Bilateral macular hole is a rare secondary effect of tamoxifen, a condition which is probably underdiagnosed. We describe the case of a 63-year-old woman who had received low-dose treatment with tamoxifen for 10 years. She presented with a best-corrected visual acuity of 20/40 in both eyes and bilateral macular hole with posterior hyaloid attachment. No reflective deposits were observed. A 23-gauge pars plana vitrectomy with internal limiting membrane peeling and gas tamponade was performed in the right eye with no anatomical or functional improvement. The most accepted mechanism of macular hole related to tamoxifen is Müller cell toxicity with retinal tissue loss. Therefore, it seems that the standard procedure used in idiopathic macular hole is not the optimal choice, due to a different pathogenic mechanism.

Tamoxifen is a non-steroidal selective estrogen receptor modulator used as adjuvant endocrine therapy in estrogen receptor-positive breast cancer. This drug can induce some ocular complications such as crystalline maculopathy, macular edema, retinal vein occlusions, bilateral optic neuritis, and corneal opacities [1]. Recently, some studies have demonstrated that low-dose treatment can be extended up to 10 years, as tamoxifen can reduce relapse of cancer in patients at high risk of recurrence [2]. A relationship between the development of macular hole (MH) and low-dose tamoxifen (usually considered a cumulative dose <100 g) has been recently described [3-8], but the management remains controversial.

A 63-year-old woman with a history of breast cancer presented with mild, progressive, bilateral visual loss for years with no prior ocular history. The patient had received 20 mg of tamoxifen daily for approximately 10 years (cumulative dose around 73 g). She began with this adjuvant therapy following a mastectomy, which had been done rapidly after diagnosis at age 41. Therefore, she had not received tamoxifen for 12 years at presentation. Her best corrected visual acuity was 20/40 in both eyes (BE). Slit lamp examination of the anterior segment was unremarkable. Dilated fundus examination showed an irregular foveal light reflex with pseudohole appearance and no evidence of reflective deposits in the inner layers, which excluded crystalline maculopathy (Fig. 1a, b). Spectral-domain optical coherence tomography (SD-OCT) showed a bilateral MH with a thin overlying roof of inner retinal remnant. Some small cystic spaces on the edges of the hole and attachment of the posterior hyaloid (PH) were also observed with no evidence of thickening or macular edema (Fig. 1c, d). Fluorescein angiography (FA) showed a progressive and diffuse hyperfluorescence in the fovea of BE with no late phase leakage (Fig. 2). FA allows to differentiate retinal changes related to tamoxifen retinopathy, which may be similar on SD-OCT to the ones found in macular telangiectasia type 2 (MacTel2) [9]. Nevertheless, a late leakage of telangiectatic macular capillaries is observed in FA of eyes with MacTel2 [10]. Thus, the diagnosis of bilateral MH related to tamoxifen toxicity was made.

Fig. 1.

a Fundus image of the right eye. b Fundus image of the left eye. An irregular foveal light reflex with a pseudohole appearance is shown in both eyes. c Optical coherence tomography of the right eye before surgery showing full thickness macular hole with some cystic spaces on the edges. The posterior hyaloid is attached and draping of the internal limiting membrane is also observed. d Optical coherence tomography of the left eye showing a foveal cavitation with defect on the outer retinal layers and focal disruption of the photoreceptor layer with sharp edges, which present some cystic spaces. Internal limiting membrane and inner retina bridge are present, and posterior hyaloid is attached.

Fig. 1.

a Fundus image of the right eye. b Fundus image of the left eye. An irregular foveal light reflex with a pseudohole appearance is shown in both eyes. c Optical coherence tomography of the right eye before surgery showing full thickness macular hole with some cystic spaces on the edges. The posterior hyaloid is attached and draping of the internal limiting membrane is also observed. d Optical coherence tomography of the left eye showing a foveal cavitation with defect on the outer retinal layers and focal disruption of the photoreceptor layer with sharp edges, which present some cystic spaces. Internal limiting membrane and inner retina bridge are present, and posterior hyaloid is attached.

Close modal
Fig. 2.

Fluorescein angiography showing a progressive and diffuse hyperfluorescence in the fovea of both eyes with no late phase leakage.

Fig. 2.

Fluorescein angiography showing a progressive and diffuse hyperfluorescence in the fovea of both eyes with no late phase leakage.

Close modal

A 23-gauge pars plana vitrectomy (PPV) with internal limiting membrane (ILM) peeling and sulfur hexafluoride (SF6) 24% gas tamponade was performed in the right eye (RE). The patient rested in prone position for 6 days. The MH remained opened with elevated edges after surgery (Fig. 3). A second 23-gauge PPV was proposed, but the patient rejected it. The patient has been followed for 4 years with no changes in visual acuity (best corrected visual acuity of 20/40 in BE) or SD-OCT images.

