.
Zesiewicz TA, Elble RJ, Louis ED, Gronseth GS, Ondo WG, Dewey RB, et al. Evidence-based guideline update: treatment of essential tremor: report of the quality standards subcommittee of the American academy of neurology. Neurology. 2011;77(19):1752–5.
6.
Ferreira JJ, Mestre TA, Lyons KE, Benito-León J, Tan EK, Abbruzzese G, et al. MDS evidence-based review of treatments for essential tremor. Mov Disord. 2019;34(7):950–8.
7.
Dallapiazza RF, Lee DJ, De Vloo P, Fomenko A, Hamani C, Hodaie M, et al. Outcomes from stereotactic surgery for essential tremor. J Neurol Neurosurg Psychiatry. 2019;90(4):474–82.
8.
Elias WJ, Huss D, Voss T, Loomba J, Khaled M, Zadicario E, et al. A pilot study of focused ultrasound thalamotomy for essential tremor. N Engl J Med. 2013;369(7):640–8.
9.
Lipsman N, Schwartz ML, Huang Y, Lee L, Sankar T, Chapman M, et al. MR-guided focused ultrasound thalamotomy for essential tremor: a proof-of-concept study. Lancet Neurol. 2013; 12. p. 462–8.
10.
Elias WJ, Lipsman N, Ondo WG, Ghanouni P, Kim YG, Lee W, et al. A randomized trial of focused ultrasound thalamotomy for essential tremor. N Engl J Med. 2016;375(8):730–9.
11.
Chang WS, Jung HH, Kweon EJ, Zadicario E, Rachmilevitch I, Chang JW. Unilateral magnetic resonance guided focused ultrasound thalamotomy for essential tremor: practices and clinicoradiological outcomes. J Neurol Neurosurg Psychiatry. 2015;86(3):257–64.
12.
Gagliardo C, Cannella R, Quarrella C, D’Amelio M, Napoli A, Bartolotta TV, et al. Intraoperative imaging findings in transcranial MR imaging-guided focused ultrasound treatment at 1.5T may accurately detect typical lesional findings correlated with sonication parameters. Eur Radiol. 2020;30(9):5059–70.
13.
Gagliardo C, Marrale M, D’Angelo C, Cannella R, Collura G, Iacopino G, et al. Transcranial magnetic resonance imaging-guided focused ultrasound treatment at 1.5 T: A retrospective study on treatment- and patient-related parameters obtained from 52 procedures. Front Phys. 2020;7:1–9.
14.
Martin E, Jeanmonod D, Morel A, Zadicario E, Werner B. High-intensity focused ultrasound for noninvasive functional neurosurgery. Ann Neurol. 2009;66(6):858–61.
15.
Mohammed N, Patra D, Nanda A. A meta-analysis of outcomes and complications of magnetic resonance-guided focused ultrasound in the treatment of essential tremor. Neurosurg Focus. 2018;44:E4.
16.
Fishman PS, Elias WJ, Ghanouni P, Gwinn R, Lipsman N, Schwartz M, et al. Neurological adverse event profile of magnetic resonance imaging–guided focused ultrasound thalamotomy for essential tremor. Mov Disord. 2018;33(5):843–7.
17.
Iacopino DG, Gagliardo C, Giugno A, Giammalva GR, Napoli A, Maugeri R, et al. Preliminary experience with a transcranial magnetic resonance-guided focused ultrasound surgery system integrated with a 1.5-T MRI unit in a series of patients with essential tremor and Parkinson’s disease. Neurosurg Focus. 2018;44(2):E7.
18.
Chang WS, Jung HH, Zadicario E, Rachmilevitch I, Tlusty T, Vitek S, et al. Factors associated with successful magnetic resonance–guided focused ultrasound treatment: efficiency of acoustic energy delivery through the skull. J Neurosurg. 2016;124(2):411–6.
19.
Boutet A, Ranjan M, Zhong J, Germann J, Xu D, Schwartz ML, et al. Focused ultrasound thalamotomy location determines clinical benefits in patients with essential tremor. Brain. 2018;141(12):3405–14.
20.
Stacy MA, Elble RJ, Ondo WG, Wu SC, Hulihan J; TRS study group. Assessment of interrater and intrarater reliability of the fahn-tolosa-marin tremor rating scale in essential tremor. Mov Disord. 2007;22(6):833–8.
21.
Berg K, Wood-Dauphinee S, Williams JI, Gayton D. Measuring balance in the elderly: preliminary development of an instrument. Physiother Can. 1989;41(6):304–11.
22.
Downs S. The Berg balance scale. J physiother. 2015;61(6):46.
23.
Berg KO, Wood-Dauphinee SL, Williams JI, Maki B. Measuring balance in the elderly: validation of an instrument. Can J Public Heal. 1992;83(Suppl 2):S7–11.
24.
Donoghue D; Physiotherapy Research and Older People PROP group, Stokes EK, McAuliffe A, O’Neil S, Charthaigh EN. How much change is true change? The minimum detectable change of the Berg Balance Scale in elderly people. J Rehabil Med. 2009;41(5):343–6.
25.
Kim M, Jung NY, Park CK, Chang WS, Jung HH, Chang JW. Comparative evaluation of magnetic resonance-guided focused ultrasound surgery for essential tremor. Stereotact Funct Neurosurg. 2017;95(4):279–86.
26.
Krishna V, Sammartino F, Cosgrove R, Ghanouni P, Schwartz M, Gwinn R, et al. Predictors of outcomes after focused ultrasound thalamotomy. Neurosurgery. 2020;87(2):229–37.
27.
Meng Y, Solomon B, Boutet A, Llinas M, Scantlebury N, Huang Y, et al. Magnetic resonance–guided focused ultrasound thalamotomy for treatment of essential tremor: a 2-year outcome study. Mov Disord. 2018;33(10):1647–50.
28.
Halpern CH, Santini V, Lipsman N, Lozano AM, Schwartz ML, Shah BB, et al. Three-year follow-up of prospective trial of focused ultrasound thalamotomy for essential tremor. Neurology. 2019;93(24):E2284–93.
29.
Park YS, Jung NY, Na YC, Chang JW. Four-year follow-up results of magnetic resonance-guided focused ultrasound thalamotomy for essential tremor. Mov Disord. 2019;34(5):727–34.
30.
Kapadia AN, Elias GJB, Boutet A, Germann J, Pancholi A, Chu P, et al. Multimodal MRI for MRgFUS in essential tremor: post-treatment radiological markers of clinical outcome. J Neurol Neurosurg Psychiatry. 2020;91(9):921–7.
31.
Jolesz FA, Hynynen K. Magnetic resonance image-guided focused ultrasound surgery. Cancer J. 2002;8(Suppl 1):S100–12.
32.
Wintermark M, Druzgal J, Huss DS, Khaled MA, Monteith S, Raghavan P, et al. Imaging findings in mr imaging-guided focused ultrasound treatment for patients with essential tremor. AJNR Am J Neuroradiol. 2014;35(5):891–6.
33.
Hughes A, Huang Y, Schwartz ML, Hynynen K. The reduction in treatment efficiency at high acoustic powers during MR-guided transcranial focused ultrasound thalamotomy for Essential Tremor. Med Phys. 2018;45(7):2925–36.