Background: Fat mass (FM) is measured with dual-energy X-ray absorptiometry (DXA), but is expensive and not portable. Multifrequency bioimpedance spectroscopy (BIS) measures total body water (TBW), intracellular water (ICW) and extracellular water (ECW). FM is calculated by subtracting fat-free mass (FFM) from weight assuming a fractional hydration of FFM of 0.73. Hemodialysis (HD) patients, however, have nonphysiologic expansion of ECW. Our aim was to apply a model to estimate FM in HD patients and controls. Methods: We estimated the hydration of FFM in healthy subjects and HD patients with BIS (Impedimed multifrequency) assuming a hydration of 0.73 or using a model allowing ECW and ICW to vary, deriving a value for FM accounting for variances in ECW and ICW. FM was measured by DXA (Hologic Discovery W) in 25 controls and in 11 HD patients. We measured TBW, ECW and ICW with BIS and calculated FM using either weight - TBW/0.73 or with a model accounting for variations in ECW/ICW to estimate FM. Results: ECW/ICW was greater in HD patients than in controls (0.83 ± 0.08 vs. 0.76 ± 0.04; p = 0.001). FM (kg) measured by DXA or estimated from TBW using constant hydration or accounting for variations in ECW/ICW was not significantly different in controls or in HD patients. Values obtained by all methods correlated (p < 0.001) and none of the Bland-Altman plots regressed (r2 = 0.00). FM measured by DXA and by BIS in both controls and HD patients combined correlated (r2 = 0.871). Conclusion: Expansion of ECW in HD patients is statistically significant; however, the effect on hydration of FFM was insufficient to cause significant deviation from values derived using a hydration value of 0.73 within the range of expansion of ECW in the HD patient population studied here.

1.
Muscaritoli M, Molfino A, Bollea MR, Rossi Fanelli F: Malnutrition and wasting in renal disease. Curr Opin Clin Nutr Metab Care 2009;12:378-383.
2.
Bossola M, Muscaritoli M, Tazza L, Giungi S, Tortorelli A, Rossi Fanelli F, Luciani G: Malnutrition in hemodialysis patients: what therapy? Am J Kidney Dis 2005;46:371-386.
3.
Garibotto G, Bonanni A, Verzola D: Effect of kidney failure and hemodialysis on protein and amino acid metabolism. Curr Opin Clin Nutr Metab Care 2012;15:78-84.
4.
Shizgal HM: Nutritional assessment with body composition measurements by multiple isotope dilution. Infusionstherapie 1990;17:9-17.
5.
Sheng HP, Huggins RA: A review of body composition studies with emphasis on total body water and fat. Am J Clin Nutr 1979;32:630-647.
6.
Schoeller DA: Hydrometry; in Roche AF, Heymsfield SB, Lohman TG (eds): Human Body Composition. Champaign, Human Kinetics, 1996, pp 25-44.
7.
Schmidt-Nielsen K: Why is Animal Size So Important? Cambridge, Cambridge University Press, 1984.
8.
Ellis KJ: Reference man and woman more fully characterized: validations on the basis of body size, age, and race. Biol Trace Elem Res 1990;26-27:385-400.
9.
Wang Z, Deurenberg P, Wang W, Pietrobelli A, Baumgartner RN, Heymsfield SB: Hydration of fat-free body mass: new physiological modeling approach. Am J Physiol Endocrinol Metab 1999;276:E995-E1003.
10.
Houtkooper LB, Lohman TG, Going SB, Howell WH: Why bioelectrical impedance analysis should be used for estimating adiposity. Am J Clin Nutr 1996;64:436-448.
11.
Woodrow G, Oldroyd B, Turney JH, Day JME, Smith MA: Measurement of total body water by bioelectrical impedance in chronic renal failure. Eur J Clin Nutr 1996;50:676-681.
12.
Pastan S, Gassensmith C: Total body water measured by bioelectrical impedance in patients after hemodialysis: comparison with urea kinetics. ASAIO J 1992;98:M186-M189.
