An international Consensus Meeting to determine a standard in the examination technique for the detection of right-to-left shunt (RLS) using contrast transcranial Doppler sonography (TCD) led to the following recommendations to standardize the examination procedure: The patient should be prepared with an 18-gauge needle inserted into the cubital vein and should be in the supine position. Insonation of at least one middle cerebral artery (MCA) using TCD is performed. The contrast agent is prepared using 9 ml isotonic saline solution and 1 ml air mixed with a three-way stopcock by exchange of saline/air mixture between the syringes and injected as a bolus. In case of little or no detection of microbubbles (MB) in the MCA under basal conditions, the examination will be repeated using the Valsalva maneuver (VM). Contrast agent will be injected 5 s before the start of the VM; the overall VM duration should be 10 s. The patient should start the VM on examiner’s command. The strength of the VM can be controlled by peak flow velocity of the Doppler curve. The time when the first MB appears at the MCA level will be noted. A four-level categorization according to the MB count should be applied: (1) 0 MB (negative result); (2) 1–10 MB; (3) >10 MB and no curtain, and (4) curtain. (‘Curtain’ refers to a shower of MB, where a single bubble cannot be identified.) The results should be documented for basal condition and VM testing separately. The clinical significance of the diagnosis of a RLS in a particular patient is not fully evaluated and requires further studies. A minimum amount of MB suggestive of a clinical relevant RLS is not yet established. It probably depends on interindividual differences in hemodynamics that are currently not fully understood. Transesophageal echocardiography remains the gold standard for detection of a patent foramen ovale or an atrial septum defect. However, TCD with a contrast agent has been turned out as a potential method to diagnose a RLS in several studies which have been published during the last years, and a RLS other than at the atrial level may be detected only by this method. Furthermore, the VM can be applied more comfortably and more reliably during Doppler examination than during transesophageal echocardiography.

1.
Glaser EM: Using behavioral science strategies for defining the state-of-the-art. J Appl Behav Sci 1980;16:79–92.
2.
Fink A, Kosecoff J, Chassin M, Brook RH: Consensus methods. Characteristics and guidelines for use. Am J Public Health 1984;74:979–983.
3.
Dudley DL, Glaser EM, Jorgenson BN, Logan DL: Psychosocial concomitants to rehabilitation in chronic obstructive pulmonary disease. I. Psychosocial and psychological considerations. Chest 1980;77:413–420.
4.
Lechat P, Mas JL, Lascault G, Loron P, Theard M, Klimczac M, Drobinski G, Thomas D, Grosgogeat Y: Prevalence of patent foramen ovale in patients with stroke. N Engl J Med 1988;318:1148–1152.
5.
Schwarze JJ, Sander D, Kukla C, Wittich I, Babikian V, Klingelhöfer J: Methodological parameters influence the detection of right-to-left shunts by contrast transcranial Doppler. Stroke 1999;30:1234–1239.
6.
Zanette EM, Mancini G, De Castro S, Solaro M, Cartoni D, Chiarotti F: Patent foramen ovale and transcranial Doppler: Comparison of different procedures. Stroke 1996;27:2251–2255.
7.
Schminke U, Ries S, Daffertshofer M, Staedt U, Hennerici M: Patent foramen ovale: A potential source of cerebral embolism. Cerebrovasc Dis 1995;5:133–138.
8.
Steiner MM, Di Tullio MR, Rundek T, Gan R, Chen X, Liguori C, Brainin M, Homma S, Sacco RL: Patent foramen ovale size and embolic brain imaging findings among patients with ischemic stroke. Stroke 1998;29:944–948.
9.
Serena J, Segura T, Perez-Ayuso MJ, Bassaganyas J, Molins A, Davalos A: The need to quantify right-to-left shunt in acute ischemic stroke: A case-control study. Stroke 1998;29:1322–1328.
10.
Homma S, Di Tullio MR, Sacco RL, Mihalatos D, Li Mandri G, Mohr JP: Characteristics of patent foramen ovale associated with cryptogenic stroke: A biplane transesophageal echocardiographic study. Stroke 1994;25:582–586.
11.
Job FP, Ringelstein EB, Grafen Y, Flachskampf FA, Doherty C, Stockmanns A, Hanrath P: Comparison of transcranial contrast Doppler sonography and transesophageal contrast echocardiography for the detection of patent foramen ovale in young stroke patients. Am J Cardiol 1994;74:381–384.
12.
Jauss M, Kaps M, Keberle M, Haberbosch W, Dorndorf W: A comparison of transesophageal echocardiography and transcranial Doppler sonography with contrast medium for detection of patent foramen ovale. Stroke 1994;25:1265–1267.
