Background: Assuring adequate antibiotic tissue concentrations at the point of infection, especially in skin and soft tissue infections, is pivotal for an effective treatment and cure. Despite the global issue, a reliable AB monitoring test is missing. Inadequate antibiotic treatment leads to the development of antimicrobial resistances and toxic side effects. β-lactam antibiotics were already detected in sweat of patients treated with the respective antibiotics intravenously before. With the emergence of smartphone-based biosensors to analyse sweat on the spot of need, next-generation molecular digital biomarkers will be increasingly available for a non-invasive pharmacotherapy monitoring. Objective: Here, we investigated if the glycopeptide antibiotic vancomycin is detectable in sweat samples of in-patients treated with intravenous vancomycin. Methods: Eccrine sweat samples were collected using the Macroduct Sweat Collector®. Along every sweat sample, a blood sample was taken. Bio-fluid analysis was performed by Ultra-high Pressure Liquid Chromatograph-Tandem Quadrupole Mass Spectrometry coupled with tandem mass spectrometry. Results: A total of 5 patients were included. Results demonstrate that vancomycin was detected in 5 out of 5 sweat samples. Specifically, vancomycin concentrations ranged from 0.011 to 0.118 mg/L in sweat and from 4.7 to 8.5 mg/L in blood. Conclusion: Our results serve as proof-of-concept that vancomycin is detectable in eccrine sweat and may serve as a surrogate marker for antibiotic tissue penetration. A targeted vancomycin treatment is crucial in patients with repetitive need for antibiotics and a variable antibiotic distribution such as in peripheral artery disease to optimize treatment effectiveness. If combined with on-skin smartphone-based biosensors and smartphone applications, the detection of antibiotic concentrations in sweat might enable a first digital, on-spot, lab-independent and non-invasive therapeutic drug monitoring in skin and soft tissue infections.

Emerging smart biosensors analyse molecular digital biomarkers in sweat directly on patient skin and qualify as the next-generation in point-of-care monitoring [1]. Previous studies demonstrated the detectability of β-lactam antibiotics in sweat [2]. Monitoring antibiotic concentrations at the point-of-need is pivotal to assure therapeutic antibiotic tissue concentrations. A reliable detection method has yet to be developed. The use of molecular digital biomarkers, such as antibiotic concentrations, in sweat is a novel approach to combat antimicrobial resistances, a main global issue in healthcare [1, 3].

Skin and soft tissue infections are characterized by microbial invasions [4]. There has been a 40% increase of skin and soft tissue infections resulting in a 3-fold increase of direct healthcare costs in the USA between 2000 and 2012 [5]. Adapting the standard antimicrobial dosage is pivotal as tissue penetration has been demonstrated to vary significantly between patients [6]. Variation in antibiotic levels between plasma and target site typically results in insufficient antibiotic levels in tissue, which can lead to antimicrobial resistances [7]. Among other, vancomycin has a central role in treating methicillin-resistant staphylococcus aureus. While therapeutic drug monitoring for antibiotics in plasma is associated with a positive clinical outcome, it is invasive, laborious and only provides an estimation of target site concentration. Therapeutic drug monitoring in skin and soft tissue infections has so far only been utilized in research studies (skin blisters and micro-dialysis studies) [8]. A tissue targeted, personalized point-of-care monitoring for antibiotic levels is urgently needed.

Previously, the detection of β-lactam antibiotics in patients’ sweat samples was demonstrated [2]. The antibiotic vancomycin has a high molecular weight and is polar, therefore its appearance in sweat remained unclear. The excretion of vancomycin into sweat is likely to be active through channels. Sweat analysis is currently lab-dependent with limited clinical utility. Smartphone-based biosensors (Fig. 1) could enable on-skin, lab-independent sweat analysis, providing “real-time” digital molecular feedback [1].

Fig. 1.

A novel smart patch by Reeder et al. [10] that analyses sweat directly on the skin (photo credit: P. Gutruf, Northwestern University. Distributed under a CC BY-NC license http://creativecommons.org/licenses/by-nc/4.0/, re-use permission for the picture granted by the American Association for the Advancement of Science (AAAS), Science advances journals).

Fig. 1.

