Introduction: Moderate and late preterm (MLPT) infants represent a substantial percentage of all preterm infants and frequently need support in the delivery room. Deferred cord clamping (DCC) improves SpO2 and heart rate (HR) stabilization in term infants. However, data on MLPT infants are limited. Methods: We performed a prospective observational study collecting SpO2 and HR by pulse oximetry in healthy MLPT infants with DDC to construct percentile graphs for the first 10 min after birth. Results: A total of 96 MLPT infants were monitored for preductal SpO2 and HR, and percentiles were calculated. SpO2 mean was significantly lower for MLPT than for term infants during the first 6 min after birth, and 15% did not achieve SpO2 ≥85% in the first 5 min after birth. HR was significantly lower in MLPT infants in the first 4 min after birth; however, HR consistently remained above bradycardic values (>100 bpm). NICU admission and postnatal complications were not different between MLPT achieving SpO2 ≥85% or not. Conclusion: MLPT infants with DCC achieved stable SpO2 and HR significantly later, 6 min and 4 min, respectively, than term infants. In addition, 15% of MLPT infants did not achieve SpO2 ≥85% at 5 min after birth. However, admission to the NICU and clinical evolution did not differ from newborns with SpO2 ≥85% at 5 min. Larger studies including long-term follow-up are needed to assess if lower SpO2 in the first 5 min has clinical consequences in non-resuscitated MLPT.

1.
Vento
M
,
Saugstad
OD
.
Targeting oxygen in term and preterm infants starting at birth
.
Clin Perinatol
.
2019
;
46
(
3
):
459
73
.
2.
Dawson
JA
,
Kamlin
COF
,
Vento
M
,
Wong
C
,
Cole
TJ
,
Donath
SM
, et al
.
Defining the reference range for oxygen saturation for infants after birth
.
Pediatrics
.
2010
;
125
(
6
):
e1340
7
.
3.
Dawson
JA
,
Kamlin
COF
,
Wong
C
,
Te Pas
AB
,
Vento
M
,
Cole
TJ
, et al
.
Changes in heart rate in the first minutes after birth
.
Arch Dis Child Fetal Neonatal Ed
.
2010
;
95
(
3
):
F177
81
.
4.
Padilla-Sánchez
C
,
Baixauli-Alacreu
S
,
Cañada-Martínez
A
,
Solaz-García
A
,
Alemany-Anchel
MJ
,
Vento
M
.
Delayed vs immediate cord clamping changes oxygen saturation and heart rate patterns in the first minutes after birth
.
J Pediatr
.
2020
;
227
:
149
56.e1
.
5.
Boyle
EM
.
The late and moderate preterm baby
.
Semin Fetal Neonatal Med
.
2012
;
17
(
3
):
119
.
6.
Shapiro-Mendoza
CK
,
Lackritz
EM
.
Epidemiology of late and moderate preterm birth
.
Semin Fetal Neonatal Med
.
2012
;
17
(
3
):
120
5
.
7.
García-Reymundo
M
,
Demestre
X
,
Calvo
MJ
,
Ginovart
G
,
Jiménez
A
,
Hurtado
JA
.
Grupo SEN34-36. Late preterm infants in Spain: experience of the 34-36 neonatal group
.
Pediatr
.
2018
;
88
(
5
):
246
52
.
8.
Engle
WA
,
Tomashek
KM
,
Wallman
C
;
Committee on Fetus and Newborn, American Academy of Pediatrics
.
“Late-preterm” infants: a population at risk
.
Pediatrics
.
2007
;
120
(
6
):
1390
401
.
9.
Boyle
EM
,
Johnson
S
,
Manktelow
B
,
Seaton
SE
,
Draper
ES
,
Smith
LK
, et al
.
Neonatal outcomes and delivery of care for infants born late preterm or moderately preterm: a prospective population-based study
.
Arch Dis Child Fetal Neonatal Ed
.
2015
;
100
(
6
):
F479
85
.
10.
Aziz
K
,
Lee
HC
,
Escobedo
MB
,
Hoover
AV
,
Kamath-Rayne
BD
,
Kapadia
VS
, et al
.
Part 5: neonatal resuscitation 2020 American Heart Association Guidelines for cardiopulmonary resuscitation and emergency cardiovascular care
.
