Introduction: Detecting atrial fibrillation (AF) in patients with embolic stroke of undetermined source (ESUS) is crucial for effective secondary stroke prevention, particularly in those with left atrial enlargement (LAE), as they have a higher risk of subclinical AF. This study aimed to evaluate and compare the efficacy and safety of a patch-type cardiac monitoring device (PCM) in detecting AF in ESUS patients with LAE. Methods: This prospective, multicenter, open-label, randomized, controlled, investigator-initiated trial will recruit a total of 370 ESUS patients with LAE and randomize them in a 1:1 ratio into two groups: the intervention group, which will receive continuous monitoring with the PCM for 1 week, and the control group, which will undergo a single 12-lead electrocardiogram. LAE will be defined as a left atrial diameter greater than 40 mm in males and greater than 38 mm in females or a left atrial volume index exceeding 35. The primary endpoint is the proportion of participants with detected AF. Secondary endpoints include AF burden, detection of other arrhythmias, and the incidence of tachycardia, bradycardia, premature atrial contractions, and atrial flutter. A post hoc analysis will explore factors influencing AF detection and aim to develop a predictive model based on clinical and imaging data. Conclusion: This trial is expected to provide valuable insights into the safety and efficacy of PCM in detecting AF, potentially influencing clinical strategies for AF detection and management in ESUS patients with LAE.

1.
Miyazaki
Y
,
Toyoda
K
,
Iguchi
Y
,
Hirano
T
,
Metoki
N
,
Tomoda
M
, et al
.
Atrial fibrillation after ischemic stroke detected by chest strap-style 7-day holter monitoring and the risk predictors: educate-esus
.
J Atheroscler Thromb
.
2021
;
28
(
5
):
544
54
.
2.
Hart
RG
,
Sharma
M
,
Mundl
H
,
Kasner
,
SE
,
Bangdiwala
,
SI
,
Berkowitz
,
SD
, et al
.
Rivaroxaban for stroke prevention after embolic stroke of undetermined source
.
N Engl J Med
.
2018
;
378
(
23
):
2191
201
.
3.
Chousou
PA
,
Chattopadhyay
R
,
Ring
L
,
Khadjooi
K
,
Warburton
EA
,
Mukherjee
T
, et al
.
Atrial fibrillation in embolic stroke of undetermined source: role of advanced imaging of left atrial function
.
Eur J Prev Cardiol
.
2023
;
30
(
18
):
1965
74
.
4.
Diener
H-C
,
Sacco
RL
,
Easton
JD
,
Granger
CB
,
Bernstein
RA
,
Uchiyama
S
, et al
.
Dabigatran for prevention of stroke after embolic stroke of undetermined source
.
N Engl J Med
.
2019
;
380
(
20
):
1906
17
.
5.
Melis
F
,
Guido
M
,
Amellone
C
,
Suppo
M
,
Bonanno
M
,
Bovio
C
, et al
.
Prevalence and predictors of atrial fibrillation in patients with embolic stroke of undetermined source: a real-life single-center retrospective study
.
Neurol Sci
.
2021
;
42
(
9
):
3707
14
.
6.
Ramos-Maqueda
J
,
Navarro-Valverde
C
,
Esteve-Ruiz
I
,
Cabrera-Ramos
M
,
Rivera-López
R
,
García-Medina
D
, et al
.
Atrial fibrillation predictors in patients with embolic stroke of undetermined source
.
Med Clin
.
2021
;
157
(
12
):
555
60
. Predictores de fibrilación auricular en pacientes con ictus embólico de origen indeterminado.
7.
Hashimoto
K
,
Harada
N
,
Kasamaki
Y
.
Can a patch electrocardiographic device Be a leading actor for detecting atrial fibrillation? diversifying electrocardiographic monitoring devices
.
Circ J
.
2022
;
86
(
2
):
189
91
.
8.
Sanna
T
,
Diener
H-C
,
Passman
RS
,
Di Lazzaro
V
,
Bernstein
RA
,
Morillo
CA
, et al
.
Cryptogenic stroke and underlying atrial fibrillation
.
N Engl J Med
.
2014
;
370
(
26
):
2478
86
.
9.
Noseworthy
PA
,
Kaufman
ES
,
Chen
LY
,
Chung
MK
,
Elkind
MSV
,
Joglar
JA
, et al
.
Subclinical and device-detected atrial fibrillation: pondering the knowledge gap: a scientific statement from the American heart association
.
Circulation
.
2019
;
140
(
25
):
e944
63
.
10.
Eysenck
W
,
Freemantle
N
,
Sulke
N
.
A randomized trial evaluating the accuracy of AF detection by four external ambulatory ECG monitors compared to permanent pacemaker AF detection
.
J Interv Card Electrophysiol
.
2020
;
57
(
3
):
361
9
.
11.
Rosenberg
MA
,
Samuel
M
,
Thosani
A
,
Zimetbaum
PJ
.
Use of a noninvasive continuous monitoring device in the management of atrial fibrillation: a pilot study
.
Pacing Clin Electrophysiol
.
2013
;
36
(
3
):
328
33
.
12.
Perez
MV
,
Mahaffey
KW
,
Hedlin
H
,
Rumsfeld
,
JS
,
Garcia
,
A
,
Ferris
,
T
, et al
.
Large-scale assessment of a smartwatch to identify atrial fibrillation
.
N Engl J Med
.
2019
;
381
(
20
):
1909
17
.
13.
Halcox
JPJ
,
Wareham
K
,
Cardew
A
,
Gilmore
M
,
Barry
JP
,
Phillips
C
, et al
.
Assessment of remote heart rhythm sampling using the AliveCor heart monitor to screen for atrial fibrillation: the REHEARSE-AF study
.