A novel smart patch by Reeder et al. [10] that analyses sweat directly on the skin (photo credit: P. Gutruf, Northwestern University. Distributed under a CC BY-NC license http://creativecommons.org/licenses/by-nc/4.0/, re-use permission for the picture granted by the American Association for the Advancement of Science (AAAS), Science advances journals).

Close modal

We investigated the detectability of the glycopeptide vancomycin in patients’ sweat, and discussed the potential of vancomycin detection in sweat as a digital non-invasive, target site drug monitoring.

Trial design of this observational trial, survey of patient characteristics, Ethics Committee identification number, inclusion and exclusion criteria were previously published in Brasier et al. [2]. Sweat sampling was conducted 6 h after the last intravenous antibiotic dose using the sweat-inducing Macroduct Sweat Collector®. In short, sweat glands were stimulated using pilocarpine iontophoresis, a combination of a local acetylcholine analogue and a local current. Sweat was collected by a capillary container, samples were transported on dried ice and stored at –80°C until analysis. The ClinicalTrials.gov registration number is NCT03678142.

The sweat sample (50 µL) was combined with 50 µL of aminopterin (10 ng/mL in 50% methanol, Toronto Research Chemicals, Canada) as an internal standard and extracted with 0.4 mL of ice-cold methanol. The mixture was vortexed for 10 s and incubated at –20°C overnight, followed by centrifugation at 15,000 g for 20 min (4°C). The supernatant was then dried under a stream of nitrogen. The dried extract was re-suspended in 50 µL of 5% methanol in water and stored at –80°C until analysis. An external calibration curve was prepared by adding various amounts of vancomycin (Clearsynth, NJ, USA) to artificial sweat samples (Pickering Laboratories, CA, USA), followed by extraction as described above. Whole blood samples (50 µL) were combined with 25 µL of aminopterin (1 µg/mL in 50% methanol) and extracted with 610 µL of cold methanol. The supernatant was used directly for UPLC-MS/MS analysis. An external calibration curve was prepared adding various amounts of vancomycin to drug free whole blood matrix followed by extraction. Sample extracts (2 µL) were injected into a UPLC-MS/MS system consisting of a Waters Acquity Classic UPLC coupled with a Waters Xevo TQ-S triple quadrupole mass spectrometer (Milford, MA, USA). Chromatographic separation was performed on a Waters HSS T3 UPLC column (2.1 × 50 mm, 1.8 µM). The column temperature was held at 45°C. Mobile phases consisted of (A) water with 0.1% formic acid and (B) acetonitrile with 0.1% formic acid. The solvent gradient started with 99% A and held for 1 min, increased to 99% B in 1.5 min, equilibrated at 99% B for 1 min. Total run time was 5 min. The mass detector was set in ESI+ mode with 0.6 kV of capillary voltage. The source and desolvation temperatures were 150 and 450°C, respectively. The desolvation gas (N2) flow was 1,000 L/h. The precursor/product ions transitions were chosen based on a previous study [9], 725 > 100, 725 > 144, 725 > 1,306 for vancomycin; 441 > 175, 441 > 294 for aminopterin. The cone voltage and collision energy were optimized using the Intellistart tool in Waters Masslynx software (online suppl. Table S1, see www.karger.com/doi/10.1159/000512947). Two analytical replicates were analyzed for each sample. A pooled quality control sample was repeatedly analyzed to monitor instrument stability (coefficient of variation of 4.8%; n = 12). Peak integration was completed using TargetLynx XS in MassLynx software. The peak area of vancomycin normalized to that of aminopterin was used in the determination of the vancomycin concentration.

Five patients treated with intravenous vancomycin were included. Vancomycin was administered for >24 h in 4/5 patients, and 1/5 patients had an impaired renal function. The patients’ ages varied from 63 to 77 years, weights varied between 57.7 and 130 kg, and the received vancomycin doses ranged from 500 to 1,000 mg (total daily doses from 1,000 to 2,000 mg; Table 1).

Table 1.