Fig. 3.

Optical coherence tomography of the right eye showing full thickness macula hole with thickened retinal edges 3 weeks after surgery.

Fig. 3.

Optical coherence tomography of the right eye showing full thickness macula hole with thickened retinal edges 3 weeks after surgery.

Close modal

The incidence of MH due to tamoxifen toxicity is expected to increase as the tendency is to extend low-dosage tamoxifen treatment. Furthermore, the increasing use of SD-OCT will probably raise the number of cases.Surgical outcome of secondary MH related to tamoxifen toxicity remains unclear. It is worth noticing that in our case BE showed still attached PH, which suggests a different pathomechanism from idiopathic MH, where anteroposterior and tangential traction forces after posterior vitreous detachment are thought to be the main cause of this condition. Therefore, it seems that in this type of secondary MH the standard procedure used in idiopathic MH (i.e., PPV with ILM peeling and gas tamponade) would not be effective, as it seems more related to degenerative mechanisms that lead to tissue loss in the retina. The most accepted mechanism of MH related to tamoxifen is that toxic damage culminates in axonal degeneration leading to Müller cell impairment. It may cause intraretinal foveolar cysts, which in turn would predispose MH formation [11].

Due to the increasing use of SD-OCT and the new trend to extent low-dosage treatment, foveolar cavitations with outer retinal defect and MH related to tamoxifen have been described [4, 5, 7, 8]. In 2005, Gualino et al. [3] first described this complication, and additionally in the same year, Cronin et al. [6] reported a retrospective analysis of 300 consecutive cases of MH and concluded that there was a statistically increased incidence of MH in women treated with tamoxifen.

Concerning the crystalline deposits status in low-dose tamoxifen toxicity, crystalline retinopathy has classically been thought to be the hallmark of tamoxifen toxicity. This association was based on patients treated with high-dose tamoxifen [12]. Superficial crystals have also been observed in patients with early cavitary spaces. Furthermore, more advanced cavitations without visible crystals have been demonstrated in patients who received low-dose tamoxifen [5, 7]. Thus, crystalline maculopathy could represent an earlier finding in tamoxifen toxicity with initial Müller cell damage, while foveal cavitations could correspond to a later stage of atrophy where the crystals have degenerated. Doshi et al. [7] also suggested this possibility after reporting the case of a woman who had received a cumulative dose of tamoxifen of 18.25 mg with evidence of ILM draping with prominent crystals and a small cavitary space in the central fovea on the RE. On the contrary, the left eye of the same patient did not show any visible crystals, although a nearly full thickness cavitation was demonstrated [7]. Therefore, the absence of crystals in the posterior pole might be a common manifestation of late stages of low-dose tamoxifen maculopathy, although more longitudinal follow-up studies are needed to confirm this hypothesis.

Regarding the treatment, Chung et al. [5] reported MH closure and visual improvement in two patients with MH related to systemic antiestrogen agents through surgery with solely 23-gauge PPV and ILM peeling, although crystalline deposits were not found and there was no description about PH membrane status. Even though, Bernstein and DellaCroce [13] also presented the case of a woman who had received tamoxifen with bilateral MH coexisting with crystalline maculopathy who had a previous failed surgery on her RE elsewhere, which was not detailed. A new surgery on her RE with perfluoropropane (C3F8) tamponade successfully closed the MH. Nevertheless, the same surgery was performed on her left eye with no improvement and persistent MH on following examinations [13].

We suggest that observation of MH related to low-dose tamoxifen is a feasible option at this time due to poor functional results after vitrectomy and ILM peeling found in our case and the previous case described by Bernstein and DellaCroce [13]. Nevertheless, more studies are needed in order to understand the evolution of tamoxifen associated with MH, possible precursor lesions, and their optimal management.

Patients with reduced visual acuities may not be aware of their visual deficits initially, as in our case. Macular cavitations and holes due to tamoxifen may occur in the absence of subjective visual complaints. Hence, we strongly recommend – whenever possible – a complete ophthalmologic exam including SD-OCT in those patients under treatment with tamoxifen, regardless of subjective absence of visual impairment.

Finally, if any macular cavitations are observed, a FA should be performed in order to exclude MacTel2. Thus, if any sign of retinal toxicity is detected promptly in those patients under treatment with tamoxifen, progressive visual acuity deterioration could be avoided by considering tamoxifen discontinuation in agreement with the oncologist after considering the risk-benefit profile in each individualized case.

