Introduction: Expediting notification of lesions in acute ischemic stroke (AIS) is critical. Limited availability of experts to assess such lesions and delays in large vessel occlusion (LVO) recognition can negatively affect outcomes. Artificial intelligence (AI) may aid LVO recognition and treatment. This study aims to evaluate the performance of an AI-based algorithm for LVO detection in AIS. Methods: Retrospective analysis of a database of AIS patients admitted in a single center between 2014 and 2019. Vascular neurologists graded computed tomography angiographies (CTAs) for presence and site of LVO. Studies were analyzed by the Viz-LVO Algorithm® version 1.4 – neural network programmed to detect occlusions from the internal carotid artery terminus (ICA-T) to the Sylvian fissure. Comparisons between human versus AI-based readings were done by test characteristic analysis and Cohen’s kappa. Primary analysis included ICA-T and/or middle cerebral artery (MCA)-M1 LVOs versus non-LVOs/more distal occlusions. Secondary analysis included MCA-M2 occlusions. Results: 610 CTAs were analyzed. The AI algorithm rejected 2.5% of the CTAs due to poor quality, which were excluded from the analysis. Viz-LVO identified ICA-T and MCA-M1 LVOs with a sensitivity of 87.6%, specificity of 88.5%, and accuracy of 87.9% (AUC 0.88, 95% CI: 0.85–0.92, p < 0.001). Cohen’s kappa was 0.74. In the secondary analysis, the algorithm yielded a sensitivity of 80.3%, specificity of 88.5%, and accuracy of 82.7%. The mean run time of the algorithm was 2.78 ± 0.5 min. Conclusion: Automated AI reading allows for fast and accurate identification of LVO strokes with timely notification to emergency teams, enabling quick decision-making for reperfusion therapies or transfer to specialized centers if needed.

1.
Katan
M
,
Luft
A
.
Global burden of stroke
.
Semin Neurol
.
2018
;
38
(
2
):
208
11
. .
2.
Malhotra
K
,
Gornbein
J
,
Saver
JL
.
Ischemic strokes due to large-vessel occlusions contribute disproportionately to stroke-related dependence and death: a review
.
Front Neurol
.
2017
;
8
:
651
. .
3.
Goyal
M
,
Menon
BK
,
van Zwam
WH
,
Dippel
DW
,
Mitchell
PJ
,
Demchuk
AM
,
Endovascular thrombectomy after large-vessel ischaemic stroke: a meta-analysis of individual patient data from five randomised trials
.
Lancet
.
2016
;
387
(
10029
):
1723
31
. .
4.
Hacke
W
,
Lyden
P
,
Emberson
J
,
Baigent
C
,
Blackwell
L
,
Albers
G
,
Effects of alteplase for acute stroke according to criteria defining the European Union and United States marketing authorizations: individual-patient-data meta-analysis of randomized trials
.
Int J Stroke
.
2018
;
13
(
2
):
175
89
. .
5.
Kamal
N
,
Sheng
S
,
Xian
Y
,
Matsouaka
R
,
Hill
MD
,
Bhatt
DL
,
Delays in door-to-needle times and their impact on treatment time and outcomes in get with the guidelines-stroke
.
Stroke
.
2017
;
48
(
4
):
946
54
. .
6.
Jiang
F
,
Jiang
Y
,
Zhi
H
,
Dong
Y
,
Li
H
,
Ma
S
,
Artificial intelligence in healthcare: past, present and future
.
Stroke Vasc Neurol
.
2017
;
2
(
4
):
230
43
. .
7.
Feng
R
,
Badgeley
M
,
Mocco
J
,
Oermann
EK
.
Deep learning guided stroke management: a review of clinical applications
.
J Neurointerv Surg
.
2018
;
10
(
4
):
358
62
. .
8.
Çiçek
Ö
,
Abdulkadir
A
,
Lienkamp
SS
,
Brox
T
,
Ronneberger
O
.
3D U-net: learning dense volumetric segmentation from sparse annotation
.
arXiv
.
2016 Jun 1
. [arXiv:1606.06650 p.]. Available from: https://ui.adsabs.harvard.edu/abs/2016arXiv160606650C.
9.
Ronneberger
O
,
Fischer
P
,
Brox
T
.
U-Net: convolutional networks for biomedical image segmentation
.
arXiv
.
2015 May 1
. [arXiv:1505.04597 p.]. Available from: https://ui.adsabs.harvard.edu/abs/2015arXiv150504597R.
10.
Murray
NM
,
Unberath
M
,
Hager
GD
,
Hui
FK
.
Artificial intelligence to diagnose ischemic stroke and identify large vessel occlusions: a systematic review
.
J Neurointerv Surg
.
2020
;
12
(
2
):
156
64
. .
11.
Sheth
SA
,
Lopez-Rivera
V
,
Barman
A
,
Grotta
JC
,
Yoo
AJ
,
Lee
S
,
Machine learning-enabled automated determination of acute ischemic core from computed tomography angiography
.
