Background: A new medium cut-off (MCO) membranes has been designed to achieve better removal capacities for middle and large middle molecules in hemodialysis (HD) treatment. Aim: The aim of this study was to evaluate the removal efficacy of Theranova® in standard HD in comparison with standard high-flux HD. Methods: Four HD patients (M/F 1/4) were included in 12-week observational pilot study in HD with Theranova® 400 and Theranova® 500 dialyzers. Each patient was assessed 4 times, T0 with high-flux dialyzers, T1 at 1 month, T2 at second month, and T3 at third month, by measuring pre- and post-HD samples of urea, Cr, β2-microglobilin (β2M), myoglobin, albumin, free light chains kappa (FLC-k), and free light chains lambda (FLC-λ). Results: The data showed a higher average removal rate for all the uremic toxins with Theranova® dialyzers for β2M, myoglobin, FLC-k, and FLC-λ (62.7, 56.9, 63.5, and 54.6%, respectively) during the 3 months. Albumin retention was observed and did not change between T0 and T3 (p = 0.379). Conclusion: Compared to high-flux membranes, MCO membranes show greater permeability for middle molecules in midterm report.

1.
Kramer
A
,
Pippias
M
,
Noordzij
M
,
Stel
V
,
Andrusev
A
,
Aparicio-Madre
M
, et al.
The european renal association – european dialysis and transplant association (ERA-EDTA) registry. Annual report 2016: a summary
.
Clin Kidney J
.
2019
:
1
19
.
2.
Ahmadmehrabi
S
,
Tang
WHW
.
Hemodialysis-induced cardiovascular disease
.
Semin Dial
.
2018
;
31
(
3
):
258
67
. .
3.
Collins
AJ
,
Foley
RN
,
Chavers
B
,
Gilbertson
D
,
Herzog
C
,
Johansen
K
, et al.
United States renal data system 2011 annual data report: atlas of chronic kidney disease & end-stage renal disease in the United States
.
Am J Kidney Dis
.
2012
;
59
(
1
):
e1
420
.
4.
Roberts
MA
,
Polkinghorne
KR
,
McDonald
SP
,
Ierino
FL
,
Ierino
FL
.
Secular trends in cardiovascular mortality rates of patients receiving dialysis compared with the general population
.
Am J Kidney Dis
.
2011
;
58
(
1
):
64
72
. .
5.
Vanholder
R
,
Schepers
E
,
Pletinck
A
,
Nagler
EV
,
Glorieux
G
.
The uremic toxicity of indoxyl sulfate and p-cresyl sulfate: a systematic review
.
J Am Soc Nephrol
.
2014
;
25
(
9
):
1897
. .
6.
Tattersall
J
,
Farrington
K
,
Gentile
G
,
Kooman
J
,
Macias Núñez
J
,
Nistor
I
, et al.
European renal best practice guidelines group and the european union of geriatric medicine societies (EUGMS) collaborative group for the production of guidelines on the management of older patients with CKD, Is Kt/V useful in elderly dialysis patients? pro and con arguments
.
Nephrol Dial Transplant
.
2018
;
33
(
5
):
742
50
.
7.
Cheung
AK
,
Rocco
MV
,
Yan
G
,
Leypoldt
JK
,
Levin
NW
,
Greene
T
, et al.
Serum beta-2 microglobulin levels predict mortality in dialysis patients: results of the HEMO study
.
J Am Soc Nephrol
.
2006
;
17
(
2
):
546
55
. .
8.
Meijers
B
,
Vanholder
R
.
HEMO revisited: why Kt/vurea only tells part of the story
.
J Am Soc Nephrol
.
2016
;
27
(
11
):
3235
7
. .
9.
Locatelli
F
,
Martin-Malo
A
,
Hannedouche
T
,
Loureiro
A
,
Papadimitriou
M
,
Wizemann
V
, et al.
Effect of membrane permeability on survival of hemodialysis patients
.
J Am Soc Nephrol
.
2009
;
20
(
3
):
645
54
. .
10.
Eloot
S
,
Van Biesen
W
,
Vanholder
R
.
A sad but forgotten truth: the story of slow-moving-solutes in fast hemodialysis
.
Semin Dial
.
2012
;
25
:
505
.
11.
Tattersall
JE
,
Ward
RA
.
EUDIAL group. Online haemodiafiltration: definition, dose quantification and safety revisited
.
Nephrol Dial Transplant
.
2013
;
28
:
542
50
.
12.
Schiffl
H
.
Online hemodiafiltration and mortality risk in end-stage renal disease patients: a critical appraisal of current evidence
.
Kidney Res Clin Pract
.
2019
;
38
(
2
):
159
68
. .
13.
Gejyo
F
,
Yamada
T
,
Odani
S
,
Nakagawa
Y
,
Arakawa
M
,
Kunitomo
T
, et al.
A new form of amyloid protein associated with chronic hemodialysis was identified as beta 2-microglobulin
.
Biochem Biophys Res Commun
.
1985
;
129
(
3
):
701
6
. .
14.
McCarthy
JT
,
Williams
AW
,
Johnson
WJ
.
