Background: Abnormal coronary and brachial artery responses have been described in individuals with risk factors for coronary artery disease (CAD). Peripheral arterial tonometry (PAT), a newly developed digital plethysmographic technique was used to assess peripheral vascular response to exercise in healthy controls and individuals with risk factors. Methods and Results: Continuous finger PAT during Bruce protocol exercise test was performed in 30 subjects with risk factors for CAD and 30 healthy individuals. Compared with baseline, the PAT wave amplitude at peak exercise decreased in the subjects but increased in the controls: 83 ± 28% vs. 114 ± 40% respectively, p < 0.01. Conclusions: A different pattern of systemic vascular response to exercise was found in individuals with risk factors for atherosclerosis. Since the vascular behavior in these patients is probably related to endothelial dysfunction, it may be that peripheral arterial tonometry can be used as a simple, readily available technique to assess endothelial function.

1.
Ross R: The pathogenesis of atherosclerosis: A perspective for the 1990s. Nature 1993;362:801–809.
2.
Ludmer PL, Selwyn AP, Shook TL, Wayne RR, Mudge GH, Alexander RW, Ganz P: Paradoxical vasoconstriction induced by acetylcholine in atherosclerotic coronary arteries. N Engl J Med 1986;315:1046–1051.
3.
Nabel EL, Selwyn AP, Ganz P: Large coronary arteries in humans are responsive to changing blood flow: An endothelium-dependent mechanism that fails in patients with atherosclerosis. J Am Coll Cardiol 1990;16:349–356.
4.
Chowienczyk PJ, Watts GF, Cockcroft JR, Ritter JM: Impaired endothelium-dependent vasodilatation of forearm resistance vessels in hypercholesterolaemia. Lancet 1992;340:1430–1432.
5.
Heitzer T, Yla-Herttuala S, Luoma J, Kurz S, Just H, Olschweski M, Drexler H: Cigarette smoking potentiates endothelial dysfunction of forearm resistance vessels in patients with hypercholesterolemia. Role of oxidized LDL. Circulation 1996;93:1346–1353.
6.
Schächinger V, Zeiher AM: Quantitative assessment of coronary vasoreactivity in humans in vivo. Importance of baseline vasomotor tone in atherosclerosis. Circulation 1995;92:2087–2094.
7.
Clarkson P, Celermajer DS, Donald AE, Sampson M, Sorensen KE, Adams M, Yue DK, Betteridge DJ, Deanfield JE: Impaired vascular reactivity in insulin-dependent diabetes mellitus is related to disease duration and low density lipoprotein cholesterol levels. J Am Coll Cardiol 1996;28:573–579.
8.
Endo T, Imaizumi T, Tagawa T, Shiramoto M, Ando S, Takeshita A: Role of nitric oxide in exercise-induced vasodilation of the forearm. Circulation 1994;90:2886–2990.
9.
Gilligan DM, Panza JA, Kilcoyne CM, Waclawiw MA, Casino PR, Quyyumi AA: Contribution of endothelium-derived nitric oxide to exercise-induced vasodilation. Circulation 1994;90:2853–2858.
10.
Katz SD, Krum H, Khan T, Knecht M: Exercise-induced vasodilation in forearm circulation of normal subjects and patients with congestive heart failure. J Am Coll Cardiol 1966;28:585–590.
11.
Andreassen AK, Kvernebo K, Jorgensen B, Simonsen S, Kjekshus J, Gullestad L: Exercise capacity in heart transplant recipients: Relation to impaired endothelium-dependent vasodilation of the peripheral microcirculation. Am Heart J 1998;136:320–328.
12.
Koller-Strametz SJ, Matulla B, Wolzt M, Miller M, Entlicher J, Eichler HG, Schmetterer L: Role of nitric oxide in exercise-induced vasodilation in man. Life Sci 1998;62.
13.
Indolfi C, Piscione F, Ceravolo R, Maione A, Focaccio A, Rao MA, Esposito G, Condorelli M, Chiariello M: Limb vasoconstriction after successful angioplasty of the left anterior descending coronary artery. Circulation 1995;92:2109–2112.
14.
Chouraqui P, Arditti A, Caspi A, Livschitz S, Scheffy J, Schall RP, Goor DA: Peripheral arterial tonometry: A comparison with stress T1-201 SPECT myocardial imaging for detecting myocardial ischemia (abstract). Circulation (suppl I) 1998;98:I-293.
15.
Vita JA, Treasure CB, Nabel EG, McLenachan JM, Fish RD, Yeung AC, Vekshtein VI, Selwyn AP, Ganz P: Coronary vasomotor response relates to risk factors for coronary artery disease. Circulation 1990;81:491–497.
16.
McAllister RM: Endothelial-mediated control of coronary and skeletal muscle blood flow during exercise: Introduction. Med Sci Sports Exerc 1995;27:1122–1124.
17.
Delp MD, Laughlin MH: Regulation of skeletal muscle perfusion during exercise. Acta Physiol Scand 1998;162:411–419.
18.
Green DJ, O’Driscoll G, Blanksby BA, Taylor RR: Control of muscle blood flow during dynamic exercise: Contribution of endothelium-derived nitric oxide. Sports Med 1996;21:119–146.
19.
Niebauer J, Cooke JP: Cardiovascular effects of exercise: Role of endothelial shear stress. J Am Coll Cardiol 1996;28:1652–1660.
20.
Brett SE, Ritter JM, Chowienczyk PJ: Diastolic blood pressure changes during exercise positively correlate with serum cholesterol and insulin resistance. Circulation 2000;101:611–615.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.