Background: After tracheostomy, patients often present with chest complaints. Measurement of objective parameters of the tracheal climate is important to evaluate ‘artificial noses’ or humidifying devices. Objectives: The purpose of this study was to present an experimental setup for measurement of tracheal temperature and humidity for possible use in clinical studies in tracheotomized patients. Methods: The study design was a prospective study. Patients with tracheal stoma were chosen as study participants. Tracheal temperature and humidity during the respiratory cycle were measured using a miniaturized thermocouple and a humidity sensor connected to a suction system. Results: Accurate measurement of tracheal temperature and humidity was feasible in patients with tracheal stoma. Tracheal humidity and temperature values measured in this study were similar to values reported earlier by other working groups. Conclusions: The experimental setup presented may reliably be used in the evaluation of ‘artificial noses’ or other passive humidifiers in tracheotomized patients.

1.
McRae RDR, Jones AS, Young P, Hamilton J: Resistance, humidity and temperature of the tracheal airway. Clin Otolaryngol 1995;20:355–356.
2.
Rathgeber J, Betker T, Zuchner K: Measurement of water vapour pressure in the airways of mechanically ventilated patient using different types of humidifiers. Anasthesiol Intensivmed Notfallmed Schmerzther 2001;36:560–565.
3.
Miwa K, Mitsuoka M, Takamori S, Hayashi A, Shirouzu K: Continuous monitoring of oxygen consumption in patients undergoing weaning from mechanical ventilation. Respiration 2003;70:623–630.
4.
Wiest GH, Harsch IA, Fuchs FS, Kitzbichler S, Bogner K, Brueckl WM, Hahn EG, Ficker JH: Initiation of CPAP therapy for OSA: does prophylactic humidification during CPAP pressure titration improve initial patient acceptance and comfort? Respiration 2002;69:406–412.
5.
Chatburn RL, Primiano FP: A rational basis for humidity therapy. Respir Care 1987;32:249–254.
6.
Keck T, Leiacker R, Heinrich A, Kühnemann S, Rettinger G: Humidity and temperature profile in the nasal cavity. Rhinology 2000;38:167–171.
7.
Lindemann J, Leiacker R, Rettinger G, Keck T: The relationship between water vapour saturation of inhaled air and nasal patency. Eur Respir J 2003;21:313–316.
8.
Rozsasi A, Leiacker R, Keck T: Nasal conditioning in perennial allergic rhinitis after nasal allergen challenge. Clin Exp Allergy 2004;34:1099–1104.
9.
Rouadi P, Baroody FM, Abbott D, Naureckas E, Solway J, Nacleiro RM: A technique to measure the ability of the human nose to warm and humidify air. J Appl Physiol 1999;87:400–406.
10.
Larsson A, Gustafsson A, Svanborg L: A new device for 100 per cent humidification of inspired air. Crit Care 2000;4:54–60.
11.
Thomachot L, Viviand X, Lagier P, Dejode JM, Albanese J, Martin C: Measurement of tracheal temperature is not a reliable index of total respiratory heat loss in mechanically ventilated patients. Crit Care 2001;5:24–30.
12.
Corfield DR, Webber SE, Widdicombe JG: Distribution of blood flow in the perfused tracheae of sheep: a search for arteriovenous anastomoses. J Appl Physiol 1993;74:1856–1861.
13.
Solway J: Airway heat and water fluxes and the tracheobronchial circulation. Eur Respir J Suppl 1990;12:608s–617s.
14.
Williams R, Rankin N, Smith T, Galler D, Seakins P: Relationship between the humidity and temperature of inspired gas and the function of the airway mucosa. Crit Care Med 1996;24:1920–1929.
15.
Irlbeck D: Normal mechanisms of heat and moisture exchange in the respiratory tract. Respir Care Clin N Am 1998;4:189–198.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.