The elimination of substances between 10 and 50 kDa by conventional high-flux membranes is not satisfactory. We investigated in vivo the elimination of middle-sized uremic solutes by conventional polyflux (PF) and modified high-cut-off (HCO) membranes. All 12 patients underwent four treatments, two with the HCO dialyzer and two with the PF dialyzer, each in either a haemodialysis (HD) or haemodiafiltration (HDF) mode. The reduction ratio of urea, creatinine, β2-microglobulin (β2M), leptin, soluble TNF-RI, complement factor D, IL-6, sIL-6 receptor, advanced glycation end-products (AGEs) and albumin was determined. In addition, the amount removed was determined in the dialysate for β2M, complement factor D, AGEs and albumin. Treatment with HCO removed β2M, sTNF-RI, factor D, and high molecular AGE significantly better than conventional high-flux membranes. The albumin loss was higher when using HCO membranes. HCO membranes are a promising approach to improve removal of uremic toxins not affected by conventional high-flux membranes.

1.
Duranton F, Cohen G, De Smet R, Rodriguez M, Jankowski J, Vanholder R, Argiles A, European Uremic Toxin Work Group: Normal and pathologic concentrations of uremic toxins. J Am Soc Nephrol 2012;23:1258-1270.
2.
Vanholder R, De Smet R, Glorieux G, Argiles A, Baurmeister U, Brunet P, Clark W, Cohen G, De Deyn PP, Deppisch R, Descamps-Latscha B, Henle T, Jorres A, Lemke HD, Massy ZA, Passlick-Deetjen J, Rodriguez M, Stegmayr B, Stenvinkel P, Tetta C, Wanner C, Zidek W: Review on uremic toxins: classification, concentration, and interindividual variability. Kidney Int 2003;63:1934-1943.
3.
Cheung AK, Rocco MV, Yan G, Leypoldt JK, Levin NW, Greene T, Agodoa L, Bailey J, Beck GJ, Clark W, Levey AS, Ornt DB, Schulman G, Schwab S, Teehan B, Eknoyan G: Serum β2-microglobulin levels predict mortality in dialysis patients: results of the HEMO study. J Am Soc Nephrol 2006;17:546-555.
4.
Liabeuf S, Lenglet A, Desjardins L, Neirynck N, Glorieux G, Lemke HD, Vanholder R, Diouf M, Choukroun G, Massy ZA, European Uremic Toxin Work Group: Plasma β2-microglobulin is associated with cardiovascular disease in uremic patients. Kidney Int 2012;82:1297-1303.
5.
Eknoyan G, Beck GJ, Cheung AK, Daugirdas JT, Greene T, Kusek JW, Allon M, Bailey J, Delmez JA, Depner TA, Dwyer JT, Levey AS, Levin NW, Milford E, Ornt DB, Rocco MV, Schulman G, Schwab SJ, Teehan BP, Toto R: Effect of dialysis dose and membrane flux in maintenance hemodialysis. N Engl J Med 2002;347:2010-2019.
6.
Locatelli F, Martin-Malo A, Hannedouche T, Loureiro A, Papadimitriou M, Wizemann V, Jacobson SH, Czekalski S, Ronco C, Vanholder R: Effect of membrane permeability on survival of hemodialysis patients. J Am Soc Nephrol 2009;20:645-654.
7.
Meert N, Eloot S, Waterloos MA, Van Landschoot M, Dhondt A, Glorieux G, Ledebo I, Vanholder R: Effective removal of protein-bound uraemic solutes by different convective strategies: a prospective trial. Nephrol Dial Transplant 2009;24:562-570.
8.
Canaud B, Bragg-Gresham JL, Marshall MR, Desmeules S, Gillespie BW, Depner T, Klassen P, Port FK: Mortality risk for patients receiving hemodiafiltration versus hemodialysis: European results from the DOPPS. Kidney Int 2006;69:2087-2093.
9.