Patient characteristics and results

Patient characteristics and results
Patient characteristics and results

Vancomycin was detectable in every sweat and blood sample. The amount of earlier applied doses were 1 × –36 × times (Table 1). Vancomycin concentrations in sweat ranged from 0.011 to 0.118 mg/L and vancomycin was detectable after first intravenous dose, whereas vancomycin concentrations in blood ranged from 4.7 to 8.5 mg/L (Table 1). Vancomycin in sweat was about 0.2–2.5% in relation to blood concentrations. Results across the five patients suggest a positive trend between applied dosage levels and sweat concentrations (Table 1).

To the best of our knowledge, this pilot study represents the first reported detection of vancomycin in patients’ sweat treated with intravenous vancomycin. Vancomycin was detected in all of the sweat samples tested. Vancomycin was detectable in sweat at low levels (0.011 mg/L) in patient 1 that received only a single dose before, in contrast to patient 2 at higher levels (0.118 mg/L) after having received 36 doses. While patient 1 weighed almost half as much as patient 2 (smaller distribution volume), both patients had an adequate renal function (>50 GFR [mL/min/1.73 m2]) and were of a comparable age. We hypothesize that antibiotic concentrations’ steady state arises after the application of multiple doses. Patient 5 (1 dose/day with 750 mg) showed a lower sweat, but a higher blood antibiotic concentration compared to patient 4 (2 doses/day, each 500 mg). We hypothesized that higher single shot doses may lead to an increase in blood concentration, but higher daily doses, applied twice a day may enable a better tissue penetration with subsequent higher sweat concentrations.

If further approved in larger trials, detecting on-spot vancomycin concentrations in sweat may allow to personalize antibiotic treatment in skin and soft tissue infections. This approach could be particularly beneficial for patients with peripheral artery diseases, as vancomycin tissue penetration varies significantly [6]. Overall, adequate antibiotic concentrations above the bacterial minimal inhibitory concentration at the point of infection is essential to prevent from development of antimicrobial resistances or overdosing with a high risk of concomitant toxic side effect [6].

In this pilot study, the sweat analysis was conducted using mass spectrometry, which is a lab-dependent and expensive technology. Clinical utility of this digital biomarker will require development of smart biosensor technology that will enable a non-invasive, on-skin detection (Fig. 1) [1]. Combined with an automated smartphone application, this would enable the dynamic integration of antibiotic concentration measurements with other data such as patient body weight, antibiotic application dose, and bacterial minimal inhibitory concentration. This personalized treatment approach could be applied in-hospital as well as in an outpatient setting, enabling a patient-centred administration of antibiotic drug treatment.

Despite describing a novel promising approach of therapeutic drug monitoring, this study had some limitations. Study sample size was small, sweat was actively induced and collected during 30 min, therefore absolute vancomycin concentrations need to be interpreted carefully. One patient was wrongly recruited despite having an impaired renal function (estimated glomerular filtration rate [eGFR] <50 mL·min–1·1.73 m[2]–1) and one patient was treated with the antibiotic <24 h. Due to the pilot study character, the patients were not excluded retrospectively. Finally, as in patients treated with vancomycin the minimal inhibitory concentrations range in concentrations of about >1 mg/L, the low antibiotic sweat concentrations need to be set in context to clinical outcome and not only to the minimal inhibitory concentration.

In summary, we see a great potential of monitoring vancomycin concentrations in sweat in skin and soft tissue infections. Especially a non-invasive and lab-independent test at the spot of need may help to prevent from antibiotic misuse. Larger trials to proof the detectability as well as the impact on clinical outcome are needed before specific smart sweat sensors are developed.

The author would like to thank S. Purschke and V. Grassedonio from the Department of Clinical Research, University Basel, Switzerland, for their substantial support during patient recruitment.

This research complies with the guidelines for human studies and was conducted ethically in accordance with the World Medical Association Declaration of Helsinki. All patients provided written informed consent. The Ethics Committee of Northwest and Central Switzerland approved this study (EKNZ Reg-ID 2018–01155).

M.O. received a project grant and consulting fees from Pharming Biotechnologies B.V. with regards to a different project. J.E. is holding 0.5% of virtual shares of Preventicus. The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

An “Innovation Pilot Project Grant” from the University Basel, Switzerland, was granted to J.E. and J.P. The sweat collection system were provided at reduced research costs by ELITech Sàrl, Switzerland. ELITech Sàrl did not have any influence in data collection or data analysis anyhow.

