Objective: We retrospectively analyzed the surgical outcome and safety of the Montgomery T-tube for laryngotracheal stenosis. Methods: The patients with laryngotracheal stenosis who had undergone T-tube placement between 1996 and 2010 were reviewed. The severity of the stenosis was evaluated using the Cotton-Myer staging method. The primary endpoint was the rate of successful extubation and the secondary endpoint was safety. Results: 546 patients were eligible. T-tubes were successfully extubated in 342 patients 6-24 months following intubation. The initial extubation success rate was 62.3%. Laryngotracheal restenosis following extubation occurred in 192 patients, necessitating T-tube placement for a second time. The success rate for the second attempt was 58.9%. The overall success rate was 83.3%. Hemoptysis was reported in 8 patients, postoperative infection in 6 patients, wound dehiscence in 3 patients, laryngeal obstruction in 13 patients, aspiration in 12 patients, and postoperative tracheoesophageal fistula in 2 patients. Conclusion: This large clinical series demonstrated the safety and effectiveness of the T-tube for grade 1 and 2 stenosis with stenosed segments of <6 cm. For those being >6 cm, tracheal end-to-end anastomosis is not appropriate and long-term placement of a T-tube is recommended. Our findings provide useful guidance for preoperatively selecting patients with laryngotracheal stenosis of various causes and differing severity.

1.
Montgomery WW: Reconstruction of the cervical trachea. Ann Otol Rhinol Laryngol 1964;73:5-15.
2.
Pereszlenyi A, Igaz M, Majer I, Harustiak S: Role of endotracheal stenting in tracheal reconstruction surgery - retrospective analysis. Eur J Cardiothorac Surg 2004;25:1059-1064.
3.
Wahidi MM, Ernst A: The Montgomery T-tube tracheal stent. Clin Chest Med 2003;24:437-443.
4.
Puma F, Ragusa M, Avenia N, Urbani M, Droghetti A, Daddi N, Daddi G: The role of silicone stents in the treatment of cicatricial tracheal stenoses. J Thorac Cardiovasc Surg 2000;120:1064-1069.
5.
Liu HC, Lee KS, Huang CJ, Cheng CR, Hsu WH, Huang MH: Silicone T-tube for complex laryngotracheal problems. Eur J Cardiothorac Surg 2002;21:326-330.
6.
Phillips PS, Kubba H, Hartley BE, Albert DM: The use of the Montgomery T-tube in difficult paediatric airways. Int J Pediatr Otorhinolaryngol 2006;70:39-44.
7.
Martinez-Ballarin JI, Diaz-Jimenez JP, Castro MJ, Moya JA: Silicone stents in the management of benign tracheobronchial stenoses, tolerance and early results in 63 patients. Chest 1996;109:626-629.
8.
Preciado D, Zalzal G: Laryngeal and tracheal stents in children. Curr Opin Otolaryngol Head Neck Surg 2008;16:83-85.
9.
Cotton RT: Pediatric laryngotracheal stenosis. J Pediatr Surg 1984;19:699-704.
10.
Wang CY, Qin Y: Surgical management of laryngotracheal stenosis: a retrospective study of 53 cases. Chin J Otorhinolaryngol Head Neck Surg 2008;43:919-923.
11.
Liu LF, Wu WM, Wang JL, Feng B, Zhao H, Huang DL: Analysis of traumatic laryngotracheal stenosis in 63 cases. Chin J Otorhinolaryngol Head Neck Surg 2009;5:389-394.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.