Tandem scanning confocal microscopy (TSCM) is a noninvasive form of vital microscopy that can be used to evaluate superficial uriniferous tubules in living kidneys. Because TSCM has a number of advantages over conventional microscopic examination of renal biopsies, the present study was undertaken to determine whether the histopathological images obtained by TSCM correlate with post-transplant renal function. The kidneys of New Zealand male rabbits were harvested, flushed with Euro-Collins solution, and stored at 0–2°C for periods of 24, 48, 67 and 72 h prior to transplantation. TSCM observation of the kidneys prior to their transplantation revealed characteristic histopathological changes of the superficial proximal convoluted tubules that correlated closely with subsequent post-transplant renal function. These observations indicate that TSCM may be of significant value in evaluating the status of donor kidneys prior to their transplantation.

1.
Szostek M, Danielewicz R, Lagiewska B, Pacholczyk M, Rybicki Z, Michalak, Adadynski L, Walaszewski J, Rowinski W: Successful transplantation of kidneys harvested from cadaver donors at 71 to 259 minutes following cardiac arrest. Transplant Proc 1995;27:2901–2902.
2.
Peters TG, Shaver TR, Ames JE, Eduardo AS, Jones KW, Blanton JW: Cold ischemia and outcome in 17,937 cadaveric kidney transplants. Transplantation 1995;59:191–196.
3.
Daemen JHC, Heineman E, Kootstra G: Viability assessment of non-heart-beating donor kidneys during machine preservation. Transplant Proc 1995;27:2906–2908.
4.
Andrews PM: Noninvasive vital microscopy to monitor tubular necrosis of cold-stored Kidneys. Transplantation 1994;57:1143–1148.
5.
Kootstra G: First International Workshop on Non-Beating Donors. Transplant Proc 1995;27:2890–2965.
6.
Glaumann B, Trump BF: Studies on the pathogenesis of ischemic cell injury. III. Morphological changes of the proximal pars recta tubules (P3) of the rat kidney made ischemic in vivo. Virchows Arch B Cell Pathol 1975;19:303–323.
7.
Venkatachalam MA, Bernard DB, Donohoe JF, Norman GL: Ischemic damage and repair in the rat proximal tubule: Differences among the S1, S2, and S3 segments. Kidney Int 1978;14:31–49.
8.
Harvig B, Engberg A, Ericsson JLE: Effects of cold ischemia on the preserved and transplant rat kidney. Structural changes of the proximal tubule. Virchows Arch B Cell Pathol 1980;34:153–171.
9.
Brezis M, Rosen S, Silva P, Epstein FH: Renal ischemia: A new perspective. Kidney Int 1984;26:373–383.
10.
Mason J: The pathophysiology of ischemic acute renal failure. A new hypothesis about the initiation phase. Renal Physiol 1986;9:129–147.
11.
Squifflet JP, Pirson Y, Gianello P, Van Cangh P, Alexandra GPJ: Safe preservation of human renal cadaver transplant by Euro-Collins solution up to 50 hours. Transplant Proc 1981;13:693–696.
12.
Khirabadi BS, Fahy GM: Cryopreservation of the mammalian kidney. I. Transplantation of rabbit kidneys perfused with EC and RPS-2 at 2–4°C. Cryobiology 1994;31:10–25.
13.
Petran M, Hadravsky M, Egger MD, Galambos R: Tandem scanning reflected light microscope. J Opt Soc Am 1968;58:661–664.
14.
Andrews PM, Coffey AK: Factors which improve the preservation of nephron morphology during cold storage. Lab Invest 1982;46:100–120.
15.
Coffey AK, Andrews PM: Ultrastructure of kidney preservation: Varying the amount of an effective osmotic agent in isotonic and hypertonic preservation solutions. Transplantation 1983;35:136–143.
16.
Maunsbach AB: Observation on the segmentation of the proximal tubule in the rat kidneys. J Ultrastruct Res 1966;16:239–258.
17.
Maunsbach AB: Influence of different fixatives and fixation methods on the ultrastructure of rat kidney proximal tubules cells. I. Comparison of different perfusion fixation methods and of glutaraldehyde, formaldehyde and osmium tetroxide fixatives. J Ultrastruct Res 1966;15:242–282.
18.
Stubenitsky BM, Booster MH, Brasile L, Haisch CE, Singh HK, Jacobs RWA, Breugelmans ACJ, Koostra G: Prospective evaluation of renal function. Transplant Proc 2000;32:175–176.
19.
Light J: Viability testing in the non-heart-beating donor. Transplant Proc 2000;32:179–181.
20.
Sheppard CJR: Axial resolution of confocal fluorescence microscopy. J Microsc 1989;154:237–241.
21.
Jester JV, Andrews PM, Petroll WM, Lemp MA, Cavanagh HD: In vivo, real-time confocal imaging. J Electron Microsc Tech 1991;18:50–60.
22.
Boyde A: Applications of tandem scanning reflected light microscopy and three-dimensional imaging. Ann NY Acad Sci 1986;483:428–439.
23.
Lemp MA, Shields WM, Essepian J, Mathers W: The clinical use of tandem scanning confocal microscopy of the cornea (abstract). Invest Ophthal Vis Sci 1999;33(suppl):1234.
24.
Ichijima H, Ohashi J, Petroll WM, Cavanagh HD: Morphological and biochemical evaluation for rigid gas-permeable contact lens extended wear on rabbit corneal epithelium. CLAO J 1993;19:120–128.
25.
Ichijima H, Petroll WM, Jester JV, Barry PA, Andrews PM, Dai M, Cavanagh HD: In vivo confocal microscopic studies of endothelial wound healing in rabbit cornea. Cornea 1993;12:369–378.
26.
Cavanagh HD, Petroll WM, Alizadeh, He JG, McCulley JP, Jester JV: Clinical and diagnostic use of in vivo confocal microscopy in patients with corneal disease. Ophthalmology 1993;100:1444–1454.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.