Pediatrics
.
2021
;
147
(
Suppl 1
):
e2020038505E
.
11.
Dekker
J
,
Hooper
SB
,
Martherus
T
,
Cramer
SJE
,
van Geloven
N
,
Te Pas
AB
.
Repetitive versus standard tactile stimulation of preterm infants at birth–a randomized controlled trial
.
Resuscitation
.
2018
;
127
:
37
43
.
13.
Workie
FA
,
Rais-Bahrami
K
,
Short
BL
.
Clinical use of new-generation pulse oximeters in the neonatal intensive care unit
.
Am J Perinatol
.
2005
;
22
(
7
):
357
60
.
14.
O’Donnell
CP
,
Kamlin
CO
,
Davis
PG
,
Morley
CJ
.
Feasibility of and delay in obtaining pulse oximetry during neonatal resuscitation
.
J Pediatr
.
2005
;
147
(
5
):
698
9
.
15.
Massimo Europe Limited
. Product data sheet rad-97tm pulse CO-oximeter® (Ref.9500) Madrid: Spanish Division;
2019
.
16.
Alderliesten
T
,
Lemmers
PM
,
Baerts
W
,
Groenendaal
F
,
van Bel
F
.
Perfusion index in preterm infants during the first 3 days of life: reference values and relation with clinical variables
.
Neonatology
.
2015
;
107
(
4
):
258
65
.
17.
Kroese
JK
,
van Vonderen
JJ
,
Narayen
IC
,
Walther
FJ
,
Hooper
S
,
Te Pas
AB
.
The perfusion indexo f healthy term infants during transition at birth
.
Eur J Pediatr
.
2016
;
175
(
4
):
475
9
.
18.
Harrell
FE
Jr
.
R package version. Rms: regression modeling strategies
. In:
R package version 5.1-4
.
Vienna, Austria
:
R Foundation for Statistical Computing
;
2019
.
19.
Cole
TJ
,
Green
PJ
.
Smoothing reference centile curves: the lms method and penalized likelihood
.
Stat Med
.
1992
;
11
(
10
):
1305
19
.
20.
Chandra
P
,
Sundaram
V
,
Kumar
P
.
Oxygen saturation centiles in healthy preterm neonates in the first 10 min of life: a prospective observational study
.
Eur J Pediatr
.
2023
;
182
(
4
):
1637
45
.
21.
Hooper
SB
,
Te Pas
AB
,
Lang
J
,
van Vonderen
JJ
,
Roehr
CC
,
Kluckow
M
, et al
.
Cardiovascular transition at birth: a physiological sequence
.
Pediatr Res
.
2015
;
77
(
5
):
608
14
.
22.
Oei
JL
,
Finer
NN
,
Saugstad
OD
,
Wright
IM
,
Rabi
Y
,
Tarnow-Mordi
W
, et al
.
Outcomes of oxygen saturation targeting during delivery room stabilisation of preterm infants
.
Arch Dis Child Fetal Neonatal Ed
.
2018
;
103
(
5
):
F446
54
.
23.
Sotiropoulos
JX
,
Oei
JL
,
Schmölzer
GM
,
Libesman
S
,
Hunter
KE
,
Williams
JG
, et al
.
Initial oxygen concentration for the resuscitation of infants born at less than 32 weeks’ gestation. A systematic review and individual participant data network meta-analysis
.
JAMA Pediatr
.
2024
;
178
(
8
):
774
83
.
24.
Kapadia
V
,
Oei
JL
,
Finer
N
,
Rich
W
,
Rabi
Y
,
Wright
IM
, et al
.
Outcomes of delivery room resuscitation of bradycardic preterm infants: a retrospective cohort study of randomised trials of high vs low initial oxygen concentration and an individual patient data analysis
.
Resuscitation
.
2021
;
167
:
209
17
.
25.
Kapadia
VS
,
Kawakami
MD
,
Strand
ML
,
Hurst
CP
,
Spencer
A
,
Schmölzer
GM
, et al
.
Fast and accurate newborn heart rate monitoring at birth
.
A Syst Rev
.
2024
;
19
:
100688
.
You do not currently have access to this content.