Introduction: Telestroke videoconference for conducting the National Institute of Health Stroke Scale (NIHSS) is recommended when the facility of a direct bedside evaluation by a stroke specialist is not immediately available for hyperacute stroke assessment. However, some NIHSS-telestroke studies inherit systematic bias due to the subjective nature of NIHSS administration. We aimed to evaluate NIHSS telestroke assessment, while implementing measures to minimize subjectivity bias. Patients and Methods: Ninety stroke patients within 48 h of onset were assessed by 6 stroke neurologists grouped in 15 pairs. Each pair of physicians assessed 6 patients. Patients were allocated through block randomization to a physician pair and order of bedside or remote assessment. Every patient was assessed once at the bedside and once remotely. Remote examination was performed by a neurologist through high-quality videoconferencing (HQ-VTC), assisted by a nurse at the patient's bedside. Kappa coefficients and the number of patients with a cumulative difference of ≤3 NIHSS points were calculated to compare bedside and remote measures. Results: Cumulative difference of ≤3 NIHSS points was observed in 85.6% (95% CI 76.6-92.1%) cases. Therefore, every fifth remote examination may have been inaccurate. Quadratically weighted kappa for total NIHSS score was 0.91 (95% CI 0.87-0.95). Minimal agreements were for commands (k = 0.46), facial palsy (k = 0.43), and ataxia (k = 0.27). Remote assessments were longer than bedside: 8 min (interquartile range, IQR 7-9) vs. 6 (IQR 5-8), p < 0.001. Conclusions: NIHSS-telestroke assessment using HQ-VTC in the acute stroke settings is closely matched with NIHSS-bedside assessment but it's credibility for clinical use needs further evaluation.

1.
National Institute of Neurological Disoders and Stroke: Free versions of the NIH Stroke Scale, 2003, www.ninds.nih.gov/doctors/NIH_Stroke_Scale.pdf (accessed January 09, 2015).
2.
Jauch E, Saver JL, Adams HP Jr, et al: Guidelines for the early management of patients with acute ischemic stroke: a guideline for healthcare professionals from the American Heart Association/American Stroke Association. Stroke 2013;44:870-947.
3.
Goldstein L, Bertels C, Davis JN: Interrater reliability of the NIH Stroke Scale. Arch Neurol 1989;46:660-662.
4.
Goldstein LB, Samsa GP: Reliability of the National Institutes of Health Stroke Scale. Extension to non-neurologists in the context of a Clinical Trial. Stroke 1997;28:307-310.
5.
Berthier E, Decavel P, Vuillier F, et al: Review: reliability of NIHSS by telemedicine. Eur Res Telemed 2012;1:111-114.
6.
Schwamm LH, Holloway RG, Amarenco P, et al: A review of the evidence for the use of telemedicine within stroke systems of care: a scientific statement from the American Heart Association/American Stroke Association. Stroke 2009;40:2616-2634.
7.
Shafqat S, Kvedar JC, Guanci MM, et al: Role for telemedicine in acute stroke. Feasibility and reliability of remote administration of the NIH Stroke Scale. Stroke 1999;30:2141-2145.
8.
Handschu R, Littmann R, Reulbach U, et al: Telemedicine in emergency evaluation of acute stroke: interrater agreement in remote video examination with a novel multimedia system. Stroke 2003;34:2842-2846.
9.
Meyer B, Lyden PD, Al-Khoury L, et al: Prospective reliability of the STRokE DOC wireless/site independent telemedicine system. Neurology 2005;64:1058-1060.
10.
Berthier E, Decavel P, Vuillier F, et al: Reliability of NIHSS by telemedicine in non-neurologists. Int J Stroke 2013;8:E11.
11.
Wechsler LR, Demaerschalk BM, Schwamm LH, et al: Telemedicine quality and outcomes in stroke: a scientific statement for healthcare professionals from the American Heart Association/American Stroke Association. Stroke 2017;48:e3-e25.
12.
Zar JH: Biostatistical analysis (5th edition). Upper Saddle River, NJ: Pearson Prentice-Hall, 2010, pp 960.
13.
Sim J, Wright CC: The kappa statistic in reliability studies: use, interpretation, and sample size requirements. Phys Ther 2005;85:257-268.
14.
Van Hooff R, Cambron M, Van Dyck R, et al: Prehospital unassisted assessment of stroke severity using telemedicine: a feasibility study. Stroke 2013;44:2907-2909.
15.
Badaev FI, Alasheev AM, Belkin AA, et al: Pomekhi videokonferentssvyazi vo vremya neiroreanimatsionnykh robotizirovannykh telekonsul'tatsii. Intensivnaya terapiya i anesteziya 2014;1:36-39.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.