Arteriovenous anastomoses (AVA) in skin microcirculation are mediated by the sympathetic stimuli. The inspiratory gasp test (IG test) triggers the sympathetic nervous system, resulting in a decrease in AVA skin blood flow, as measured by laser Doppler fluxmetry (LDF). We studied the reproducibility of the IG test under carefully standardized respiratory conditions. In each of 19 healthy (young) volunteers with a mean skin temperature during the experiment above 28°C 13 IG tests were performed, either under spirometric control or uncontrolled and by using a negative pressure transducer. Starting the IG test end-inspiratory results in the most pronounced absolute LDF decrease [140 PU (70-490)], median (minimum-maximum) as compared to starting end-expiratory [100 PU (40-260)] and during inspiration [110 PU (50-350)], respectively, p < 0.001 and p < 0.01. Inspiration as fast as possible results in a larger absolute LDF decrease [150 PU (40-450)], compared to inspiration in 5 s [120 PU (60-340); p < 0.02] and in 10 s [130 PU (40-350); p < 0.05]. Continuously sucking negative mouth pressure results in a larger LDF decrease [140 PU (30-420)] in comparison with taking one deep breath and holding it for 10 s [110 PU (30-270); p < 0.01]. However, standardization of the IG test did not improve its reproducibility.

This content is only available via PDF.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.