Introduction: Trans-scleral biopsy of uveal melanoma (UM) poses an inherent risk of tumor and possibly retinal perforation. We describe a novel technique for trans-scleral biopsy of UM and evaluate its safety and efficacy in an initial cohort of patients. Methods: A retrospective, consecutive observational case series was conducted from October 14, 2019, to April 15, 2020, at Kaiser Permanente, San Francisco, CA among patients with UM of the ciliary body or anterior choroid undergoing trans-scleral fine-needle aspiration biopsy using a novel guarded needle technique. Results: A total of 6 patients were included in the study, with a mean age of 64.3 (range 35–77) years (5 women 83%). Mean (±SD) tumor thickness and maximal basal diameter were 6.4 (±2.66) and 11.9 (±2.13) mm, respectively. Five out of 6 patients achieved a successful biopsy with reliable gene expression profiling (GEP) results. The only failure to obtain specimen occurred in the first attempted patient and, after a minor technique modification, all subsequent biopsies were successful. No intraoperative or short-term postoperative complications were observed in any patient. Conclusion: This novel trans-scleral biopsy technique appears to be safe and effective when obtaining UM tissue for GEP. This method may provide a more controlled biopsy depth thereby minimizing the risk of tumor perforation and its associated complications while still obtaining adequate biopsy yield.

1.
Seider
MI
,
Berry
DE
,
Berry
DE
,
Schefler
AC
,
Materin
M
,
Stinnett
S
,
Multi-center analysis of intraocular biopsy technique and outcomes for uveal melanoma: Ocular Oncology Study Consortium report 4
.
Graefes Arch Clin Exp Ophthalmol
.
2020 Feb
;
258
(
2
):
427
35
. .
2.
Sellam
A
,
Desjardins
L
,
Barnhill
R
,
Plancher
C
,
Asselain
B
,
Savignoni
A
,
Fine needle aspiration biopsy in uveal melanoma: technique, complications, and outcomes
.
Am J Ophthalmol
.
2016 Feb
;
162
:
28
e1
. .
3.
Mashayekhi
A
,
Lim
RP
,
Shields
CL
,
Eagle
RC
,
Shields
JA
.
Extraocular extension of ciliochoroidal melanoma after transscleral fine-needle aspiration biopsy
.
Retin Cases Brief Rep
.
2016
;
10
(
3
):
289
92
. .
4.
Singh
AD
,
Medina
CA
,
Singh
N
,
Aronow
ME
,
Biscotti
CV
,
Triozzi
PL
.
Fine-needle aspiration biopsy of uveal melanoma: outcomes and complications
.
Br J Ophthalmol
.
2016 Apr
;
100
(
4
):
456
62
. .
5.
Cohen
VM
,
Dinakaran
S
,
Parsons
MA
,
Rennie
IG
.
Transvitreal fine needle aspiration biopsy: the influence of intraocular lesion size on diagnostic biopsy result
.
Eye
.
2001 Mar
;
15
(
Pt 2
):
143
7
. .
6.
Faulkner-Jones
BE
,
Foster
WJ
,
Harbour
JW
,
Smith
ME
,
Dávila
RM
.
Fine needle aspiration biopsy with adjunct immunohistochemistry in intraocular tumor management
.
Acta Cytol
.
2005
;
49
(
3
):
297
308
. .
7.
McCannel
TA
,
Chang
MY
,
Burgess
BL
.
Multi-year follow-up of fine-needle aspiration biopsy in choroidal melanoma
.
Ophthalmology
.
2012 Mar
;
119
(
3
):
606
10
. .
8.
Transcleral Drainage Cannula [Hanscom] | BVI [Internet]. [cited 2020 Apr 26]. Available from: https://www.bvimedical.com/ophthalmic-products/transcleral-drainage-cannula-hanscom/
.
9.
Plasseraud
KM
,
Cook
RW
,
Tsai
T
,
Shildkrot
Y
,
Middlebrook
B
,
Maetzold
D
,
Clinical performance and management owith the DecisionDx-UM Gene Expression Profile Test in a Prospective Multicenter Study
.
J Oncol
.
2016
;
2016
:
5325762
. .
10.
Valsecchi
ME
,
Orloff
M
,
Sato
R
,
Chervoneva
I
,
Shields
CL
,
Shields
JA
,
Adjuvant sunitinib in high-risk patients with uveal melanoma: comparison with institutional controls
.
Ophthalmology
.
2018 Feb
;
125
(
2
):
210
7
. .
11.
Shields
CL
,
Ganguly
A
,
Materin
MA
,
Teixeira
L
,
Mashayekhi
A
,
Swanson
LA
,
Chromosome 3 analysis of uveal melanoma using fine-needle aspiration biopsy at the time of plaque radiotherapy in 140 consecutive cases
.
Trans Am Ophthalmol Soc
.
2007
;
105
:
43
3
; discussion 52–53
.
12.
Kitchens
JW
.
Modified external needle drainage of subretinal fluid in the management of rhegmatogenous retinal detachment using a “guarded needle” approach
.
Arch Ophthalmol
.
2011 Jul
;
129
(
7
):
949
51
. .
13.
Hanscom
T
.
External needle drainage device
.
Arch Ophthalmol
.
2012 Jan
;
130
(
1
):
126
. .
14.
Chang
MY
,
McCannel
TA
.
Comparison of uveal melanoma cytopathologic sample retrieval in trans-scleral versus vitrectomy-assisted transvitreal fine needle aspiration biopsy
.
Br J Ophthalmol
.
2014 Dec
;
98
(
12
):
1654
8
. .
15.
Kim
RS
,
Chevez-Barrios
P
,
Divatia
M
,
Bretana
ME
,
Teh
B
,
Schefler
AC
.
Yield, techniques, and complications of transvitreal and transscleral biopsies in small uveal melanoma
.
JAMA Ophthalmol
.
2018 1
;
136
(
5
):
482
8
. .
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.