Background: High-frequency B scan ultrasonography is a proven method for the assessment of anterior segment diseases. Only few studies have used sonography to examine the lacrimal drainage system. We examined the proximal lacrimal drainage system by high-resolution 20-MHz ultrasound to verify the possibility to identify intracanalicular lacrimal plugs. Methods: Eight patients who had received 12 lacrimal plug implants were examined by high-resolution ultrasound. A 20-MHz sector scanner was used for detection and localization of 2 types of intracanalicular plugs (Herrick® lacrimal silicone plug, Smart™ acrylic polymer plug) and 1 punctum plug. Ultrasound examinations were performed 1–24 months after plug placement. Cross-sections of the lacrimal canaliculi were obtained. Results: The various intracanalicular implants were successfully viewed using the 20-MHz ultrasound sector scanner. Intracanalicular plugs were located at the appropriate position as intended. The silicone plugs could be seen as areas of higher reflectivity. In contrast, acrylic polymer plugs were seen as low-reflective inner structures. In a longitudinal echogram, the interface between the acrylic polymer plug and the lacrimal canaliculus produced a strong acoustic impedance. In patients with an intracanalicular acrylic polymer plug, the caliber of the plug could be ascertained and the diameter measured. Conclusion: High-resolution ultrasound with a 20-MHz sector scanner is helpful in detecting intracanalicular plugs and is a valuable tool to assess the migration of lacrimal plugs through lacrimal canaliculi. A 20-MHz sector scanner can be used to identify and locate lacrimal plugs in the proximal drainage system even if biomicroscopic signs or clinical data are absent.

1.
Virtanen T, Huotari K, Harkonen M, Tervo T: Lacrimal plugs as a therapy for contact lens intolerance. Eye 1996;10:727–731.
2.
Affeldt J, Byron H, Dubow B, Hunter K, McCall J, White C, Williams P, Yassin J: Complications of lacrimal plug implantation. Ophthalmology 2003;110:4–5, author reply 5–6.
3.
Frankel J: Complications of lacrimal plug implantation. Ophthalmology 2003;110:3–4.
4.
Hsu HC: Ampullary pyogenic granuloma as a complication of lacrimal plug migration. Chang Gung Med J 2002;25:415–418.
5.
Jones CE, Anklesaria M, Gordon AD, Prouty RE, Rashid R, Singla RK, Schachet JL: Retrospective safety study of the Herrick lacrimal plug: A device used to occlude the lacrimal canaliculus. CLAO J 2002;28:206–210.
6.
Hamano T, Ohashi Y, Cho Y, Shimomura Y, Manabe R: A new punctum plug. Am J Ophthalmol 1985;100:619–620.
7.
Takemura M, Yokoi, N, Nakamura Y, Komuro A, Sugita J, Kinoshita S: Canaliculitis caused by Actinomyces in a case of dry eye with punctal plug occlusion. Jpn J Ophthalmol 2003;47:115.
8.
Rumelt S, Remulla H, Rubin PA: Silicone punctal plug migration resulting in dacryocystitis and canaliculitis. Cornea 1997;16:377–379.
9.
Knapp ME, Frueh BR, Nelson CC, Musch DC: A comparison of two methods of punctal occlusion. Am J Ophthalmol 1989;108:315–318.
10.
Fayet B, Bernard JA, Ammar J, Taylor Y, Bati E, Hurbli T, Mer C, Renard G, Pouliquen Y: Complications of punctum plug in the symptomatic treatment of dry eye. J Fr Ophtalmol 1990;13:135–142.
11.
White WL, Bartley GB, Hawes MJ, Linberg JV, Leventer DB: Iatrogenic complications related to the use of Herrick lacrimal plugs. Ophthalmology 2001;108:1835–1837.
12.
Lee J, Flanagan JC: Complications associated with silicone intracanalicular plugs. Ophthal Plast Reconstr Surg 2001;17:465–469.
13.
Tost F, Bruder R, Clemens S: Clinical diagnosis of chronic canaliculitis by 20-MHz ultrasound. Ophthalmologica 2000;214:433–436.
14.
Tost F, Bruder R, Clemens S: 20-MHz-Ultraschallechografie der Tränenwege. Ophthalmologe 2002;99:25–28.
15.
Roters S, Lüke C, Jonescu-Cuypers CP, Engels BF, Jacobi PC, Konen W, Krieglstein GK: Ultrasound biomicroscopy and its value in predicting the long term outcome of viscocanalostomy. Br J Ophthalmol 2002;86:997–1001.
16.
Wada S, Kohno T, Yanagihara N, Hirabayashi M, Tabuchi H, Shiraki K, Miki T: Ultrasound biomicroscopic study of ciliary body changes in the post-treatment phase of Vogt-Koyanagi-Harada disease. Br J Ophthalmol 2002;86:1374–1379.
17.
Hurwitz JJ, Pavlin CJ: Proximal canalicular imaging utilizing ultrasound biomicroscopy. Orbit 1998;17:31–36.
18.
Tost F, Bruder R: 20-MHz-Sonografie bei chronischer Kanalikulitis. Klin Monatsbl Augenheilkd 2000;216:240–242.
19.
Masket S: Smarter than your average plug. Cataract Refract Surgery Today 2001;10:1.
20.
Levenson JE, Hofbaver J: Problems with punctal plugs. Arch Ophthalmol 1989;107:493–495.
21.
Balaram M, Schaumberg DA, Dana MR: Efficacy and tolerability outcomes after punctal occlusion with silicone plugs in dry eye syndrome. Am J Ophthalmol 2001;131:30–36.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.