13.
Scanferla F, Landini S, Fracasso A, Morachiello P, Righetto F, Toffoletto PP, Bazzato C: On-line bioelectric impedance during hemodialysis: monitoring of body fluids and cell membrane status. Nephrol Dial Transplant 1990;5(suppl 1):167-170.
14.
Matthie J, Zarowitz B, De Lorenzo A, Andreoli A, Katzarski K, Pan G, Withers P: Analytic assessment of the various bioimpedance methods used to estimate body water. Appl Physiol 1998;84:1801-1816.
15.
Ellis KJ, Bell SJ, Chertow GM, Chumlea WC, Knox TA, Kotler DP, Lukaski HC, Schoeller DA: Bioelectrical impedance methods in clinical research: a follow-up to the NIH Technology Assessment Conference. Nutrition 1999;15:874-880.
16.
Hannan WJ, Cowen SJ, Plester CE, Fearon KCH, DeBeau A: Comparision of bio-impedance spectroscopy and multi-frequency bio-impedance analysis for the assessment of extracellular and total body water in surgical patients. Clin Sci 1995;89:651-658.
17.
Dou Y, Liu L, Cheng X, Cao L, Zuo L: Comparison of bioimpedance methods for estimating total body water and intracellular water changes during hemodialysis. Nephrol Dial Transplant 2011;26:3319-3324.
18.
Zhu F, Kuhlmann MK, Kaysen GA, Sarkar S, Kaitwatcharachai C, Khilnani R, Stevens L, Leonard EF, Wang J, Heymsfield S, Levin NW: Segment-specific resistivity improves body fluid volume estimates from bioimpedance spectroscopy in hemodialysis patients. J Appl Physiol 2006;100:717-724.
19.
Kakiya R, Shoji T, Tsujimoto Y, Tatsumi N, Hatsuda S, Shinohara K, Kimoto E, Tahara H, Koyama H, Emoto M, Ishimura E, Miki T, Tabata T, Nishizawa Y: Body fat mass and lean mass as predictors of survival in hemodialysis patients. Kidney Int 2006;70:549-556.
20.
Huang CX, Tighiouart H, Beddhu S, Cheung AK, Dwyer JT, Eknoyan G, Beck GJ, Levey AS, Sarnak MJ: Both low muscle mass and low fat are associated with higher all-cause mortality in hemodialysis patients. Kidney Int 2010;77:642-629.
21.
Silva AM, Heymsfield SB, Gallagher D, Albu J, Pi-Sunyer XF, Pierson RN, Wang J, Heshka S, Sardinha LB, Wang Z: Evaluation of between-methods agreement of extracellular water measurements in adults and children. Am J Clin Nutr 2008;88:315-323.
22.
Wang Z, Deurenberg P, Wang W, Pietrobelli A, Baumgartner RN, Heymsfield SB: Hydration of fat-free body mass: review and critique of a classic body-composition constant. Am J Clin Nutr 1999;69:833-841.
23.
Lesser GT, Markofsky J: Body water compartments with human aging using fat-free mass as the reference standard. Am J Physiol 1979;236:R215-R220.
24.
Locatelli F, Fouque D, Heimburger O, Drüeke TB, Cannata-Andía JB, Hörl WH, Ritz E: Nutritional status in dialysis patients: a European consensus. Nephrol Dial Transplant 2002;17:563-572.
25.
Van den Ham ECH, Kooman JP, Christiaans MHL, Nieman FH, Van Kreel BK, Heidendal GA, Van Hooff JP: Body composition in renal transplant patients: bioimpendance analysis compared to isotope dilution, dual energy X-ray absorptiometry, and anthropometry. J Am Soc Nephrol 1999;10:1067-1079.
26.
Woodrow G, Oldroyd B, Wright A, Coward WA, Turney JH, Brownjohn AM, Smith MA, Truscott JG: Abnormalities of body composition in peritoneal dialysis patients. Perit Dial Int 2004;24:169-175.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.