Circulation
.
2017
;
136
(
19
):
1784
94
.
14.
Gladstone
DJ
,
Wachter
R
,
Schmalstieg-Bahr
K
,
Quinn
FR
,
Hummers
E
,
Ivers
N
, et al
.
Screening for atrial fibrillation in the older population: a randomized clinical trial
.
JAMA Cardiol
.
2021
;
6
(
5
):
558
67
.
15.
Kleindorfer
DO
,
Towfighi
A
,
Chaturvedi
S
,
Cockroft
,
KM
,
Gutierrez
,
J
,
Lombardi-Hill
,
D
, et al
.
2021 guideline for the prevention of stroke in patients with stroke and transient ischemic attack: a guideline from the American heart association/American stroke association
.
Stroke
.
2021
;
52
(
7
):
e364
467
.
16.
Rodrigues
J
,
Erdei
T
,
McIntyre
B
,
Dastidar
AG
,
Burchell
AE
,
Ratcliffe
LE
, et al
.
Electrocardiographic detection of left atrial enlargement in arterial hypertension: Re-calibration against cardiac magnetic resonance
.
J Cardiovasc Magn Reson
.
2016
;
18
:
Q26
.
17.
Higgins
CB
,
Reinke
RT
,
Jones
NE
,
Broderick
T
.
Left atrial dimension on the frontal thoracic radiograph: a method for assessing left atrial enlargement
.
AJR Am J Roentgenol
.
1978
;
130
(
2
):
251
5
.
18.
Bae
JH
,
Ryu
JC
,
Ha
SH
,
Cho
MS
,
Cha
MJ
,
Chang
JY
, et al
.
Factors associated with the detection of atrial fibrillation in patients with embolic stroke of undetermined source
.
BMC Neurol
.
2025
;
25
(
1
):
15
.
19.
Lumikari
TJ
,
Putaala
J
,
Kerola
A
,
Sibolt
G
,
Pirinen
J
,
Pakarinen
S
, et al
.
Continuous 4-week ECG monitoring with adhesive electrodes reveals AF in patients with recent embolic stroke of undetermined source
.
Ann Noninvasive Electrocardiol
.
2019
;
24
(
5
):
e12649
.
20.
Rubio Campal
JM
,
García Torres
MA
,
Sánchez Borque
P
,
Navas Vinagre
I
,
Zamarbide Capdepón
I
,
Miracle Blanco
Á
, et al
.
Detecting atrial fibrillation in patients with an embolic stroke of undetermined source (from the DAF-ESUS registry)
.
Am J Cardiol
.
2020
;
125
(
3
):
409
14
.
21.
McGrath
ER
,
Kapral
MK
,
Fang
J
,
Eikelboom
JW
,
Conghaile
A
,
Canavan
M
, et al
.
Association of atrial fibrillation with mortality and disability after ischemic stroke
.
Neurology
.
2013
;
81
(
9
):
825
32
.
22.
Lattanzi
S
,
Rinaldi
C
,
Pulcini
A
,
Corradetti
T
,
Angelocola
S
,
Zedde
ML
, et al
.
Clinical phenotypes of embolic strokes of undetermined source
.
Neurol Sci
.
2021
;
42
(
1
):
297
300
.
23.
Sanna
T
,
Ziegler
PD
,
Crea
F
.
Detection and management of atrial fibrillation after cryptogenic stroke or embolic stroke of undetermined source
.
Clin Cardiol
.
2018
;
41
(
3
):
426
32
.
24.
Lee
JH
,
Moon
IT
,
Cho
Y
,
Kim
JY
,
Kang
J
,
Kim
BJ
, et al
.
Left atrial diameter and atrial ectopic burden in patients with embolic stroke of undetermined source: risk stratification of atrial fibrillation with insertable cardiac monitor analysis
.
J Clin Neurol
.
2021
;
17
(
2
):
213
9
.
25.
Lee
MH
,
Koo
J
,
Kwon
H
,
Chang
JY
,
Kang
DW
,
Kwon
SU
, et al
.
Early apixaban administration considering the size of infarction and functional outcome in acute ischemic stroke
.
Front Neurol
.
2024
;
15
:
1302738
.
26.
Sposato
LA
,
Riccio
PM
,
Hachinski
V
.
Poststroke atrial fibrillation: cause or consequence? Critical review of current views
.
Neurology
.
2014
;
82
(
13
):
1180
6
.
27.
Kim
AS
,
Kamel
H
,
Bernstein
RA
,
Manchanda
M
,
Caprio
FZ
.
Controversies in stroke: should patients with embolic stroke of undetermined source undergo intensive heart rhythm monitoring with an implantable loop recorder
.
Stroke
.
2022
;
53
(
10
):
3243
7
.
28.
Ryu
JC
,
Lee
SH
,
Jung
JM
,
Kwon
B
,
Song
Y
,
Lee
DH
, et al
.
Association between the timing of atrial fibrillation detection and functional outcome following mechanical thrombectomy
.
J Am Heart Assoc
.
2024
;
13
(
17
):
e034861
.
29.
Kamel
H
,
Longstreth
WT
,
Tirschwell
DL
,
Kronmal
RA
,
Marshall
RS
,
Broderick
JP
, et al
.
Apixaban to prevent recurrence after cryptogenic stroke in patients with atrial cardiopathy: the ARCADIA randomized clinical trial
.
JAMA
.
2024
;
331
(
7
):
573
81
.
30.
Kato
Y
,
Takahashi
S
.
Atrial cardiopathy and cryptogenic stroke
.
Front Neurol
.
2022
;
13
:
839398
.
You do not currently have access to this content.