Verbal and written informed consent was obtained from the patient for publication of this case report and all accompanying images.

The authors have no conflict of interest to declare.

Not applicable.

All authors collected and interpreted the patient’s clinical findings. N.T.B. and J.I.V.S. contributed to the writing and editing of the manuscript. N.T.B. reviewed the literature. All authors read and approved the final version of the manuscript.

1.
Ugurlu
S
,
Karagoz
A
,
Altin Ekin
M
.
Ocular findings in breast cancer patients using tamoxifen
.
Cutan Ocul Toxicol
.
2015
Mar
;
34
(
1
):
16
20
.
[PubMed]
1556-9527
2.
Rossi
L
,
McCartney
A
,
De Santo
I
,
Risi
E
,
Moretti
E
,
Malorni
L
, et al.
The optimal duration of adjuvant endocrine therapy in early luminal breast cancer: A concise review
.
Cancer Treat Rev
.
2019
Mar
;
74
:
29
34
.
[PubMed]
0305-7372
3.
Gualino
V
,
Cohen
SY
,
Delyfer
MN
,
Sahel
JA
,
Gaudric
A
.
Optical coherence tomography findings in tamoxifen retinopathy
.
Am J Ophthalmol
.
2005
Oct
;
140
(
4
):
757
8
.
[PubMed]
0002-9394
4.
Hu
Y
,
Liu
N
,
Chen
Y
.
The optical imaging and clinical features of tamoxifen associated macular hole: A case report and review of the literatures
.
Photodiagn Photodyn Ther
.
2017
Mar
;
17
:
35
8
.
[PubMed]
1572-1000
5.
Chung
SE
,
Kim
SW
,
Chung
HW
,
Kang
SW
.
Estrogen antagonist and development of macular hole
.
Korean J Ophthalmol
.
2010
Oct
;
24
(
5
):
306
9
.
[PubMed]
1011-8942
6.
Cronin
BG
,
Lekich
CK
,
Bourke
RD
.
Tamoxifen therapy conveys increased risk of developing a macular hole
.
Int Ophthalmol
.
2005
Jun
;
26
(
3
):
101
5
.
[PubMed]
0165-5701
7.
Doshi
RR
,
Fortun
JA
,
Kim
BT
,
Dubovy
SR
,
Rosenfeld
PJ
.
Pseudocystic foveal cavitation in tamoxifen retinopathy
.
Am J Ophthalmol
.
2014
Jun
;
157
(
6
):
1291
1298.e3
.
[PubMed]
0002-9394
8.
Caramoy
A
,
Scholz
P
,
Fauser
S
,
Kirchhof
B
.
Imaging tamoxifen retinopathy using spectral-domain optical coherence tomography
.
GMS Ophthalmol Cases
.
2011
Dec
;
1
:
Doc07
.
[PubMed]
2193-1496
9.
Lee
S
,
Kim
HA
,
Yoon
YH
.
OCT Angiography Findings of Tamoxifen Retinopathy: Similarity with Macular Telangiectasia Type 2
.
Ophthalmol Retina
.
2019
Aug
;
3
(
8
):
681
9
.
[PubMed]
2468-7219
10.
Behrens
A
,
Sallam
A
,
Pemberton
J
,
Uwaydat
S
.
Tamoxifen use in a patient with idiopathic macular telangiectasia type 2
.
Case Rep Ophthalmol
.
2018
Jan
;
9
(
1
):
54
60
.
[PubMed]
1663-2699
11.
Bringmann
A
,
Pannicke
T
,
Grosche
J
,
Francke
M
,
Wiedemann
P
,
Skatchkov
SN
, et al.
Müller cells in the healthy and diseased retina
.
Prog Retin Eye Res
.
2006
Jul
;
25
(
4
):
397
424
.
[PubMed]
1350-9462
12.
Kovach
JL
,
Isildak
H
,
Sarraf
D
.
Crystalline retinopathy: unifying pathogenic pathways of disease
.
Surv Ophthalmol
.
2019
Jan - Feb
;
64
(
1
):
1
29
.
[PubMed]
0039-6257
13.
Bernstein
PS
,
DellaCroce
JT
.
Diagnostic & therapeutic challenges. Tamoxifen toxicity
.
Retina
.
2007
Sep
;
27
(
7
):
982
8
.
[PubMed]
0275-004X
Open Access License / Drug Dosage / Disclaimer
This article is licensed under the Creative Commons Attribution-NonCommercial 4.0 International License (CC BY-NC). Usage and distribution for commercial purposes requires written permission. Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug. Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.