Serum beta 2-microglobulin concentration in dialysis patients: importance of intrinsic renal function
.
J Lab Clin Med
.
1994
;
123
(
4
):
495
505
.
15.
Hartmann
J
,
Fricke
H
,
Schiffl
H
.
Biocompatible membranes preserve residual renal function in patients undergoing regular hemodialysis
.
Am J Kidney Dis
.
1997
;
30
(
3
):
366
73
. .
16.
Desjardins
L
,
Liabeuf
S
,
Lenglet
A
,
Lemke
HD
,
Vanholder
R
,
Choukroun
G
, et al.
Association between free light chain levels, and disease progression and mortality in chronic kidney disease
.
Toxins
.
2013
;
5
(
11
):
2058
73
. .
17.
RoumeliotiTrietley
MEG
,
Nolin
TD
,
Ng
JH
,
Xu
Z
,
Alaini
A
,
Figueroa
R
.
Beta-2 microglobulin clearance in high-flux dialysis and convective dialysis modalities: a meta-analysis of published studies
.
Nephrol Dial Transplant
.
2018
;
33
(
6
):
1025
39
.
18.
Ronco
C
,
Marchionna
N
,
Brendolan
A
,
Neri
M
,
Lorenzin
A
,
Martínez Rueda
AJ
.
Expanded haemodialysis: from operational mechanism to clinical results
.
Nephrol Dial Transplant
.
2018
;
33
(
3
):
41
7
.
19.
Kirsch
AH
,
Lyko
R
,
Nilsson
LG
,
Beck
W
,
Amdahl
M
,
Lechner
P
, et al.
Performance of hemodialysis with novel medium cut-off dialyzers
.
Nephrol Dial Transplant
.
2017
;
32
(
1
):
165
72
. .
20.
Fiedler
R
,
Neugebauer
F
,
Ulrich
C
,
Wienke
A
,
Gromann
C
,
Storr
M
, et al.
Randomized controlled pilot study of 2 weeksʼ treatment with high cutoff membrane for hemodialysis patients with elevated C-reactive protein
.
Artif Organs
.
2012
;
36
(
10
):
886
93
. .
21.
Gong
D
,
Ji
D
,
Zhang
K
,
Huang
X
,
Huang
G
,
Xu
B
, et al.
Endotoxemia after high cutoff hemodialysis for treatment of patient with multiple myeloma can be prevented by using ultrapure dialysate: a case report
.
Hemodial Int
.
2013
;
17
(
4
):
618
. .
22.
Lodebo
BT
,
Shah
A
,
Kopple
JD
.
Is it important to prevent and treat protein-energy wasting in chronic kidney disease and chronic dialysis patients?
J Ren Nutr
.
2018
;
28
(
6
):
369
79
. .
23.
Zweigart
C
,
Boschetti-de-Fierro
A
,
Hulko
M
,
Nilsson
LG
,
Beck
W
,
Storr
M
, et al.
Medium cut-off membranes: closer to the natural kidney removal function
.
Int J Artif Organs
.
2017
;
40
(
7
):
328
34
. .
24.
Daurgidas
JT
.
Second generation logarithmic estimates of single-pool variable volume Kt/V: an analysis of error
.
J Am Soc Nephrol
.
1993
;
4
(
5
):
1205
.
25.
Scarpioni
R
,
Ricardi
M
,
Albertazzi
V
,
De Amicis
S
,
Rastelli
F
,
Zerbini
L
.
Dialysis-related amyloidosis: challenges and solutions
.
Int J Nephrol Renovasc Dis
.
2016
;
9
:
319
28
. .
26.
Cho
NJ
,
Park
S
,
Islam
MI
,
Song
HY
,
Lee
EY
,
Gil
HW
.
Long-term effect of medium cut-off dialyzer on middle uremic toxins and cell-free hemoglobin
.
PLoS One
.
2019
;
14
(
7
):
e0220448
. .
27.
Clark
WR
,
Gao
D
,
Neri
M
,
Ronco
C
.
Solute transport in hemodialysis: advances and limitations of current membrane technology
.
Contrib Nephrol
.
2017
;
191
:
84
99
. .
28.
Ronco
C
.
The rise of expanded hemodialysis
.
Blood Purif
.
2017
;
44
:
1
8
.
29.
Cozzolino
M
,
Magagnoli
L
,
Ciceri
P
,
Conte
F
,
Galassi
A
.
Effects of a medium cut-off (Theranova®) dialyser on haemodialysis patients: a prospective, cross-over study
.
Clin Kidney J
.
sfz155
. .
30.
Ralli
C
,
Duranti
D
,
Imperiali
P
,
Bagnati
M
,
Filomena
P
,
Matteo
B
, et al.
Purifying capacity of a new membrane characterized by a medium cut-off and high performance
.
J Clin Exp Nephrol
.
2018
;(
3
):
5
.
31.
HulkoM
DV
,
Koch
I
,
Alexander
G
,
Michael
G
,
Werner
B
,
Krause
B
.
Pyrogen retention: comparison of the novel medium cut-off (MCO) membrane with other dialyser membranes
.
Sci Rep
.
2019
;
9
:
6791
. .
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.