Background: The fetal-to-neonatal transition is a complex process that includes changes in cardiac and respiratory systems. Objective: The aim of this study is to review the different methods of cardiocirculatory monitoring during the immediate neonatal transition period. Methods: A systematic search of PubMed and Ovid Embase was performed using the following terms: infant, newborn, newborn infant, neonate, neonates, heart, cardiac, blood pressure, haemodynamic, hemodynamics, blood circulation, circulation, echocardiography, ultrasonography, sonography, electrocardiography, ECG, oximetry, pulse, pulse oximetry, monitoring, measurement, acclimatization, adaptation, transition, after birth and delivery room. Additional articles were identified by manual search of cited references. Only human studies describing cardiocirculatory monitoring during the first 15 min after birth were included. Results: Thirteen studies were identified that described heart rate (HR). Additional five studies were identified that measured blood pressure. Four studies performed functional echocardiography during neonatal transition; two in addition to blood pressure monitoring and three in addition to HR monitoring. Conclusion: Routine HR monitoring using electrocardiography or pulse oximetry is used to evaluate adequate hemodynamic transition, and reference ranges have been established. Measuring blood pressure noninvasively though noncontinuously might be of some value in future, considering that the normative data have been established recently. Echocardiographic monitoring during the immediate transition period will improve the knowledge about cardiac function changes, but introduction in clinical routine remains questionable. © 2014 S. Karger AG, Basel

1.
Rudolph AM: Fetal and neonatal pulmonary circulation. Annu Rev Physiol 1979;41:383-395.
2.
Noori S, Stavroudis TA, Seri I: Systemic and cerebral hemodynamics during the transitional period after premature birth. Clin Perinatol 2009;36:723-736, v.
3.
Apgar V: A proposal for a new method of evaluation of the newborn infant. Curr Res Anesth Analg 1953;32:260-267.
4.
O'Donnell CP, Kamlin CO, Davis PG, Carlin JB, Morley CJ: Clinical assessment of infant colour at delivery. Arch Dis Child Fetal Neonatal Ed 2007;92:F465-F467.
5.
O'Donnell CP, Kamlin CO, Davis PG, Carlin JB, Morley CJ: Interobserver variability of the 5-minute Apgar score. J Pediatr 2006;149:486-489.
6.
Richmond S, Wyllie J: European Resuscitation Council Guidelines for Resuscitation 2010 Section 7. Resuscitation of babies at birth. Resuscitation 2010;81:1389-1399.
7.
Kattwinkel J, Perlman JM, Aziz K, Colby C, Fairchild K, Gallagher J, Hazinski MF, Halamek LP, Kumar P, Little G, McGowan JE, Nightengale B, Ramirez MM, Ringer S, Simon WM, Weiner GM, Wyckoff M, Zaichkin J: Part 15: neonatal resuscitation: 2010 American Heart Association guidelines for cardiopulmonary resuscitation and emergency cardiovascular care. Circulation 2010;122:S909-S919.
8.
Wyllie J, Perlman JM, Kattwinkel J, Atkins DL, Chameides L, Goldsmith JP, Guinsburg R, Hazinski MF, Morley C, Richmond S, Simon WM, Singhal N, Szyld E, Tamura M, Velaphi S; Neonatal Resuscitation Chapter Collaborators: Part 11: neonatal resuscitation: 2010 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science with Treatment Recommendations. Resuscitation 2010;81(suppl 1):e260-e287.
9.
Moher D, Liberati A, Tetzlaff J, Altman DG; PRISMA Group: Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. Int J Surg 2010;8:336-341.
10.
Brady JP, James LS: Heart rate changes in the fetus and newborn infant during labor, delivery, and the immediate neonatal period. Am J Obstet Gynecol 1962;84:1-12.
11.
van Vonderen JJ, Roest AA, Siew ML, Blom NA, van Lith JM, Walther FJ, Hooper SB, Te Pas AB: Noninvasive measurements of hemodynamic transition directly after birth. Pediatr Res 2014;75:448-452.
12.
van Vonderen JJ, Te Pas AB, Kolster-Bijdevaate C, van Lith JM, Blom NA, Hooper SB, Roest AA: Non-invasive measurements of ductus arteriosus flow directly after birth. Arch Dis Child Fetal Neonatal Ed 2014;99:F408-F412.
13.
