The wearable artificial kidney (WAK) is a device that is supposed to operate like a real kidney, which permits prolonged, frequent, and continuous dialysis treatments for patients with end-stage renal disease (ESRD). Its functioning is mainly related to its pumping system, as well as to its dialysate-generating and alarm/shutoff ones. A pump is defined as a device that moves fluids by mechanical action. In such a context, blood pumps pull blood from the access side of the dialysis catheter and return the blood at the same rate of flow. The main aim of this paper is to review the current literature on blood pumps, describing the way they have been functioning thus far and how they are being engineered, giving details about the most important parameters that define their quality, thus allowing the production of a radar comparative graph, and listing ideal pumps' features.

1.
Ronco C, Fecondini L: The Vicenza wearable artificial kidney for peritoneal dialysis (ViWAK PD). Blood Purif 2007;25:383-388.
2.
Davenport A: Portable or wearable peritoneal devices - the next step forward for peritoneal dialysis? Adv Perit Dial 2012;28:97-101.
3.
Tumlin J, Wali R, Williams W, Murray P, Tolwani AJ, Vinnikova AK, et al: Efficacy and safety of renal tubule cell therapy for acute renal failure. J Am Soc Nephrol 2008;19:1034-1040.
4.
Viktorsdottir O, Palsson R, Andresdottir MB, et al: Prevalence of chronic kidney disease based on estimated glomerular filtration rate and proteinuria in icelandic adults. Nephrol Dial Transplant 2005;20:1799-1807.
5.
Herrero Calvo JA: Servicio de Nefrologia. Nefrologia 2011;31:9-16.
6.
AWAK Technologies Inc., 2013.
7.
Fissell WH, Roy S, Davenport A: Continuous wearable hemodialysis devices. Kidney Int 2013;84:256-264.
8.
Gura V, Davenport A, Beizai M, et al: Beta2-microglobulin and phosphate clearances using a wearable artificial kidney: a pilot study. Am J Kidney Dis 2009;54:104-111.
9.
Gura V, Ronco C, Davenport A: The wearable artificial kidney, why and how: from holy grail to reality. Semin Dial 2009;22:13-17.
10.
International Vocabulary of Metrology - Basic and General Concepts and Associated Terms (VIM 3rd edition). JCM 200:2012.
11.
Taylor JR: An Introduction to Error Analysis: The Study of Uncertainties in Physical Measurements. University Science Books 2011, pp 128-129. ISBN 0-935702-75-X.
12.
Morrison RC: Weight and gravity - the need for consistent definitions. The Physics Teacher 1999;37:51.
13.
Galili I: Weight versus gravitational force: historical and educational perspectives. Int J Sci Educ 1999;23:1073-1093.
14.
The National Standard of Canada, CAN/CSA-Z234.1-89 Canadian Metric Practice Guide, 1989.
15.
Kellum JA, Bellomo R, Ronco C: Continuous renal replacement therapy. 2009;24:129-140.
16.
Gura V, Ronco C: Critical Care Nephrology, Continuous Renal Replacement Therapies, 2009, chapter 260, section 18.
17.
Principles of Continuous Renal Replacement Therapy, 2005 Orlando Regional Healthcare, Education & Development.
18.
Choi SW, Kang SM, Kim HY, Nam KW: Development and in vitro evaluation of a flow-adjustable elastic drug infusion pump. Proc Inst Mech Eng H 2011;225:1070-1077.
19.
Veres JP: Blood Pump, Kidney Replacement Services, P.C., BiBTeX, EndNote, RefMan, US6439845 B1.
20.
NMB Technologies Corporation, A Minebea Group Company, 2010.
21.
Toma DN: Gen Electric, BiBTeX, EndNote, RefMan.
22.
Ronco C, Jeong Chul K: The μ3D Project (Miniaturization of three devices in dialysis), 2011.
23.
Kim JC, Garzotto F, Nalesso F, et al: A wearable artificial kidney: technical requirements and potential solutions. Expert Rev Med Devices 2011;8:567-579.
24.
Kim JC, Ronco C: Personal daily dialysis: the evolution of the artificial kidney. Blood Purif 2013;36:47-51.
25.
Bennett M, et al: Pump-induced haemolysis: a comparison of short-term ventricular assist devices. Perfusion 2004;19:107-111.
26.
Tiedge S, et al: Erste Einsätze einer neuen Diagonalpumpe in extrakorporalen Unterstützungssystemen bei Kindern und Säuglingen. Kardiotechnik 2011;3:72-76.
27.
Kang J, Scholz T, Weaver JD, Ku DN, Rosen DW: Pump design for a portable renal replacement system. J Med Devices 2011;5:331-340.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.