Background: In patients who are weaned with a tracheostomy tube (TT), continuous positive airway pressure (CPAP) is frequently used. Dedicated CPAP systems or ventilators with bulky tubing are usually applied. However, CPAP can also be effective without a ventilator by the disposable Boussignac CPAP (BCPAP) system that is normally used with face masks. Objective: It was the aim of this audit to evaluate the feasibility of low-level BCPAP in patients who were weaned with a TT. Methods: All patients at our surgical intensive care unit who received a TT for weaning were considered for application of BCPAP. Once patients had received minimal pressure support from the mechanical ventilator, the BCPAP device was connected to the TT three times a day for 30 min with pressure set to 3–5 cm H2O, FiO2 at 0.4 and with humidification. BCPAP was then gradually extended to 24 h/day. Patient acceptance, complications and outcome were recorded. Results: 58 patients received a TT to facilitate weaning. They had a median stay of 52 days in the intensive care unit during which they had an endotracheal tube for 22 days and a TT for 28 days. 50 of these patients (86%) received BCPAP for a median of 16 days. The lightweight BCPAP system was well tolerated without tube obstructions or accidental decannulations and may have contributed to patient mobility. No patient remained on ventilatory support after hospital discharge. In-hospital and 1-year survival were 86 and 71%, respectively. Conclusions: BCPAP is a feasible and safe method for weaning tracheostomy patients.

1.
MacIntyre NR, Cook DJ, Ely EW Jr, Epstein SK, Fink JB, Heffner JE, Hess D, Hubmayer RD, Scheinhorn DJ, American College of Chest Physicians, American Association for Respiratory Care, American College of Critical Care Medicine: Evidence-based guidelines for weaning and discontinuing ventilatory support: a collective task force facilitated by the American College of Chest Physicians, the American Association for Respi-ratory Care, and the American College of Critical Care Medicine. Chest 2001;120:375S–395S.
2.
Durbin CG Jr: Indications for and timing of tracheostomy. Respir Care 2005;50:483–487.
3.
Rumbak MJ, Newton M, Truncale T, Schwartz SW, Adams JW, Hazard PB: A prospective, randomized, study comparing early percutaneous dilational tracheotomy to prolonged translaryngeal intubation (delayed tracheotomy) in critically ill medical patients. Crit Care Med 2004;32:1689–1694; erratum p 2566.
4.
Pierson DJ: Tracheostomy from A to Z: historical context and current challenges. Respir Care 2005;50:473–475.
5.
Heffner JE: The role of tracheotomy in weaning. Chest 2001;120:477S–481S.
6.
Shneerson JM: Are there new solutions to old problems with weaning? Br J Anaesth 1997;78:238–240.
7.
Meade M, Guyatt G, Sinuff T, Griffith L, Hand L, Toprani G, Cook DJ: Trials com-paring alternative weaning modes and discontinuation assessments. Chest 2001;120:425S–437S.
8.
Polderman KH, Spijkstra JJ, de Bree R, Christiaans HM, Gelissen HP, Wester JP, Girbes AR: Percutaneous dilatational tracheostomy in the ICU: optimal organization, low complication rates, and description of a new complication. Chest 2003;123:1595–1602.
9.
Forbes AR: Humidification and mucus flow in the intubated trachea. Br J Anaesth 1973;45:874–878.
10.
Dieperink W, Delwig H, Nijsten MWN: Application of Boussignac CPAP system on tracheostomy tubes during weaning. Intensive Care Med 2005;31(suppl 1):S193.
11.
Dieperink W, Goorhuis JF, de Weerd W, Hazenberg A, Zijlstra JG, Nijsten MWN: Walking with continuous positive airway pressure. Eur Respir J 2006;27:853–855.
12.
Maitre B, Jaber S, Maggiore SM, Bergot E, Richard JC, Bakthiari H, Housset B, Boussignac G, Brochard L: Continuous positive airway pressure during fiberoptic bronchoscopy in hypoxemic patients. A randomized double-blind study using a new device. Am J Respir Crit Care Med 2000;162:1063–1067.
13.
Moritz F, Benichou J, Vanheste M, Richard JC, Line S, Hellot MF, Bonmarchand G, Muller JM: Boussignac continuous positive airway pressure device in the emergency care of acute cardiogenic pulmonary oedema: a randomized pilot study. Eur J Emerg Med 2003;10:204–208.
14.
Templier F, Dolveck F, Baer M, Chauvin M, Fletcher D: ‘Boussignac’ continuous positive airway pressure system: practical use in a prehospital medical care unit. Eur J Emerg Med 2003;10:87–93.
15.
Leman P, Greene S, Whelan K, Legassick T: Simple lightweight disposable continuous positive airways pressure mask to effectively treat acute pulmonary oedema: randomized controlled trial. Emerg Med Australas 2005;17:224–230.
16.
Liener K, Durr L, Leiacker R, Rozsasi A, Keck T: Measurement of tracheal humidity and temperature. Respiration 2006;73:324–328.
17.
Lavrentieva A, Setzis D, Giannakou M, Tsotsolis V, Ourailogloy V, Theodosiadis P, Skourtis X, Sofanos E: Use of Boussignac-Vygon CPAP system in ICU patients with tracheostomy. Resuscitation 2000;48:1 P28.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.