Background: Central venous catheter (CVC) is commonly used to provide access for hemodialysis (HD) when arteriovenous access is not available. The misplacement of CVC into azygos vein (AV) is a rare but a potential serious complication. Previous reports communicated the opinion that left-sided catheterization predisposed to AV misplacement, but these reports concentrated on peripherally inserted CVCs, placed for indications rather than HD. Unintended AV misplacement of HD catheters (HDCs) has not been well studied. We seek to investigate factors associated with inadvertent AV miscannulation during HDC placement. Methods: We are to present a case of unintentional misplacement of a tunneled HD catheter (tHDC) into the azygos arch from right internal jugular vein (RIJV) despite real-time fluoroscopy guidance. Additionally, we have undertaken a systematic literature search in Pubmed to study the anatomical and other factors related to unintended AV misposition in HD setting. Results: From 2005 to August 31, 2018, a total of 11 articles containing 16 cases of misplacement of HDCs into AV were identified. Of the 17 cases of unintentional AV misposition including ours, the majority of the misguided HDCs (94.1%, 16/17) were tHDCs and only 1 case was related to a temporary (non-tunneled) catheter. Most catheter misplacements (88.2%, 15/17) were performed without real-time radiological guidance. The reported incidence of inadvertent AV cannulation from different institutions varied between 0.6% and 3.8%. Among the 16 misplaced tHDCs, the rates of AV misposition that arose from RIJV and left internal jugular vein (LIJV) insertion are even at 50%. Conclusions: Based upon anatomical and case studies, we have found that AV may join posterior aspect of superior vena cava at different directions and levels. Hence, this might explain why AV misplacement might occur whether an HDC is inserted from the LIJV or RIJV approach. By raising the awareness of this potential complication and how we may minimize it, we hope to reduce the future complication of AV misposition.

1.
Phibbs B. Central-venous-pressure monitoring. Localization of a catheter with teflon wire.
N Engl J Med
. 1966 Feb; 274(5): 270.
2.
Dudrick SJ, Wilmore DW, Vars HM, Rhoads JE. Long-term total parenteral nutrition with growth, development, and positive nitrogen balance.
Surgery
. 1968 Jul; 64(1): 134–42.
3.
McGee DC, Gould MK. Preventing complications of central venous catheterization.
N Engl J Med
. 2003 Mar; 348(12): 1123–33.
4.
Schwab SJ, Beathard G. The hemodialysis catheter conundrum: hate living with them, but can’t live without them.
Kidney Int
. 1999 Jul; 56(1): 1–17.
5.
Gibson F, Bodenham A. Misplaced central venous catheters: applied anatomy and practical management.
Br J Anaesth
. 2013 Mar; 110(3): 333–46.
6.
Sayani R, Anwar M, Tanveer-ul-Haq, Al-Qamari N, Bilal MA. Outcome of radiologically placed tunneled haemodialysis catheters.
J Coll Physicians Surg Pak
. 2013 Dec; 23(12): 837–41.
7.
Clark E, Kappel J, MacRae J, Dipchand C, Hiremath S, Kiaii M, et al.; Canadian Society of Nephrology Vascular Access Work Group. Practical Aspects of Nontunneled and Tunneled Hemodialysis Catheters.
Can J Kidney Health Dis
. 2016 Sep; 3: 2054358116669128.
8.
Wong JK, Sadler DJ, McCarthy M, Saliken JC, So CB, Gray RR. Analysis of early failure of tunneled hemodialysis catheters.
AJR Am J Roentgenol
. 2002 Aug; 179(2): 357–63.
9.
Langston CS. The aberrant central venous catheter and its complications.
Radiology
. 1971 Jul; 100(1): 55–9.
10.
Bankier AA, Mallek R, Wiesmayr MN, Fleischmann D, Kranz A, Kontrus M, et al. Azygos arch cannulation by central venous catheters: radiographic detection of malposition and subsequent complications.
J Thorac Imaging
. 1997 Jan; 12(1): 64–9.
11.
Weber E, Liberek T, Wołyniec W, Rutkowski B. Catheter tip malposition after percutaneous placement of tunneled hemodialysis catheters.
Hemodial Int
. 2015 Oct; 19(4): 509–13.
12.
Muhm M, Sunder-Plassmann G, Apsner R, Pernerstorfer T, Rajek A, Lassnigg A, et al. Malposition of central venous catheters. Incidence, management and preventive practices.
Wien Klin Wochenschr
. 1997 Jun; 109(11): 400–5.
13.
Franklin I, Gilmore C. Placement of a peripherally inserted central catheter into the azygous vein.
J Med Radiat Sci
. 2015 Jun; 62(2): 160–2.
14.
Pua U. Imaging teaching case. Radiographic features of malpositioning of a hemodialysis catheter in the azygos vein.
Am J Kidney Dis
. 2010 Feb; 55(2): 395–8.
15.
Marcy PY, Guiffant G, Merckx J, Lacout A. Diagnosis of azygos catheter misplacement.
J Vasc Access
. 2016 Sep; 17(5):e148–9.
16.
Harish K, Madhu YC. Inadvertent port: catheter placement in azygos vein.
Int J Angiol
. 2012 Jun; 21(2): 103–6.
17.
Mou LJ, Wang SH, Li QH, Zhang RS, Pan NZ, Wang JF. Malpositioning of a Tunneled Hemodialysis Catheter into the Azygos Vein: A Case Report and Literature Review.
Blood Purif
. 2017; 44(2): 108–9.
18.
