Abstract
Background: Semicircular lipoatrophy (SL) is a benign pathology characterized by subcutaneous adipose tissue atrophy. Objective: To determine causes of SL. Methods: We performed research on 42 cases of SL who had developed symptoms of lipoatrophy with a technical study of the building and clinical study of the affected patients. Results: Electromagnetic field and electrostatic charge measurements were performed. No signals different from typical radio, TV and other wireless communication devices were recorded. Electrostatic charges were recorded in floors, environments and on different furniture; they were positive, and all charges disappeared on contact with the worker's skin. Data about the workplace were collected, and clinical examinations were performed, including blood and biochemistry tests and 18 ultrasound skin tests. Conclusions: As no abnormal electromagnetic measurements were found and electrostatic changes and occupational behaviors showed some relevant data and as after changes in order to control the electrostatic environment all of them improved, we can conclude that electrostatic charges but not electromagnetic ones are the main cause of SL.
Introduction
Semicircular lipoatrophy (SL) is a benign and reversible pathology characterized by subcutaneous tissue atrophy, which affects subcutaneous adipose tissue and related structures, and is located mainly in the thigh region [1]. It was first described in 1974 [2,3] and is characterized by the appearance of semicircular bands, unilateral or bilateral, depressed, usually located in the anterior and lateral region of the thigh, and at an approximate height of 72 cm from the ground. SL has occasionally been noted to appear in other areas, such as the forearms [4] or ankles [5]. It affects women more frequently than men, having a ratio of 6:1. However, the higher occurrence in women might be because of greater aesthetic concerns, which lead women to look for a medical solution, or perhaps because female subcutaneous tissue has a predisposition to this particular pathology [6,7]. The etiology of the condition is poorly understood and is probably multifactorial [8,9]. Several hypotheses have been suggested. Some authors, such as Bloch and Runne [10], argue that the cause is an abnormality of the lateral femoral circumflex artery, which when joined with repeated microtrauma can cause ischemic atrophy of fat tissue. This hypothesis is about a very rare abnormality (3% of the population) and therefore cannot be taken into account with respect to the frequent occurrences of SL that have been reported for the last 10 years or so in some office buildings. Another theory explains the lesions as a result of repeated microtrauma in certain jobs [11,12] and a maintained pressure in the affected areas caused by close-fitting clothes [13,14]. SL has also been associated with exposure to electromagnetic fields generated by wires or antennas in the work environment, and the accumulation of electrostatic charges on office devices such as printers, computers and tables. This is suggested to produce changes in intrinsic bioelectric properties of the skin, activating macrophages that produce lipophagia [15,16,17,18].
The designs of new office buildings, with enclosed spaces and large windows (greenhouse effect), make it necessary to use cooling systems that modify the relative humidity. This causes an apparent change in a material's conductivity by the appearance of a surface density electrostatic charge. Low levels of relative humidity favor the presence of such charges. Some authors suggest that these factors could make SL more frequent in newly designed buildings [15,19,20,21,22]. In December 2010, an agreement between the Rey Juan Carlos University and BP Oil Spain was made to study SL, as some workers from the company had developed symptoms of lipoatrophy. This study was carried out in 2 phases. Phase 1 was a technical study of the building, and phase 2 was a clinical study of the affected workers.
Material and Methods
First Phase: Technical Study of the Building
Measurements were taken to check the electromagnetic and electrostatic state of the building. These measurements were developed with an isotropic broad-band antenna (30 MHz to 3 GHz) (model R&S®TS-EMF; Rohde & Schwarz, Munich, Germany) and a Spectrum Handheld Analyzer R&S®FSH-3, and were performed on all floors of the building with greater emphasis on the areas where affected workers were located. Electrostatic charges were measured using an electrostatic meter with a measuring range of ±0-20 kV (model 990.10282®; Electrostática, Barcelona, Spain). All measurements were performed on different floors, in different environments and on different furniture.
Second Phase: Clinical Study
During this phase, volunteer workers who had presented with lesions compatible with lipoatrophy were examined. We conducted exhaustive interviews where we collected personal and family backgrounds, and focused especially on obtaining data about the appearance, location, symptoms, duration and resolution of lesions. Data about the workplace were collected, including posture, use of a footrest when working, type of clothing worn and sensation of discharge when touching some objects. Clinical examinations were performed, including blood and biochemistry tests, and some patients also underwent an ultrasound skin test.
