Managing complex benign airway disease is a major challenge in interventional pulmonology. Airway stent placement can result in complications due to a variety of factors, including poor fit of the stent in the airway. We report the 1-year outcome of 2 patients with airway disease caused by granulomatosis with polyangiitis (Wegener’s) affecting the left main bronchus and secondary carina. These patients had not responded to systemic therapy or standard bronchoscopic techniques and had complications with commercially available airway stents. We describe a first-in-human, clinical experience to address these issues. Using computed tomography (CT) imaging and 3D printing technology, we generated and implanted patient-specific silicone airway stents to address airway disease. 3D patient-specific stent prescription was created using a CT scan of the patient’s chest and a proprietary software package originally developed for orthopedic surgical planning. Silicone stents were manufactured and implanted. Observation for > 1 year after implantation compared to the 6 months prior to patient-specific stent implant were compared for the number, clinically required stent changes, procedure time, and general clinical improvement per usual standard of care after airway stenting. Patients showed improved durability, a shorter procedure time, and improvement of patient-reported symptoms leading to a reduced need for stent changes and modifications. The use of 3D printing technology to make patient-specific silicone stents is feasible with early clinical proof of concept noting a durable improvement over 1 year of follow-up.

1.
Dumon JF: A dedicated tracheobronchial stent. Chest 1990; 97: 328–332.
2.
Breen DP, Dutau H: On-site customization of silicone stents: towards optimal palliation of complex airway conditions. Respiration 2009; 77: 447–453.
3.
Dutau H, Cavailles A, Sakr L, et al: A retrospective study of silicone stent placement for management of anastomotic airway complications in lung transplant recipients: short- and long-term outcomes. J Heart Lung Transplant 2010; 29: 658–664.
4.
Wood DE, Liu YH, Vallieres E, Karmy-Jones R, Mulligan MS: Airway stenting for malignant and benign tracheobronchial stenosis. Ann Thorac Surg 2003; 76: 167–172; discussion 173–174.
5.
Casal RF: Update in airway stents. Curr Opin Pulm Med 2010; 16: 321–328.
6.
U.S. Food and Drug Administration, Center for Devices and Radiological Health: FDA public health notification: complications from metallic tracheal stents in patients with benign airway disorders. August 2, 2005. www.jsre.org/info/0801_fda.pdf.
7.
Dutau H, Breen D, Bugalho A, et al: Current practice of airway stenting in the adult population in Europe: a survey of the European Association of Bronchology and Interventional Pulmonology (EABIP). Respiration 2018; 95: 44–54.
8.
Saad CP, Murthy S, Krizmanich G, Mehta AC: Self-expandable metallic airway stents and flexible bronchoscopy: long-term outcomes analysis. Chest 2003; 124: 1993–1999.
9.
Fortin M, MacEachern P, Hergott CA, Chee A, Dumoulin E, Tremblay A: Self-expandable metallic stents in nonmalignant large airway disease. Can Respir J 2015; 22: 235–236.
10.
Chung FT, Lin SM, Chen HC, et al: Factors leading to tracheobronchial self-expandable metallic stent fracture. J Thorac Cardiovasc Surg 2008; 136: 1328–1335.
11.
Trevisan F, Calignano F, Aversa A, et al: Additive manufacturing of titanium alloys in the biomedical field: processes, properties and applications. J Appl Biomater Funct Mater 2018; 16: 57–67.
12.
Morrison RJ, Hollister SJ, Niedner MF, et al: Mitigation of tracheobronchomalacia with 3D-printed personalized medical devices in pediatric patients. Sci Transl Med 2015; 7: 285ra64.
13.
van Eijnatten M, van Dijk R, Dobbe J, Streekstra G, Koivisto J, Wolff J: CT image segmentation methods for bone used in medical additive manufacturing. Med Eng Phys 2018; 51: 6–16.
14.
FDA: 3D printing of medical devices. 2018.
15.
FDA: Expanded access (sometimes called “compassionate use”). 2018.
16.
Delaere P, Vranckx J, Verleden G, De Leyn P, Van Raemdonck D, Leuven Tracheal Transplant Group: Tracheal allotransplantation after withdrawal of immunosuppressive therapy. N Engl J Med 2010; 362: 138–145.
17.
Cheng GZ, Folch E, Brik R, et al: Three-dimensional modeled T-tube design and insertion in a patient with tracheal dehiscence. Chest 2015; 148:e106–e108.
18.
Zopf DA, Hollister SJ, Nelson ME, Ohye RG, Green GE: Bioresorbable airway splint created with a three-dimensional printer. N Engl J Med 2013; 368: 2043–2045.
19.
Guibert N, Didier A, Moreno B, et al: Treatment of post-transplant complex airway Stenosis with a three-dimensional, computer-assisted customized airway stent. Am J Respir Crit Care Med 2017; 195:e31–e33.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.