Objectives: The aim of this prospective study was to assess the accuracy of 64-multidetector-row computed tomography coronary angiography (CTA) in the diagnosis of coronary artery disease (CAD). Patients and Methods: Ninety-two patients suspected of having CAD underwent CTA using a 64-slice CT scanner before a scheduled, conventional coronary angiogram (CCA). Blinded assessment of CTA to detect CAD was performed. The accuracy of CTA in detecting significant stenoses (≥50%) was compared to CCA. Data analysis was performed on 73 patients because the scans were nondiagnostic in 5 patients and 14 refused to undergo coronary angiography. Results: The CTAs of 21 of these 73 patients were considered as normal; 19 were confirmed on CCA. For the remaining 52 diagnosed as abnormal, 51 were confirmed on CCA. For patient-based analysis, CTA had a sensitivity of 95%, a specificity of 96%, a positive predictive value of 98% and a negative predictive value of 90%. For the whole vessel, the sensitivity of CTA was 60–100%, for all vessels and the specificity was 82–100%. Pooled sensitivity was 92% and pooled specificity was 98%. For the segments, the sensitivity of CTA was 64% or above for all vessels except for the distal left anterior descending artery (40%), mid circumflex artery (50%) and posterior descending artery (60%); the pooled sensitivity was 79%. The specificity for the segments was 82–100% for all vessels and pooled specificity was 94%. Conclusion: The sensitivity and specificity for patient-based analysis and for the main coronary vessels were high whereas for the segments, the sensitivity was moderately good, but the specificity was high, confirming that a negative CTA is useful to rule out significant CAD. A coordinated classification system between radiologists and cardiologists is required to eliminate errors in segment classification.

This content is only available via PDF.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.