N.B., P.B.-L., and J.E. contributed substantially to the conception of the trial. N.B. critically interpreted state-of-the art literature. N.B. and F.D. drafted the manuscript. N.B., A.W., M.O., M.M., F.D., P.B.-L., K.B., L.Y., C.D.B., J.P., and J.E. critically reviewed and finally approved the manuscript version to be published. N.B. and J.E. agreed to be accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and reported.

1.
Brasier
N
,
Eckstein
J
.
Sweat as a Source of Next-Generation Digital Biomarkers
.
Digit Biomark
.
2019
Dec
;
3
(
3
):
155
65
.
[PubMed]
2504-110X
2.
Brasier
N
,
Widmer
A
,
Osthoff
M
,
Mutke
M
,
De Ieso
F
,
Brasier-Lutz
P
, et al.
Non-invasive Drug Monitoring of β-Lactam Antibiotics Using Sweat Analysis-A Pilot Study
.
Front Med (Lausanne)
.
2020
Aug
;
7
(
476
):
476
.
[PubMed]
2296-858X
3.
World Health Organization (WHO)
.
Global action plan on antimicrobial resistance
.
2015
(https://www.who.int/antimicrobial-resistance/global-action-plan/en/). Last accessed 29.08.20.
4.
Ray
GT
,
Suaya
JA
,
Baxter
R
.
Incidence, microbiology, and patient characteristics of skin and soft-tissue infections in a U.S. population: a retrospective population-based study
.
BMC Infect Dis
.
2013
May
;
13
(
1
):
252
.
[PubMed]
1471-2334
5.
Tun
K
,
Shurko
JF
,
Ryan
L
,
Lee
GC
.
Age-based health and economic burden of skin and soft tissue infections in the United States, 2000 and 2012
.
PLoS One
.
2018
Nov
;
13
(
11
):
e0206893
.
[PubMed]
1932-6203
6.
Stein
GE
,
Wells
EM
.
The importance of tissue penetration in achieving successful antimicrobial treatment of nosocomial pneumonia and complicated skin and soft-tissue infections caused by methicillin-resistant Staphylococcus aureus: vancomycin and linezolid
.
Curr Med Res Opin
.
2010
Mar
;
26
(
3
):
571
88
.
[PubMed]
0300-7995
7.
Brunner
M
,
Pernerstorfer
T
,
Mayer
BX
,
Eichler
HG
,
Müller
M
.
Surgery and intensive care procedures affect the target site distribution of piperacillin
.
Crit Care Med
.
2000
Jun
;
28
(
6
):
1754
9
.
[PubMed]
0090-3493
8.
Ray
A
,
Malin
D
,
Nicolau
DP
,
Wiskirchen
DE
.
Antibiotic Tissue Penetration in Diabetic Foot Infections A Review of the Microdialysis Literature and Needs for Future Research
.
J Am Podiatr Med Assoc
.
2015
Nov
;
105
(
6
):
520
31
.
[PubMed]
8750-7315
9.
Brozmanová
H
,
Kacířová
I
,
Uřinovská
R
,
Šištík
P
,
Grundmann
M
.
New liquid chromatography-tandem mass spectrometry method for routine TDM of vancomycin in patients with both normal and impaired renal functions and comparison with results of polarization fluoroimmunoassay in light of varying creatinine concentrations
.
Clin Chim Acta
.
2017
Jun
;
469
:
136
43
.
[PubMed]
0009-8981
10.
Reeder
JT
,
Choi
J
,
Xue
Y
,
Gutruf
P
,
Hanson
J
,
Liu
M
, et al.
Waterproof, electronics-enabled, epidermal microfluidic devices for sweat collection, biomarker analysis, and thermography in aquatic settings
.
Sci Adv
.
2019
Jan
;
5
(
1
):eaau6356.
[PubMed]
2375-2548
Open Access License / Drug Dosage / Disclaimer
This article is licensed under the Creative Commons Attribution 4.0 International License (CC BY). Usage, derivative works and distribution are permitted provided that proper credit is given to the author and the original publisher.Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug. Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.