Stroke
.
2019
;
50
(
11
):
3093
100
. .
12.
Amukotuwa
SA
,
Straka
M
,
Smith
H
,
Chandra
RV
,
Dehkharghani
S
,
Fischbein
NJ
,
Automated detection of intracranial large vessel occlusions on computed tomography angiography: a single center experience
.
Stroke
.
2019
;
50
(
10
):
2790
8
. .
13.
Amukotuwa
SA
,
Straka
M
,
Dehkharghani
S
,
Bammer
R
.
Fast automatic detection of large vessel occlusions on CT angiography
.
Stroke
.
2019
;
50
(
12
):
3431
8
. .
14.
Mazighi
M
,
Derex
L
,
Amarenco
P
.
Prehospital stroke care: potential, pitfalls, and future
.
Curr Opin Neurol
.
2010
;
23
(
1
):
31
5
. .
15.
Kwan
J
,
Hand
P
,
Sandercock
P
.
Improving the efficiency of delivery of thrombolysis for acute stroke: a systematic review
.
QJM
.
2004
;
97
(
5
):
273
9
. .
16.
Nogueira
RG
,
Ribo
M
.
Endovascular treatment of acute stroke
.
Stroke
.
2019
;
50
(
9
):
2612
8
.
17.
Eng
MS
,
Patel
AV
,
Libman
RB
,
Wright
P
,
Katz
JM
.
Improving regional stroke systems of care
.
Curr Atheroscler Rep
.
2017
;
19
(
12
):
52
. .
18.
Saver
JL
,
Goyal
M
,
van der Lugt
A
,
Menon
BK
,
Majoie
CB
,
Dippel
DW
,
Time to treatment with endovascular thrombectomy and outcomes from ischemic stroke: a meta-analysis
.
JAMA
.
2016
;
316
(
12
):
1279
88
. .
19.
Hinman
JD
,
Rost
NS
,
Leung
TW
,
Montaner
J
,
Muir
KW
,
Brown
S
,
Principles of precision medicine in stroke
.
J Neurol Neurosurg Psychiatry
.
2017
;
88
(
1
):
54
61
. .
20.
Lee
EJ
,
Kim
YH
,
Kim
N
,
Kang
DW
.
Deep into the brain: artificial intelligence in stroke imaging
.
J Stroke
.
2017
;
19
(
3
):
277
85
. .
21.
Arbabshirani
MR
,
Fornwalt
BK
,
Mongelluzzo
GJ
,
Suever
JD
,
Geise
BD
,
Patel
AA
,
Advanced machine learning in action: identification of intracranial hemorrhage on computed tomography scans of the head with clinical workflow integration
.
NPJ Digit Med
.
2018
;
1
(
1
):
9
. .
22.
Herweh
C
,
Ringleb
PA
,
Rauch
G
,
Gerry
S
,
Behrens
L
,
Möhlenbruch
M
,
Performance of e-ASPECTS software in comparison to that of stroke physicians on assessing CT scans of acute ischemic stroke patients
.
Int J Stroke
.
2016
;
11
(
4
):
438
45
. .
23.
Nagel
S
,
Sinha
D
,
Day
D
,
Reith
W
,
Chapot
R
,
Papanagiotou
P
,
e-ASPECTS software is non-inferior to neuroradiologists in applying the ASPECT score to computed tomography scans of acute ischemic stroke patients
.
Int J Stroke
.
2017
;
12
(
6
):
615
22
. .
24.
Nogueira
RG
,
Lutsep
HL
,
Gupta
R
,
Jovin
TG
,
Albers
GW
,
Walker
GA
,
Trevo versus Merci retrievers for thrombectomy revascularisation of large vessel occlusions in acute ischaemic stroke (TREVO 2): a randomised trial
.
Lancet
.
2012
;
380
(
9849
):
1231
40
. .
25.
Binning
MJ
,
Bartolini
B
,
Baxter
B
,
Budzik
R
,
English
J
,
Gupta
R
,
Trevo 2000: results of a large real-world registry for stent retriever for acute ischemic stroke
.
J Am Heart Assoc
.
2018
;
7
(
24
):
e010867
. .
26.
Mueller-Kronast
NH
,
Zaidat
OO
,
Froehler
MT
,
Jahan
R
,
Aziz-Sultan
MA
,
Klucznik
RP
,
Systematic evaluation of patients treated with neurothrombectomy devices for acute ischemic stroke: primary results of the STRATIS registry
.
Stroke
.
2017
;
48
(
10
):
2760
8
. .
27.
Menon
BK
,
Hill
MD
,
Davalos
A
,
Roos
Y
,
Campbell
BCV
,
Dippel
DWJ
,
Efficacy of endovascular thrombectomy in patients with M2 segment middle cerebral artery occlusions: meta-analysis of data from the HERMES Collaboration
.
J Neurointerv Surg
.
2019
;
11
(
11
):
1065
9
.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.