Background: Characteristics of neonatal tracheal intubations (TI) may vary between the neonatal intensive care unit (NICU) and delivery room (DR). The impact of the setting on TI outcomes is not well characterized. Objective: The aim of this study was to define variation in neonatal TI practice between settings, and identify the association between setting and TI success and safety outcomes. Design: This was a retrospective cohort study of TIs in the National Emergency Airway Registry for Neonates from October 2014 to September 2017. The setting (NICU vs. DR) was the exposure of interest. The outcomes were first attempt success, course success, success within 4 attempts, adverse TI-associated events, severe desaturation, and bradycardia. We compared TI characteristics and outcomes between settings in univariable analysis. Factors significant in univariable analysis (p < 0.1) were included in a logistic regression model, with adjustment for clustering by center, to identify the independent impact of the setting on TI outcomes. Results: There were 3,145 TI encounters (2279 NICU, 866 DR) in 9 centers. Almost all baseline characteristics significantly varied between settings. First attempt success rates were 48% (NICU) and 46% (DR). In multivariable analysis, the setting was not associated with first attempt success. DR was associated with a higher adjusted OR (aOR) of success within 4 attempts (1.48, 95% CI 1.06–2.08) and a lower aOR for bradycardia (0.43, 95% CI 0.26–0.71). Conclusion: Significant differences in patient, provider, and practice characteristics exist between NICU and DR TIs. There is substantial room for improvement in first attempt success rates. These results suggest interventions to improve safety and success need to be targeted to the distinct setting.

1.
Falck
AJ
,
Escobedo
MB
,
Baillargeon
JG
,
Villard
LG
,
Gunkel
JH
,
Objective
A
.
Proficiency of pediatric residents in performing neonatal endotracheal intubation
.
Pediatrics
.
2003
Dec
;
112
(
6 Pt 1
):
1242
7
.
[PubMed]
0031-4005
2.
Leone
TA
,
Rich
W
,
Finer
NN
.
Neonatal intubation: success of pediatric trainees
.
J Pediatr
.
2005
May
;
146
(
5
):
638
41
.
[PubMed]
0022-3476
3.
O’Shea
JE
,
Thio
M
,
Kamlin
CO
,
McGrory
L
,
Wong
C
,
John
J
, et al.
Videolaryngoscopy to Teach Neonatal Intubation: A Randomized Trial
.
[Internet]
.
Pediatrics
.
2015
Nov
;
136
(
5
):
912
9
. Available from: http://pediatrics.aappublications.org/cgi/doi/10.1542/peds.2015-1028
[PubMed]
0031-4005
4.
Lane
B
,
Finer
N
,
Rich
W
.
Duration of intubation attempts during neonatal resuscitation
.
J Pediatr
.
2004
Jul
;
145
(
1
):
67
70
.
[PubMed]
0022-3476
5.
O’Donnell
CP
,
Kamlin
CO
,
Davis
PG
,
Morley
CJ
.
Endotracheal intubation attempts during neonatal resuscitation: success rates, duration, and adverse effects
.
[Internet]
.
Pediatrics
.
2006
Jan
;
117
(
1
):
e16
21
. Available from: http://pediatrics.aappublications.org/cgi/doi/10.1542/peds.2005-0901
[PubMed]
0031-4005
6.
Moussa
A
,
Luangxay
Y
,
Tremblay
S
,
Lavoie
J
,
Aube
G
,
Savoie
E
, et al.
Videolaryngoscope for Teaching Neonatal Endotracheal Intubation: A Randomized Controlled Trial
.
[Internet]
.
Pediatrics
.
2016
Mar
;
137
(
3
):
e20152156
20152156
. Available from: http://pediatrics.aappublications.org/cgi/doi/10.1542/peds.2015-2156
[PubMed]
0031-4005
7.
Hatch
LD
,
Grubb
PH
,
Lea
AS
,
Walsh
WF
,
Markham
MH
,
Whitney
GM
, et al.
Endotracheal Intubation in Neonates: A Prospective Study of Adverse Safety Events in 162 Infants
.
J Pediatr
.
2016
Jan
;
168
:
62
6.e6
.
[PubMed]
0022-3476
8.
Foglia
EE
,
Ades
A
,
Napolitano
N
,
Leffelman
J
,
Nadkarni
V
,
Nishisaki
A
.
Factors Associated with Adverse Events during Tracheal Intubation in the NICU
.
Neonatology
.
2015
;
108
(
1
):
23
9
.
[PubMed]
1661-7800
9.
Venkatesh
V
,
Ponnusamy
V
,
Anandaraj
J
,
Chaudhary
R
,
Malviya
M
,
Clarke
P
, et al.
Endotracheal intubation in a neonatal population remains associated with a high risk of adverse events
.
Eur J Pediatr
.
2011
Feb
;
170
(
2
):
223
7
.
[PubMed]
0340-6199
10.
Langhan
ML
,
Emerson
BL
,
Nett
S
,
Pinto
M
,
Harwayne-Gidansky
I
,
Rehder
KJ
, et al.;
for Pediatric Acute Lung Injury and Sepsis Investigators (PALISI) and National Emergency Airway Registry for Children (NEAR4KIDS) Investigators
.
End-Tidal Carbon Dioxide Use for Tracheal Intubation: Analysis From the National Emergency Airway Registry for Children (NEAR4KIDS) Registry
.
Pediatr Crit Care Med
.
2018
Feb
;
19
(
2
):
98
105
.
[PubMed]
1529-7535
11.
Gradidge
EA
,
Bakar
A
,
Tellez
D
,
Ruppe
M
,
Tallent
S
,
Bird
G
, et al.;
National Emergency Airway Registry for Children (NEAR4KIDS) and Pediatric Acute Lung Injury and Sepsis Investigators (PALISI)
.
Effect of location on tracheal intubation safety in cardiac disease-are cardiac ICUs safer?
Pediatr Crit Care Med
.
2018
Mar
;
19
(
3
):
218
27
.
[PubMed]
1529-7535
12.
Haubner
LY
,
Barry
JS
,
Johnston
LC
,
Soghier
L
,
Tatum
PM
,
Kessler
D
, et al.
Neonatal intubation performance: room for improvement in tertiary neonatal intensive care units
.
[Internet]
.
Resuscitation
.
2013
Oct
;
84
(
10
):
1359
64
.
[PubMed]
0300-9572
13.
Hatch
LD
,
Grubb
PH
,
Lea
AS
,
Walsh
WF
,
Markham
MH
,
Whitney
GM
, et al.
Endotracheal Intubation in Neonates: A Prospective Study of Adverse Safety Events in 162 Infants
.
[Internet]
.
J Pediatr
.
2016
Jan
;
168
:
62
6.e6
.
[PubMed]
0022-3476
14.
Venkatesh
V
,
Ponnusamy
V
,
Anandaraj
J
,
Chaudhary
R
,
Malviya
M
,
Clarke
P
, et al.
Endotracheal intubation in a neonatal population remains associated with a high risk of adverse events
.
Eur J Pediatr
.
2011
Feb
;
170
(
2
):
223
7
.
[PubMed]
0340-6199
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.