Background/Objective: To investigate the therapeutics of heparin-free hemodialysis (HD) with the inside of hollow fibers in a dialyzer coated with human albumins (HFHd-A1). Methods: Clinical contrast study between HFHd-A1 and heparin-free HD with hollow fibers in dialyzer by normal saline flush (HFHd-NS) was performed by adopting the cross-over design method. The dialysis effect, the effect on life signs, blood platelet functions, change of dialyzer fiber-bundle volume, appearance image, and image of scanning electron microscopy of the inside of hollow fibers in dialyzer after dialysis and the biocompatibility of dialyzer of two HD methods were compared. Results: HFHd-A1 could overcome all shortcomings of HFHd-NS and had more merits and increased expenses for HFHd-A1 were not high. Conclusion: HFHd-A1 was an effective and feasible method which could salvage patients with bleeding diseases or bleeding tendency and who need HD.

1.
Wang Xiaoyun: The bleeding complication and anticoagulation treatment for 8016 time HDs. Jiangsu Medicine 1989;1:9.
2.
Ludlow MK: Heparin-free dialysis. ANNA J 1980;16:295.
3.
Geary DF: Low-dose and heparin-free hemodialysis in children. Pediatr Nephrol 1991;5:220.
4.
Gao Xiulin, Liu Huilian: The comparison of the biocompatibility of Acetate fibers membrane dialyzers and Cuprophan membrane dialyzers. Chin J Dial Artif Organs 1991;2:8–11.
5.
Liao Liudan: Clinical report of repetitive use of hollow fiber dialyzers. Chin J Organs Transplant 1985;6:14–16.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.