Introduction: Glycated hemoglobin is used to assess diabetic control although its accuracy in dialysis has been questioned. How does it compare to the Continuous Glucose Monitoring System (CGMS) in peritoneal dialysis (PD) patients? Methods: We conducted a retrospective analysis of 60 insulin-treated diabetic patients on PD. We determined the mean interstitial glucose concentration and the proportion of patients with hypoglycemia (<4 mmol/l) or hyperglycemia (>11 mmol/l). Results: The correlation between HbA1c and glucose was 0.48, p < 0.0001. Three of 15 patients with HbA1c >75 mmol/mol experienced significant hypoglycemia (14-144 min per day). The patients with frequent episodes of hypoglycemia could not be differentiated from those with frequent hyperglycemia by demographics or PD prescription. Conclusion: HbA1c and average glucose levels measured by the CGMS are only weakly correlated. On its own, HbA1c as an indicator of glycemic control in patients with diabetes on PD appears inadequate. We suggest that the CGMS technology should be more widely adopted.

1.
Nathan DM, et al: Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes. N Engl J Med 2005;353:2643-2653.
2.
Yoo DE, et al: Good glycemic control is associated with better survival in diabetic patients on peritoneal dialysis: a prospective observational study. PLoS One 2012;7:e30072.
3.
Vos FE, Schollum JB, Walker RJ: Glycated albumin is the preferred marker for assessing glycaemic control in advanced chronic kidney disease. NDT Plus 2011;4:368-375.
4.
Speeckaert M, et al: Are there better alternatives than haemoglobin A1c to estimate glycaemic control in the chronic kidney disease population? Nephrol Dial Transplant 2014;29:2167-2177.
5.
Peacock TP, et al: Comparison of glycated albumin and hemoglobin A(1c) levels in diabetic subjects on hemodialysis. Kidney Int 2008;73:1062-1068.
6.
Chachou A, et al: Influence of in vivo hemoglobin carbamylation on HbA1c measurements by various methods. Clin Chem Lab Med 2000;38:321-326.
7.
Li PK, et al: Randomized, controlled trial of glucose-sparing peritoneal dialysis in diabetic patients. J Am Soc Nephrol 2013;24:1889-1900.
8.
Mastrototaro J, et al: The accuracy and efficacy of real-time continuous glucose monitoring sensor in patients with type 1 diabetes. Diabetes Technol Ther 2008;10:385-390.
9.
Szypowska A, et al: Beneficial effect of real-time continuous glucose monitoring system on glycemic control in type 1 diabetic patients: systematic review and meta-analysis of randomized trials. Eur J Endocrinol 2012;166:567-574.
10.
Girardin CM, et al: Continuous glucose monitoring: a review of biochemical perspectives and clinical use in type 1 diabetes. Clin Biochem 2009;42:136-142.
11.
Lee SY, et al: Glycosylated hemoglobin and albumin-corrected fructosamine are good indicators for glycemic control in peritoneal dialysis patients. PLoS One 2013;8:e57762.
12.
Marshall J, et al: Glycemic control in diabetic CAPD patients assessed by continuous glucose monitoring system (CGMS). Kidney Int 2003;64:1480-1486.
13.
Gerstein HC, et al: Long-term effects of intensive glucose lowering on cardiovascular outcomes. N Engl J Med 2011;364:818-828.
14.
Finfer S, et al: Intensive versus conventional glucose control in critically ill patients. N Engl J Med 2009;360:1283-1297.
15.
Macrae D, et al: A randomized trial of hyperglycemic control in pediatric intensive care. N Engl J Med 2014;370:107-118.
16.
Mellbin LG, et al: Does hypoglycaemia increase the risk of cardiovascular events? A report from the ORIGIN trial. Eur Heart J 2013;34:3137-3144.
17.
Banarer S, Cryer PE: Sleep-related hypoglycemia-associated autonomic failure in type 1 diabetes: reduced awakening from sleep during hypoglycemia. Diabetes 2003;52:1195-1203.
18.
Secrest AM, et al: Characterizing sudden death and dead-in-bed syndrome in type 1 diabetes: analysis from two childhood-onset type 1 diabetes registries. Diabet Med 2011;28:293-300.
19.
Tanenberg RJ, Newton CA, Drake AJ: Confirmation of hypoglycemia in the ‘dead-in-bed' syndrome, as captured by a retrospective continuous glucose monitoring system. Endocr Pract 2010;16:244-248.
20.
Herzog CA: Cardiac arrest in dialysis patients: approaches to alter an abysmal outcome. Kidney Int Suppl 2003;84:S197-S200.
21.
Chow E, et al: Risk of cardiac arrhythmias during hypoglycemia in patients with type 2 diabetes and cardiovascular risk. Diabetes 2014;63:1738-1747.
22.
Choudhary P, et al: Relationship between interstitial and blood glucose during hypoglycemia in subjects with type 2 diabetes. Diabetes Technol Ther 2011;13:1121-1127.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.