13.
Devuyst G, Despland PA, Bogousslavsky J, Jeanrenaud X: Complementarity of contrast transcranial Doppler and contrast transesophageal echocardiography for the detection of patent foramen ovale in stroke patients. Eur Neurol 1997;38:21–25.
14.
Anzola GP, Renaldini E, Magoni M, Costa A, Cobelli M, Guindani M. Validation of transcranial Doppler sonography in the assessment of patent foramen ovale. Cerebrovasc Dis 1995;5:194–198.
15.
Droste DW, Reisener M, Kemeny V, Dittrich R, Schulte-Altedorneburg G, Stypmann J, Widimsky P, Wichter T, Ringelstein EB: Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts: Reproducibility, comparison of two agents, and distribution of microemboli. Stroke 1999;30:1014–1018.
16.
Droste DW, Kriete JU, Stypmann J, Castrucci M, Wichter T, Tietje R, Weltermann B, Young P, Ringelstein EB: Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts: Comparison of different procedures and different contrast agents. Stroke 1999;30:1827–1832.
17.
Schlief R, Schurman R, Niendorf HP: Basic properties and results of clinical trials of ultrasound contrast agents based on galactose. Ann Acad Med Singapore 1993;22:762–767.
18.
Schwarze JJ, Klingelhöfer J, Sander D, Kukla C, Wittich I: Factors influencing the sensitivity of contrast-TCD method in the detection of right-to-left shunts; in Klingelhöfer J, Bartels E, Ringelstein E (eds): New Trends in Cerebral Hemodynamics and Neurosonology. Amsterdam, Elsevier, 1997, pp 475–482.
19.
Khan KA, Yeung M, Shuaib A: Comparative study of 18 gauge and 20 gauge intravenous catheters during transcranial Doppler ultrasonography with saline solution contrast. J Ultrasound Med 1997;16:341–344.
20.
Yeung M, Khan KA, Shuaib A: Transcranial Doppler ultrasonography in the detection of venous to arterial shunting in acute stroke and transient ischaemic attacks. J Neurol Neurosurg Psychiatry 1996;61:445–449.
21.
Klötzsch C, Janssen G, Berlit P: Transesophageal echocardiography and contrast-TCD in the detection of a patent foramen ovale: Experiences with 111 patients. Neurology 1994;44:1603–1606.
22.
Horner S, Ni XS, Weihs W, Harb S, Augustin M, Duft M, Niederkorn K: Simultaneous bilateral contrast transcranial Doppler monitoring in patients with intracardiac and intrapulmonary shunts. J Neurol Sci 1997;150:49–57.
23.
Hamann GF, Schätzer-Klotz D, Fröhlig G, Strittmatter M, Jost V, Berg G, Stopp M, Schimrigk K, Schieffer H: Femoral injection of echo contrast medium may increase the sensitivity of testing for a patent foramen ovale. Neurology 1998;50:1423–1428.
24.
Teague SM, Sharma MK: Detection of paradoxical cerebral echo contrast embolization by transcranial Doppler ultrasound. Stroke 1991;22:740–745.
25.
Di Tullio M, Sacco RL, Venketasubramanian N, Sherman D, Mohr JP, Homma S: Comparison of diagnostic techniques for the detection of a patent foramen ovale in stroke patients. Stroke 1993;24:1020–1024.
26.
Klingelhöfer J, Schwarze JJ, Sander D, Kukla C, Wittich I: Distribution of ultrasonic medium predicts the territory of cerebral infarction; in Klingelhöfer J, Bartels E, Ringelstein E (eds): New Trends in Cerebral Hemodynamics and Neurosonology. Amsterdam, Elsevier, 1997, pp 494–499.
27.
Nemec JJ, Marwick TH, Lorig RJ, Davison MB, Chimowitz MI, Litowitz H, Salcedo EE: Comparison of transcranial Doppler ultrasound and transesophageal contrast echocardiography in the detection of interatrial right-to-left shunts. Am J Cardiol 1991;68:1498–1502.
28.
Karnik R, Stollberger C, Valentin A, Winkler WB, Slany J: Detection of patent foramen ovale by transcranial contrast Doppler ultrasound. Am J Cardiol 1992;69:560–562.
29.
Chimowitz MI, Nemec JJ, Marwick TH, Lorig RJ, Furlan AJ, Salcedo EE: Transcranial Doppler ultrasound identifies patients with right-to-left cardiac or pulmonary shunts. Neurology 1991;41:1902–1904.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.