Meier-Stauss P, Bucher HU, Hurlimann R, Konig V, Huch R: Pulse oximetry used for documenting oxygen saturation and right-to-left shunting immediately after birth. Eur J Pediatr 1990;149:851-855.
14.
Kamlin CO, Dawson JA, O'Donnell CP, Morley CJ, Donath SM, Sekhon J, Davis PG: Accuracy of pulse oximetry measurement of heart rate of newborn infants in the delivery room. J Pediatr 2008;152:756-760.
15.
Toth B, Becker A, Seelbach-Gobel B: Oxygen saturation in healthy newborn infants immediately after birth measured by pulse oximetry. Arch Gynecol Obstet 2002;266:105-107.
16.
Kopotic RJ, Lindner W: Assessing high-risk infants in the delivery room with pulse oximetry. Anesth Analg 2002;94:S31-S36.
17.
Dawson JA, Kamlin CO, Wong C, Te Pas AB, O'Donnell CP, Donath SM, Davis PG, Morley CJ: Oxygen saturation and heart rate during delivery room resuscitation of infants <30 weeks' gestation with air or 100% oxygen. Arch Dis Child Fetal Neonatal Ed 2009;94:F87-F91.
18.
Gonzales GF, Salirrosas A: Pulse oxygen saturation and neurologic assessment in human neonates after vaginal and cesarean delivery. Int J Gynaecol Obstet 1998;63:63-66.
19.
Dawson JA, Kamlin COF, Wong C, Te Pas AB, Vento M, Cole TJ, Donath SM, Hooper SB, Davis PG, Morley CJ: Changes in heart rate in the first minutes after birth. Arch Dis Child Fetal Neonatal Ed 2010;95:F177-F181.
20.
Noori S, Wlodaver A, Gottipati V, McCoy M, Schultz D, Escobedo M: Transitional changes in cardiac and cerebral hemodynamics in term neonates at birth. J Pediatr 2012;160:943-948.
21.
Smit M, Dawson JA, Ganzeboom A, Hooper SB, van Roosmalen J, Te Pas AB: Pulse oximetry in newborns with delayed cord clamping and immediate skin-to-skin contact. Arch Dis Child Fetal Neonatal Ed 2014;99:F309-F314.
22.
Bustos R, Bejar R, Arroyave H, Jacomo AJ, Burghi M, Ramirez F, Cordano MC, Curbelo V, Guayasamin O, Minetti R, Guemberena L, Caldeyro-Barcia R: Heart rate in fetuses and neonates in normal conditions and with mild depression. J Perinat Med 1975;3:172-179.
23.
Marx GF, Cabe CM, Kim YI, Eidelman AI: Neonatal blood pressures. Anaesthesist 1976;25:318-322.
24.
Salihoglu O, Can E, Beskardes A, Koc BS, LhanTan I, Can G, Hatipoglu S: Delivery room blood pressure percentiles of healthy, singleton, liveborn neonates. Pediatr Int 2012;54:182-189.
25.
Winberg P, Jansson M, Marions L, Lundell BP: Left ventricular output during postnatal circulatory adaptation in healthy infants born at full term. Arch Dis Child 1989;64:1374-1378.
26.
Pichler G, Cheung PY, Binder C, O'Reilly M, Schwaberger B, Aziz K, Urlesberger B, Schmolzer GM: Blood pressure in term and preterm infants immediately after birth. Abstract E-PAS 2014:4655.4.
27.
Bhatt S, Alison BJ, Wallace EM, Crossley KJ, Gill AW, Kluckow M, Te Pas AB, Morley CJ, Polglase GR, Hooper SB: Delaying cord clamping until ventilation onset improves cardiovascular function at birth in preterm lambs. J Physiol 2013;591:2113-2126.
28.
Yam CH, Dawson JA, Schmolzer GM, Morley CJ, Davis PG: Heart rate changes during resuscitation of newly born infants <30 weeks gestation: An observational study. Arch Dis Child Fetal Neonatal Ed 2011;96:F102-F107.
29.
Palme-Kilander C, Tunell R: Pulmonary gas exchange during facemask ventilation immediately after birth. Arch Dis Child 1993;68:11-16.
30.
Katheria A, Rich W, Finer N: Electrocardiogram provides a continuous heart rate faster than oximetry during neonatal resuscitation. Pediatrics 2012;130:e1177-e1181.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.