Background: Although there have been reports on threadlike structures inside the heart, they have received little attention. We aimed to develop a method for observing such structures and to reveal their ultrastructures. Methods: An in situ staining method, which uses a series of procedures of 0.2–0.4% trypan blue spraying and washing, was applied to observe threadlike structures on the surfaces of endocardia. The threadlike structures were isolated and observed by using confocal laser scanning microscopy (CLSM) and transmission electron microscopy (TEM). Results: Networks of endocardial vessels (20 µm in thickness) with expansions (40–100 µm in diameter) were visualized; they were movable on the endocardium of the bovine atrium and ventricle. CLSM showed that (1) rod-shaped nuclei were aligned along the longitudinal direction of the endocardial vessel and (2) there were many cells inside the expansion. TEM on the endocardial vessel revealed that (1) there existed multiple lumens (1–7 µm in diameter) and (2) the extracellular matrices mostly consisted of collagen fibers, which were aligned along the longitudinal direction of the endocardial vessel or were locally organized in reticular structures. Conclusion: We investigated the endocardial circulatory system in bovine cardiac chambers and its ultrastructures, such as nucleic distributions, microlumens, and collagenous extracellular matrices.

1.
Kim BH: On the kyungrak system. J Acad Med Sci DPR Kor 1963;90:1–35.
2.
Chan SHH: What is being stimulated in acupuncture: evaluation of the existence of a specific substrate. Neurosci Biobehav Rev 1984;8:25–33.
3.
Fujiwara S: Discovery of Acupuncture Meridians (in Japanese). Osaka, Sogensha, 1967.
4.
Soh KS: Bonghan circulatory system as an extension of acupuncture meridians. J Acupunct Meridian Stud2009;2:93–106.
5.
Lee BC, Park ES, Baik KY, Johng HM, Nam TJ, Lee J, Sung B, Choi C, Yi SH, Park WH, Park DH, Yoon YS, Soh KS: Acridine orange staining method to reveal characteristic features of intravascular threadlike structure. Anat Rec 2004;278B:27–30.
6.
Baik KY, Lee J, Lee BC, Johng HM, Nam TJ, Sung B, Cho S, Soh KS: Acupuncture meridian and intravascular Bonghan duct. Key Eng Mater 2005;277:125–129.
7.
Lee BC, Yoo JS, Baik KY, Sung B, Lee J, Soh KS: Development of a fluorescence stereomicroscope and observation of Bong-Han corpuscles inside blood vessels. Ind J Exp Biol 2008;46:330–335.
8.
Lee BC, Yoo JS, Baik KY, Kim KW, Soh KS: Novel threadlike structures (Bonghan ducts) inside lymphatic vessels of rabbits visualized with a Janus Green B staining method. Anat Rec 2005;286B:1–7.
9.
Johng HM, Yoo JS, Yoon TJ, Shin HS, Lee BC, Lee C, Lee JK, Soh KS: Use of nanoparticles to visualize threadlike structures inside lymphatic vessels of rats. Evid Based Compl Altern Med 2007;4:77–82.
10.
Lee BC, Soh KS: Contrast-enhancing optical method to observe a Bonghan duct floating inside a lymph vessel of a rabbit. Lymphology 2008;41:178–185.
11.
Lee BC, Kim S, Soh KS: Novel anatomic structures in the brain and spinal cord of rabbit that may belong to the Bonghan system of potential acupuncture meridians. J Acupunct Meridian Stud 2008;1:29–35.
12.
Shin HS, Johng HM, Lee BC, Cho SI, Soh KS, Baik KY, Yoo JS, Soh KS: Feulgen reaction study of novel threadlike structures (Bonghan ducts) on the surfaces of mammalian organs. Anat Rec 2005;284B:35–40.
13.
Lee BC, Yoo JS, Ogay V, Kim KW, Dobberstein H, Soh KS, Chang BS: Electron microscopic study of novel threadlike structures on the surfaces of mammalian organs. Microsc Res Tech 2007;70:34–43.
14.
Yoo JS, Kim MS, Sung B, Lee BC, Soh KS, Lee SH, Kim YJ, Dobberstein H: Cribriform structure with channels in the acupuncture meridian-like system on the organ surfaces of rabbits. Acupunct Electrother Res 2007;32:130–132.
15.
Han HJ, Sung B, Ogay V, Soh KS: The flow path of Alcian blue from the acupoint BL23 to the surface of abdominal organs. J Acupunct Meridian Stud 2009;2:182–189.
16.
Yoo JS, Kim HB, Ogay V, Lee BC, Ahn S, Soh KS: Bonghan ducts as possible pathways for cancer metastasis. J Acupunct Meridian Stud 2009;2:118–123.
17.
Ogay V, Bae KH, Kim KW, Soh: Comparison of the characteristic features of Bonghan ducts, blood and lymphatic capillaries. J Acupunct Meridian Stud 2009;2:107–117.
18.
Sung B, Kim MS, Corrigan A, Donald AM, Soh KS: In situ microextraction method to determine the viscosity of biofluid in threadlike structures on the surfaces of mammalian organs. Phys Rev E 2009;79:022901.
19.
Sung B, Kim MS, Lee BC, Yoo JS, Lee SH, Kim YJ, Kim KW, Soh KS: Measurement of flow speed in the channels of novel threadlike structures on the surfaces of mammalian organs. Naturwissenschaften 2008;95:117–124.
20.
Park SH, Lee BC, Choi CJ, Soh KS: Bioelectrical study on Bonghan corpuscles on organ surfaces in rats. J Kor Phys Soc 2009;55:688–693.
21.
Lee BC, Kim KW, Soh KS: Visualizing the network of Bonghan ducts in the omentum and peritoneum by using trypan blue. J Acupunct Meridian Stud 2009;2:66–70.
22.
Sung B, Kim MS, Lee BC, Ahn SH, Hwang SY, Soh KS: A cytological observation of the fluid in the primo-nodes and vessels on the surfaces of mammalian internal organs. Biologia 2010;65:914–918.
23.
Markan S, Haider N, Novalija J, Iqbal Z, Gandhi SD, Pagel PS: A mobile threadlike structure in the left atrium: cor triatriatum, artifact, or thrombus? J Cardiothorac Vasc Anesth 2009;23:566–568.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.