We prospectively evaluated 30 consecutive patients with echo-enhanced transcranial color-coded duplexsonography (TCCD) and correlative transfemoral digital subtraction angiography to assess the diagnostic efficacy of echo-enhanced TCCD for evaluation of collateral pathways through the circle of Willis in patients with limited acoustic bone windows and critical symptomatic carotid disease. Echo-enhanced TCCD detected collateral blood flow through the anterior communicating artery in 16 of 18 patients (sensitivity 89%, 95% CI 65–99%) and was false positive in one out of 12 patients without collateral flow (specificity 92%, 95% CI 59–100%). For the posterior communicating artery, sensitivity was 11/14 (79%, 95% CI 49–95%) and specificity was 15/16 (94%, 95% CI 70–100%). Echo-enhanced TCCD enables to study collateral blood flow through the communicating arteries of the circle of Willis with high sensitivity and specificity in patients with obstructions of the internal carotid artery and limited acoustic bone windows.

1.
Mohr JP, Gautier JC, Pessin MS: Internal carotid artery disease; in Barnett HJ, Mohr JP, Stein BM, Yatsu FM (eds): Stroke: Pathophysiology, Diagnosis, and Management, ed 3. New York, Churchill Livingstone, 1998, pp 355–400.
2.
Battacharij SK, Hutchinson EC, McCall AJ: The Circle of Willis – The incidence of developmental abnormalities in normal and infarcted brains. Brain 1967;90:747–758.
3.
Schneider PA, Ringelstein EB, Rossman ME, Dilley RB, Sobel DF, Otis SM, Bernstein EF: Importance of cerebral collateral pathways during carotid endarterectomy. Stroke 1988;19:1328–1334.
4.
Lindegaard KF, Bakke SJ, Grolimund P, Aaslid R, Huber P, Nornes H: Assessment of intracranial hemodynamics in carotid artery disease by transcranial Doppler ultrasound. J Neurosurg 1985;63:890–898.
5.
Muller M, Hermes M, Bruckmann H, Schimrigk K: Transcranial Doppler ultrasound in the evaluation of collateral blood flow in patients with internal carotid artery occlusion: Correlation with cerebral angiography. Am J Neuroradiol 1995;16:195–202.
6.
Bogdahn U, Becker G, Schlief R, Reddig J, Hassel W: Contrast-enhanced transcranial color-coded real-time sonography. Results of a phase-two study. Stroke 1993;24:676–684.
7.
Martin PJ, Smith JL, Gaunt ME, Naylor AR: Assessment of intracranial primary collaterals using transcranial color-coded real-time sonography (see comments). J Neuroimaging 1995;5:199–205.
8.
Baumgartner RW, Baumgartner I, Mattle HP, Schroth G: Transcranial color-coded duplex sonography in the evaluation of collateral flow through the circle of Willis. Am J Neuroradiol 1997;18:127–133.
9.
Itoh T, Matsumoto M, Handa N, Maeda H, Hougaku H, Hashimoto H, Etani H, Tsukamoto Y, Kamada T: Rate of successful recording of blood flow signals in the middle cerebral artery using transcranial Doppler sonography. Stroke 1993;24:1192–1195.
10.
Seidel G, Kaps M, Gerriets T: Potential and limitations of transcranial color-coded sonography in stroke patients. Stroke 1995;26:2061–2066.
11.
Gahn G, Gerber J, Hallmeyer S, Reichmann H, von Kummer R: Noninvasive assessment of the circle of Willis in cerebral ischemia: The potential of CT angiography and contrast-enhanced transcranial color-coded duplexsonography. Cerebrovasc Dis 1999;9:290–294.
12.
Nabavi DG, Droste DW, Schulte-Altedorneburg G, Kemeny V, Panzica M, Weber S, Ringelstein EB: Diagnostic benefit of echocontrast enhancement for the insufficient transtemporal bone window. J Neuroimaging 1999;9:102–107.
13.
Postert T, Federlein J, Przuntek H, Buttner T: Insufficient and absent acoustic temporal bone window: Potential and limitations of transcranial contrast-enhanced color-coded sonography and contrast-enhanced power-based sonography. Ultrasound Med Biol 1997;23:857–862.
14.
Gerriets T, Seidel G, Fiss I, Modrau B, Kaps M: Contrast-enhanced transcranial color-coded duplex sonography: Efficiency and validity. Neurology 1999;52:1133–1137.
15.
Ackerman RH, Candia MR: Identifying clinically relevant carotid disease. Stroke 1994;25:1–3.
16.
Bogdahn U, Becker G, Winkler J, Greiner K, Perez J, Meurers B: Transcranial color-coded real-time sonography in adults. Stroke 1990;21:1680–1688.
17.
Forsberg F, Liu JB, Burns PN, Merton DA, Goldberg BB: Artifacts in ultrasonic contrast agent studies. J Ultrasound Med 1994;13:357–365.
18.
Albrecht T, Urbank A, Mahler M, Bauer A, Dore CJ, Blomley MJ, Cosgrove DO, Schlief R: Prolongation and optimization of Doppler enhancement with a microbubble US contrast agent by using continuous infusion: Preliminary experience. Radiology 1998;207:339–347.
19.
Gahn G, Gerber J, Hallmeyer S, et al: Contrast-enhanced transcranial color coded duplexsonography in stroke patients with limited bone windows. Am J Neuroradiol 2000;21:509–514.
20.
Willeit J, Kiechl S: Prevalence and risk factors of asymptomatic extracranial carotid artery atherosclerosis. A population-based study. Arterioscler Thromb 1993;13:661–668.
21.
van Everdingen KJ, Visser GH, Klijn CJ, Kappelle LJ, van der Grond XY: Role of collateral flow on cerebral hemodynamics in patients with unilateral internal carotid artery occlusion. Ann Neurol 1998;44:167–176.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.