Stewart GD, Jackson A, Beards SC. Azygos catheter placement as a cause of failure of dialysis.
Clin Radiol
. 1993 Nov; 48(5): 329–31.
19.
Granata A, Figuera M, Castellino S, Logias F, Basile A. Azygos arch cannulation by central venous catheters for hemodialysis.
J Vasc Access
. 2006 Jan-Mar; 7(1): 43–5.
20.
Calviño J, Bravo J, Martínez L, Millán B, Pulpeiro JR. Recognizing misplacement of a dialysis catheter in the azygos vein.
Hemodial Int
. 2013 Jul; 17(3): 455–7.
21.
Nayeemuddin M, Pherwani AD, Asquith JR. Imaging and management of complications of central venous catheters.
Clin Radiol
. 2013 May; 68(5): 529–44.
22.
Sampathkumar K, Prabhakar A, Saravanan R, Nayak MA. Misplaced tunneled catheter into azygos vein.
Indian J Nephrol
. 2015 Nov-Dec; 25(6): 384–5.
23.
Li Cavoli G, Schillaci O, Servillo F, Zagarrigo C, Li Cavoli TV, Palmeri M, et al. Malposition of the Central Venous Catheter in the Hemiazygos Vein.
Blood Purif
. 2016; 42(2): 168–9.
24.
Skandalos I, Hatzibaloglou A, Evagelou I, Ntitsias T, Samaras A, Visvardis G, et al. Deviations of placement/function of permanent central vein catheters for hemodialysis.
Int J Artif Organs
. 2005 Jun; 28(6): 583–90.
25.
Demant AW, Rattunde H, Abderhalden S, Von Vigier R, Wolf RW. Pitfall in pediatric dialysis: malposition of a dialysis catheter mimicking azygos continuation syndrome.
J Vasc Access
. 2007 Oct-Dec; 8(4): 302–4.
26.
Sherif MM, Hall R, Schauer CK. Azygos vein thrombosis secondary to a peripherally inserted central catheter (PICC).
J Vasc Access
. 2015 Jul; 16(4):e82–3.
27.
Currarino G. Migration of jugular or subclavian venous catheters into inferior tributaries of the brachiocephalic veins or into the azygos vein, with possible complications.
Pediatr Radiol
. 1996 Jul; 26(7): 439–49.
28.
Rosa UW, Foreman M, Willsie-Ediger S. Intermittent back pain after central venous catheter placement.
JPEN J Parenter Enteral Nutr
. 1993 Jan-Feb; 17(1): 91–3.
29.
Andrews MH, Chisholm BD. Spontaneous migration of a portacath into the azygos vein with subsequent development of a tracheo-azygos fistula.
J Med Imaging Radiat Oncol
. 2015 Apr; 59(2): 200–3.
30.
Chapter 55. In: Standring S.
Gray’s anatomy
. 2008. pp. 939–40.
31.
Prasanna LC, Thomas HR, Das A, Kumar R. Left-Sided Persistent Superior Vena Cava with Superior Hemiazygos Arch.
J Clin Diagn Res
. 2016 May; 10(5):AD03–05.
32.
Joskin J, Bleus N, Couvreur T, Tselikas L, Milicevic M. Duplicate inferior vena cava continuing as a hemiazygos continuation draining into the right atrium via persistent left superior vena cava.
JBR-BTR
. 2012 May-Jun; 95(3): 174.
33.
Kutoglu T, Turut M, Kocabiyik N, Ozan H, Yildirim M. Anatomical analysis of azygos vein system in human cadavers.
Rom J Morphol Embryol
. 2012; 53(4): 1051–6.
34.
Tatar I, Denk CC, Celik HH, Oto A, Karaosmanoglu DA, Ozdemir BM, et al. Anatomy of the azygos vein examined by computerized tomography imaging.
Saudi Med J
. 2008 Nov; 29(11): 1585–8.
35.
Heitzman ER. Radiologic appearance of the azygos vein in cardiovascular disease.
Circulation
. 1973 Mar; 47(3): 628–34.
36.
Hollinshead W.
Anatomy for surgeons
. 2nd ed. New York, USA: Harper & Row; 1971.
37.
Snell R. Clincial anatomy by regions. Biltimore MD: Lippincott Williams & Wilkins, Wolters Kluwer; 2012.
38.
Moore K, Dalley A, Agur A.
Clinically oriented Anatomy
. 7th ed. Baltimore, MD: Lippincott Williams & Wilkins, Wolters Kluwer; 2014
39.
Anson B, McVay C.
Surgical anatomy
. 60th ed. Igaku-Shoin Saunders (Tokyo): WB Saunders Co; 1984. pp. 464–5.
40.
Bales G. A semi-quantitative approach to variation of the azygos vein course.
Clin Anat
. 2014 Oct; 27(7): 1030–7.
41.
Levin N, Eknoyan G, Pipp M, Steinberg E. National Kidney Foundation: dialysis Outcome Quality Initiative–development of methodology for clinical practice guidelines.
Nephrol Dial Transplant
. 1997 Oct; 12(10): 2060–3.
42.
Gao Y, Liu Y, Zhang H, Fang F, Song L. The safety and accuracy of ECG-guided PICC tip position verification applied in patients with atrial fibrillation.
Ther Clin Risk Manag
. 2018 Jun; 14: 1075–81.
43.
Bream PR, Gu E. Use of an ECG-based confirmatory technique for bedside placement of reverse-tunneled cuffed dialysis catheters in three morbidly obese patients.
Kidney Int
. 2015 Sep; 88(3): 633–6.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.