This study aimed to evaluate the clinical effect of a resin denture base containing 20wt% surface prereacted glass ionomer (S-PRG) fillers on saliva fluoride concentrations as a surrogate evaluation of caries control. The study was a double-blind randomized clinical trial with a total of 110 participants aged 35–60 years who wore a removable partial resin denture for 1.5 years. Subjects were randomly assigned to receive a partial resin denture fabricated either with or without 20wt% S-PRG fillers (n = 55 per group). After 14 days of wearing the dentures, 5,000 ppm fluoride gel was applied nightly on both sides of the denture before storing it in a denture box overnight every night for 1.5 years. The salivary fluoride concentration was measured at baseline, on days 1, 14, and 15, and at 3 months and 1.5 years of wearing the denture. A significant increase in salivary fluoride concentration in the S-PRG denture group was observed from baseline to day 1, followed by a significant decrease to an approximate baseline level. After recharge with 5,000 ppm fluoride gel, salivary fluoride increased markedly on day 15 and remained elevated at month 3 through to 1.5 years. The resin denture base containing 20wt% S-PRG fillers demonstrated an initial fluoride release that increased saliva fluoride concentrations, but the fluoride release from within the material was short lived. The long-term effect of sustained fluoride release from the denture when combined with a regular fluoride recharge regimen may be beneficial for caries prevention.

1.
Al-Bakri IA, Swain MV, Naoum SJ, Al-Omari WM, Martin E, Ellakwa A: Fluoride release, recharge and flexural properties of polymethylmethacrylate containing fluoridated glass fillers. Aust Dent J 2014; 59: 208–214.
2.
Bergman B, Hugoson A, Olsson CO: A 25 year longitudinal study of patients treated with removable partial dentures. J Oral Rehabil 1995; 22: 595–599.
3.
Bhola R, Bhola SM, Liang H, Mishra B: Biocompatible denture polymers – a review. Trends Biomater Artif Organs 2010; 23: 129–136.
4.
Cunha TR, Regis RR, Bonatti MR, de Souza RF: Influence of incorporation of fluoroal kyl methacrylates on roughness and flexural strength of a denture base acrylic resin. J Appl Oral Sci 2009; 17: 103–107.
5.
Dhondt CL, De Maeyer EA, Verbeeck RM: Fluoride release from glass ionomer activated with fluoride solutions. J Dent Res 2001; 80: 1402–1406.
6.
Dionysopoulosa D: The effect of fluoride-releasing restorative materials on inhibition of secondary caries formation. Fluoride 2014; 47: 258–265.
7.
Duckworth RM, Morgan SN: Oral fluoride retention after use of fluoride dentifrices. Caries Res 1991; 25: 123–129.
8.
Featherstone JD, Singh S, Curtis DA: Caries risk assessment and management for the pros-thodontic patient. J Prosthodont 2011; 20: 2–9.
9.
Fujimoto Y, Iwasa M, Murayama R, Miyazaki M, Nagafuji A, Nakatsuka T: Detection of ions released from S-PRG fillers and their modulation effect. Dent Mater J 2010; 29: 392–397.
10.
Han L, Cv E, Li M, Niwano K, Ab N, Okamoto A, Honda N, Iwaku M: Effect of fluoride mouth rinse on fluoride releasing and recharging from aesthetic dental materials. Dent Mater J 2002; 21: 285–295.
11.
Itota T, Carrick TE, Rusby S, Al-Naimi OT, Yoshiyama M, McCabe JF: Determination of fluoride ions released from resin-based dental materials using ion-selective electrode and ion chromatograph. J Dent 2004a; 32: 117–122.
12.
Itota T, Carrick TE, Yoshiyama M, McCabe JF: Fluoride release and recharge in giomer, compomer and resin composite. Dent Mater J 2004b; 20: 789–795.
13.
Kamijo K, Mukai Y, Tominaga T, Iwaya I, Fujino F, Hirata Y, Teranaka T: Fluoride release and recharge characteristics of denture base resins containing surface pre-reacted glass-ionomer filler. Dent Mater J 2009; 28: 227–233.
14.
McCabe JF, Carrick TE, Sidhu SK: Determining low levels of fluoride released from resin based dental materials. Eur J Oral Sci 2002; 110: 380–384.
15.
Mukai Y, Kamijo K, Fujino F, Hirata Y, Teranaka T, ten Cate JM: Effect of denture base-resin with prereacted glass-ionomer filler on dentin demineralization. Eur J Oral Sci 2009; 117: 750–754.
16.
Najma Hajira NSW, Meena N: GIOMER – the intelligent particle (new generation glass ionomer cement). Int J Dent Oral Health 2015, DOI: 10.16966/23787090.166.
17.
Nakatuka T, Yasuda Y, Kimoto K, Mizuno M, Negoro N: Dental fillers. US Patent Application 6620861 B1. 2003.
18.
Sjogren K, Birkhed D: Factors related to fluoride retention after toothbrushing and possible connection to caries activity. Caries Res 1993; 27: 474–477.
19.
Takada T, Morigami M, Sugizaki S, Uno S, Yamada T: Improvement of giomer composite-SEM observation and clinical application of Beautifil II. Adhes Dent 2007; 25: 19–23.
20.
ten Cate JM: Contemporary perspective on the use of fluoride products in caries prevention. Br Dent J 2013; 214: 161–167.
21.
Toumba KJ, Curzon ME: A clinical trial of a slow-releasing fluoride device in children. Caries Res 2005; 39: 195–200.
22.
Wiegand A, Buchalla W, Attin T: Review on fluoride-releasing restorative materials-fluoride release and uptake characteristics, antibacterial activity and influence on caries formation. Dent Mater J 2007; 23: 343–362.
23.
Zafar MS: Effects of surface pre-reacted glass particles on fluoride release of dental restorative materials. World Appl Sci J 2013; 28: 457–462.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.