1-20 of 24
Keywords: Anticoagulation
Close
Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Journal Articles
Journal Articles
Blood Purif (2023) 52 (Suppl. 1): 95–97.
Published Online: 16 June 2023
... that, if necessary, a reduction in anticoagulation may be possible when dialysis is performed with the Toray Filtryzer™-NF. Methods: In the following, we dialyzed 5 hemodialysis patients who had a contraindication to full anticoagulation postoperatively or after renal biopsy with the Filtryzer™-NF. Results...
Journal Articles
Journal Articles
Journal Articles
Subject Area:
Nephrology
Blood Purif (2020) 49 (3): 281–288.
Published Online: 21 February 2020
... and 97 CVVH circuits in 39 patients. There was no overall difference in circuit lifespan. When no anticoagulation was used, median circuit survival time was shorter for CVVH circuits (5 h, 95% CI 3–7 vs. 10 h, 95% CI 8–13, p < 0.01). Moreover, CVVHD, lower platelets levels, and longer activated...
Journal Articles
Blood Purif (2018) 46 (4): 326–331.
Published Online: 31 August 2018
.... Second, CRRT can provide extra energy supply in septic AKI to improve the kidney energy balance in septic AKI. Third, the anticoagulant used in CRRT also regulates the inflammation in septic AKI. CRRT is not only a treatment to deal with the water balance and metabolic products, but also a method...
Journal Articles
Subject Area:
Nephrology
Blood Purif (2017) 43 (4): 279–289.
Published Online: 25 January 2017
...Akash Deep; Mohammad Zoha; Pompa Dutta Kukreja Effective delivery of continuous renal replacement therapy (CRRT) depends on the longevity of the filter and circuit used in the CRRT machine. Safe and effective anticoagulation is crucial for maintaining the patency of these circuits. In children...
Journal Articles
Subject Area:
Nephrology
Blood Purif (2015) 40 (3): 194–202.
Published Online: 22 August 2015
... to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements. Citrate Anticoagulation Continuous renal replacement therapy Hemofiltration Filter lifespan Clogging Citrate formulation Continuous renal replacement therapy...
Journal Articles
Journal Articles
Journal Articles
Journal Articles
Subject Area:
Nephrology
Blood Purif (2013) 36 (2): 136–145.
Published Online: 07 November 2013
...Karin Strobl; Jens Hartmann; Manfred Wallner; Martin Brandl; Dieter Falkenhagen Background/Aims: Because of a high monitoring demand and an ensuing need for automation of regional citrate anticoagulation (RCA), a new semi-automated target-oriented algorithm was developed. The aim of this study...
Journal Articles
Subject Area:
Nephrology
Blood Purif (2013) 34 (3-4): 336–343.
Published Online: 09 January 2013
...Julien Aniort; Thierry Petitclerc; Caroline Créput Background: Anticoagulation of the blood circuit with heparin is essential for hemodialysis, but exposes patients to several risks (bleeding, thrombocytopenia, etc.). The use of citric acid-based dialysate (CitA-D) allows the reduction of heparin...
Journal Articles
Subject Area:
Nephrology
Blood Purif (2012) 34 (2): 80–87.
Published Online: 24 October 2012
... a novel approach. Methods: The literature was reviewed for limitations of hybrid protocols, use of regional citrate anticoagulation (RCA) on hybrid systems and sensors for IHD and hybrid therapy. The novel hybrid program in the authors’ institution is presented as a plausible future direction...
Journal Articles
Subject Area:
Nephrology
Blood Purif (2012) 33 (4): 300–306.
Published Online: 31 May 2012
...Yixiong Zhang; Jianping Ning; Pouranan Veeraragoo; Yanchao Li; Siyuan Dai Background/Aims: Anticoagulation in hemodialysis (HD) patients at high risk of bleeding remains an intractable problem. Simulating endothelial cells by releasing anticoagulant on the membrane may be a promising alternative...
Journal Articles
Journal Articles
Subject Area:
Nephrology
Blood Purif (2012) 33 (1-3): 7–20.
Published Online: 11 November 2011
...M. Brandl; K. Strobl; J. Hartmann; K. Kellner; T. Posnicek; D. Falkenhagen Background: Citrate anticoagulation offers several advantages in comparison to conventional anticoagulation. Most algorithms for regional citrate-calcium anticoagulation are based on citrate and calcium chloride infusion...
Journal Articles
Subject Area:
Nephrology
Blood Purif (2011) 31 (1-3): 92–95.
Published Online: 10 January 2011
... or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements. An extracorporeal ambulatory device needs, as is the case with any intervention, to be efficacious, safe and acceptable to the patient. Dialysis Anticoagulation Blood access...
Journal Articles
Subject Area:
Nephrology
Blood Purif (2010) 30 (2): 79–83.
Published Online: 22 July 2010
... during Continuous Renal Replacement Therapy In Byung Kim Nigel Fealy Ian Baldwin Rinaldo Bellomo Department of Intensive Care Medicine, Austin Hospital, Melbourne, Vic., Australia Key Words Continuous renal replacement therapy Continuous hemofiltration Extracorporeal circuit Anticoagulation Acute...
Journal Articles
Subject Area:
Nephrology
Blood Purif (2010) 29 (2): 191–196.
Published Online: 08 January 2010
...Heleen M. Oudemans-van Straaten Background: Heparins are used for circuit anticoagulation during continuous renal replacement therapy (CRRT). Because heparins cause systemic anticoagulation, they increase the risk of bleeding. Citrate provides regional anticoagulation. Since citrate is a buffer...