Background: Decannulation failure is usually due to tracheal obstruction. Prior to decannulation, inspection by the invasive procedure of bronchoscopy that permits morphological evaluation of a tracheal stenosis is standard practice. A non-invasive method enabling the quantification of the airway obstruction that requires little cooperation is measurement of the airway resistance by the forced oscillation technique. Objectives: The aim of the present study was to define oscillatory impedance thresholds which predict successful decannulation. Methods: A total of 131 patients were investigated prospectively. Step 1: Following probatory decannulation, measurement of the oscillatory impedance. Step 2: Blinded to the results of the impedance measurement, bronchoscopy-assisted decannulation attempt. The criteria for renewed cannulation were high-grade laryngeal or tracheal obstruction, dyspnea or stridor, or a drop in SaO2 <90% under O2 insufflation. Statistics: Determination of the ratio tracheal tube remains/tracheal tube removed (TT+/TT–) for every measured value of the oscillatory resistance at 5 Hz (Ros 5 Hz). Determination of specificity and positive predictive value for determined threshold values with respect to TT–. Results: The data of 126 patients were evaluated. TT+ n = 26, TT– n = 100. Decannulation on the basis of bronchoscopy criteria: Specificity and positive predictive value found out for Ros 5 Hz <0.35 kPa/l/s (n = 44) were 1.00 and 1.00, respectively, and for Ros 5 Hz <0.47 kPa/l/s (n = 71) 0.88 and 0.96, respectively. Conclusions: Measurement of the oscillatory airway resistance represents a practicable method prior to decannulation. Below a value of Ros 5 Hz <0.35 kPa/l/s, bronchoscopy would appear not to be necessary.

1.
Simpson TP, Day CJ, Jewkes CF, Manara AR: The impact of percutaneous tracheostomy on intensive care unit practice and training. Anaesthesia 1999;54:186–189.
2.
Cox CE, Carson SS, Holmes GM, Howard A, Carey TS: Increase in tracheostomy for prolonged mechanical ventilation in North Carolina, 1993–2002. Crit Care Med 2004;32:2219–2226.
3.
Law JH, Barnhart K, Rowlett W, de la Rocha O, Lowenberg S: Increased frequency of obstructive airway abnormalities with long-term tracheostomy. Chest 1993;104:136–138.
4.
Rumbak MJ, Graves AE, Scott MP, Sporn GK, Walsh FW, Anderson WM, Goldman AL: Tracheostomy tube occlusion protocol predicts significant tracheal obstruction to air flow in patients requiring prolonged mechanical ventilation. Crit Care Med 1997;25:413–417.
5.
Norwood S, Vallina VL, Short K, Saigusa M, Fernandez LG, McLarty JW: Incidence of tracheal stenosis and other late complications after percutaneous tracheostomy. Ann Surg 2000;232:233–241.
6.
Rumbak MJ, Walsh FW, Anderson WM, Rolfe MW, Salomon DA: Significant tracheal obstruction causing failure to wean in patients requiring prolonged mechanical ventilation: a forgotten complication of long-term mechanical ventilation. Chest 1999;115:1092–1095.
7.
Sullivan KJ, Durand M, Chang HK: A forced perturbation method of assessing pulmonary mechanical function in intubated infants. Pediatr Res 1991;29:82–88.
8.
Desager KN, Buhr W, Willemen M, van Bever HP, de Backer W, Vermeire PA, Lándsér FJ: Measurement of total respiratory impedance in infants by the forced oscillation technique. J Appl Physiol 1991;71:770–776.
9.
Müller E, Vogel J: Measurement and model-interpretation of new parameters of lung mechanics. Z Erkr Atmungsorgane 1981;157:340–344.
10.
Dollner R, Verch M, Schweiger P, Deluigi C, Graf B, Wallner F: Laryngotracheoscopic findings in long-term follow-up after Griggs tracheostomy. Chest 2002;122:206–212.
11.
Koitschev A, Graumueller S, Zenner HP, Dommerich S, Simon C: Tracheal stenosis and obliteration above the tracheostoma after percutaneous dilational tracheostomy. Crit Care Med 2003;31:1574–1576.
12.
Sue RD, Susanto I: Long-term complications of artificial airways. Clin Chest Med 2003;24:457–471.
13.
Merritt RM, Bent JP, Smith RJ: Suprastomal granulation tissue and pediatric tracheotomy decannulation. Laryngoscope 1997;107:868–871.
14.
Brichet A, Verkindre C, Dupont J, Carlier ML, Darras J, Wurtz A, Ramon P, Marquette CH: Multidisciplinary approach to management of postintubation tracheal stenoses. Eur Respir J 1999;13:888–893.
15.
Van Heurn LW, Theunissen PH, Ramsay G, Brink PR: Pathologic changes of the trachea after percutaneous dilatational tracheotomy. Chest 1996;109:1466–1469.
16.
Walz MK, Schmidt U: Tracheal lesion caused by percutaneous dilatational tracheostomy – a clinico-pathological study. Intensive Care Med 1999;25:102–105.
17.
Benjamin B, Kertesz T: Obstructive suprastomal granulation tissue following percutaneous tracheostomy. Anaesth Intensive Care 1999;27:596–600.
18.
Briche T, Le Manach Y, Pats B: Complications of percutaneous tracheostomy. Chest 2001;119:1282–1283.
19.
Epstein SK: Late complications of tracheostomy. Respir Care 2005;50:542–549.
20.
Cao J, Que C, Wang G, He B: Effect of posture on airway resistance in obstructive sleep apnea-hypopnea syndrome by means of impulse oscillation. Respiration 2009;77:38–43.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.