Objective and methods: As the result of vigorous bubbling, infants receiving continuous positive airway pressure (CPAP) by an underwater seal (bubble CPAP) were observed to have vibrations of their chests at frequencies similar to high-frequency ventilation (HFV). We performed a randomized crossover study in 10 premature infants ready for extubation to test whether bubble CPAP contributes to gas exchange compared to conventional ventilator-derived CPAP. Measurements of tidal volume and minute volume were made using the Bear Cub neonatal volume monitor, and gas exchange was measured using an oxygen saturation monitor and a transcutaneous carbon dioxide (tcpCO2) monitor. Results: There was a 39% reduction in minute volume (p < 0.001) and a 7% reduction in respiratory rate (p = 0.004) with no change in tcpCO2 or O2 saturation for infants supported with bubble versus ventilator-derived CPAP. Conclusions: The lack of difference in blood gas parameters associated with a decrease in the infant’s minute volume and respiratory rate with bubble CPAP compared with ventilator-derived CPAP suggests that the chest vibrations produced with bubble CPAP may have contributed to gas exchange. Bubble CPAP may offer an effective and inexpensive option for providing respiratory support to premature infants.

This content is only available via PDF.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.