Results
The company had 390 workers in total, 182 male and 208 female; age was similar in both groups; 42 of them had lesions clinically compatible with lipoatrophy (defined as a band of semicircular subcutaneous fat atrophy), mostly located on the anterior surface of the thigh about 75- 80 cm above the ground, except 2 patients whose lesions were about 10 cm above the knee (65 cm above the ground). All those affected were women (table 1). The condition had remitted spontaneously in 24 workers after they had had some holidays and had been away from their workplace (and not submitted to the electrostatic environment of the building), and 18 workers still showed some SL signs.
Electromagnetic field measurements were performed throughout the building during work time focusing on the areas where the affected workers' offices were located. The electromagnetic environment was the same for all the patients. The electrostatic charges measured in different places (workers with SL and workers without SL) were the same everywhere. No signals different from typical radio, TV and other wireless communication devices, such as mobile phones and WiFi (fig. 1), were recorded, and were not at levels above that prescribed by law (fig. 2). Electrostatic charge measurements were recorded as the potential difference generated by the accumulation of the electrostatic charge or ‘volt' on measuring equipment of ±20 kV. All furniture was found to be properly grounded. Measurements of desks showed no electrostatic charge. However, measurements of chairs, both in seats and in rear seat backs, but especially seats, showed an electrostatic charge accumulation (table 2).
Electrostatic charge measurements from different types of footrests were taken. Plastic facilitates generation and accumulation of electrostatic charges more than materials which are coated with a layer of carpet, fabric or felt. Measurements of screens in the workplace were performed, and no electrostatic charge accumulation was found. In most cases, screens were flat screen monitors, which minimize the risk of charges. Electrostatic charges were recorded when measuring the output trays of printers and freshly printed sheets from laser printing equipment and copiers. Charges disappeared on contact with the worker's skin. Carpeted floors were measured, and no significant electrostatic charges were recorded. The antistatic effect of carpet was evident.
As an additional measure, we raised part of the false floor and obtained electrostatic charge data on wiring areas, with no significant values being recorded. We also found no outstanding values after electromagnetic field measurements and concluded that the false floor was electromagnetic field isolated.
The relative humidity in each floor should not be less than 50%. Data from building sensors showed the relative humidity to be routinely closer to 45 than 50%, allowing the consequent risk of an accumulation of electrostatic charges.
On clinical examination we distinguished 2 groups of patients: (1) those who reported lesions which had resolved (n = 24), either spontaneously or because of a change of workplace, and (2) those who had clinical lesions at the time of the study (n = 18). In the latter group, lesions affected the anterior thighs either unilaterally or bilaterally and consisted of linearly depressed areas, which were asymptomatic and had a width of 1-2 cm and a length of 3-7 cm. These lesions were more evident when patients stood up and with deep palpation. For all patients, complete blood counts and biochemical tests were conducted, and all parameters were within normal ranges. Eighteen patients agreed to be examined and underwent ultrasound of the affected skin: 9 showed SL, and 6 also had lipodystrophy (cellulite). The other 9 patients had only lipodystrophy. We decided to treat all 18 patients in the same way with changes in order to control the electroenvironment (table 3), and all of them improved, with remitting SL, and this condition has been maintained until now.
Discussion
The human body is a good conductor of electricity. In environments with low relative humidity, the body can accumulate electrostatic charges, with the potential to reach several thousand volts [23,24,25,26]. The type of clothes worn has a great influence on static electricity generation. For example, silks, wool and synthetic fibers are good producers of static electricity when friction is applied. Shoes, as possible grounding elements, play an important role in this phenomenon [21,27].
Electrostatic discharges higher than 2 kV are felt as an electric shock and give off energy of 0.4 mJ. The use of the human body as a transmitter can be dangerous.
The choice of contact material is critical for the reduction of electrostatic charges generated by contact. It is important to avoid working with materials with very different electron affinities, meaning wide gaps in the triboelectric series (table 4), for example glass and Teflon (polytetrafluorethylene), or polyvinyl chloride and polyamide (nylon).
The magnitude of the electrostatic charge is related to the position or relative distance of the materials to each other in the series, and its sign is determined by the propensity of the material to transfer or gain electrons, which is what indicates the series. Reducing contact pressure between the materials can decrease the electrostatic transfer, with an adequate control of the temperature at the contact surfaces.
In the current study of the working environment we recorded high electrostatic charge levels in chairs, certain footrests and laser printers. The continuous friction between furniture, mostly chairs, and synthetic clothing in an environment with a relative humidity under 50% allowed for the accumulation of high electrostatic charge levels (with a potential of thousands of volts). The human body is an excellent electrical conductor and becomes a perfect way to release accumulated charges, especially through the more compressed areas or those parts of the body which have closer contact with clothes [12]. Clothes commonly worn by workers are made with synthetic fibers, silk, rayon or wool, and facilitate static charge accumulation [13,24,28]. Footwear usually contains rubber and has synthetic soles that do not permit the release of static energy into the ground, hence people remain charged. All these factors contribute to the release of the accumulated electrostatic charge through grounded objects with which the employee has contact, typically the desk [26,29]. The contact usually takes place when the legs touch the underside of the desktop, and the area between the hip and knee is the main place for discharging the charge to the ground. This charge accumulation and discharge phenomenon are repeated continuously throughout the working day.
Energy crossing through body tissue can occur anywhere, but preferentially it happens at surfaces that have higher contact pressure. In women wearing pants, this is the anterior face of the thighs. Pants are more easily adjusted in this region in women compared with men. In addition to this the fat tissue structure is different in women compared to men, and both can be a reason for the higher prevalence of SL being observed in women.
In the current study, 2 workers had lesions about 10 cm above the knee. These workers were the only 2 of all those interviewed who reported the regular use of skirts made of conductive fibers, and the end part of the skirt coincided with the place where the lesions were located. We believe that these lesions were located lower than usually occurs because, in the absence of any pressure area, discharge occurs from the final edge of the piece of clothing. No data were obtained that enabled us to assess whether lipoatrophy was caused by repeated microtrauma produced by the edge of tables, as this situation was not reported by interviewed workers. We believe that the unique reason for the location of lesions is from the highest pressure area of the clothes and the height of tables.
Our study, performed in patients suffering from SL due to adverse conditions in their work environment, supports the hypothesis previously published. Some authors such as Verschaeve and Maes [16] have performed investigations that suggest SL can be caused by ‘electric' phenomena. Other authors [30] have performed studies in vivo with electrostatic discharge, and they conclude that more studies are needed, because it cannot be rejected that the current transfer is directly related to SL. We consider that in the present study, electrostatic energy is the main cause of SL, because we have concluded that removing electrostatic charge generation in the work environment leads to a clinical resolution of lesions and no new cases occur, demonstrating a clear cause-effect relation.
Conclusion
We present a study of SL with both technical measurements of the building and an epidemiological study of the affected workers. The results suggest that people at risk for developing SL are women wearing synthetic clothes, particularly short-sleeved shirts, stretch pants and shoes with rubber synthetic soles. The risk of developing SL at the workplace increases when office furniture does not include grounded desks, chairs are made of material that accumulates electrostatic charges, and the office has low relative humidity conditions.
The mechanism for generating lesions can be explained as follows: the worker is charged when seated on a chair, or when he or she takes a sheet of paper from the laser printer in a dry environment. The person's clothes and shoes are charged, and as they are not conductors, they do not allow for discharge to the ground. Discharge occurs when the worker contacts a grounded object that allows discharge, in this case the underside of the desktop. Clothing discharge is produced through the area where the pressure is highest because of the particular clothes worn, which usually coincides with the anterior region of the thighs.
We believe that the higher prevalence of SL seen in women can be explained, among other genetic reasons, by differences in the type of clothing worn. Men rarely wear stretch clothes and often wear long-sleeved shirts, so the clothes contacting the desktop dispel the electrostatic charge, bypassing the body of the worker.
Acknowledgments
This study was carried out thanks to the collaboration between BP Oil Spain with Rey Juan Carlos University promoted by the Medical Service of BP Oil Spain concerned about the health of their employees.
Disclosure Statement
The authors declare that they have no competing interests.