Jirka T, Cesare S, Di Benedetto A, Perera Chang M, Ponce P, Richards N, Tetta C, Vaslaky L: Mortality risk for patients receiving hemodiafiltration versus hemodialysis. Kidney Int 2006;70:1524; author reply 1524-1525.
10.
Panichi V, Rizza GM, Paoletti S, Bigazzi R, Aloisi M, Barsotti G, Rindi P, Donati G, Antonelli A, Panicucci E, Tripepi G, Tetta C, Palla R: Chronic inflammation and mortality in haemodialysis: effect of different renal replacement therapies. Results from the RISCAVID study. Nephrol Dial Transplant 2008;23:2337-2343.
11.
Ok E, Asci G, Toz H, Ok ES, Kircelli F, Yilmaz M, Hur E, Demirci MS, Demirci C, Duman S, Basci A, Adam SM, Isik IO, Zengin M, Suleymanlar G, Yilmaz ME, Ozkahya M, Turkish Online Haemodiafiltration Study: Mortality and cardiovascular events in online haemodiafiltration (OL-HDF) compared with high-flux dialysis: results from the Turkish OL-HDF study. Nephrol Dial Transplant 2013;28:192-202.
12.
Maduell F, Moreso F, Pons M, Ramos R, Mora-Macia J, Carreras J, Soler J, Torres F, Campistol JM, Martinez-Castelao A, Group ES: High-efficiency postdilution online hemodiafiltration reduces all-cause mortality in hemodialysis patients. J Am Soc Nephrol 2013;24:487-497.
13.
Grooteman MP, van den Dorpel MA, Bots ML, Penne EL, van der Weerd NC, Mazairac AH, den Hoedt CH, van der Tweel I, Levesque R, Nube MJ, ter Wee PM, Blankestijn PJ, CONTRAST Investigators: Effect of online hemodiafiltration on all-cause mortality and cardiovascular outcomes. J Am Soc Nephrol 2012;23:1087-1096.
14.
Schindler R: Elimination of cytokines from plasma by ultrafiltration using conventional polysulfone or DIAPES membranes, in Locatelli F, Ronco C, Tetta C (eds): Polyethersulfone: Membranes for Multiple Clinical Applications. Contrib Nephrol. Basel, Karger, 2003, vol 138, pp 37-42.
15.
Henle T, Deppisch R, Beck W, Hergesell O, Hansch GM, Ritz E: Advanced glycated end-products during haemodialysis treatment: discrepant results with different methodologies reflecting the heterogeneity of age compounds. Nephrol Dial Transplant 1999;14:1968-1975.
16.
Oppermann M, Haubitz M, Quentin E, Götze O: Complement activation in patients with renal failure as detected through the quantitation of fragments of the complement proteins C3, C5, and factor B. Klin Wochenschr 1988;66:857-864.
17.
Santoro A, Canova C, Mancini E, Deppisch R, Beck W: Protein loss in on-line hemofiltration. Blood Purif 2004;22:261-268.
18.
Libby P, Ridker PM, Hansson GK: Inflammation in atherosclerosis: from pathophysiology to practice. J Am Coll Cardiol 2009;54:2129-2138.
19.
Mallamaci F, Tripepi G, Cutrupi S, Malatino LS, Zoccali C: Prognostic value of combined use of biomarkers of inflammation, endothelial dysfunction, and myocardiopathy in patients with ESRD. Kidney Int 2005;67:2330-2337.
20.
Ridker PM, Koenig W, Kastelein JJ: C-reactive protein in the heart protection study. Lancet 2011;377:1918; author reply 1918-1919.
21.
Liao KP, Solomon DH: Traditional cardiovascular risk factors, inflammation and cardiovascular risk in rheumatoid arthritis. Rheumatology (Oxford) 2013;52:45-52.
22.
Ridker PM, Danielson E, Fonseca FA, Genest J, Gotto AM Jr, Kastelein JJ, Koenig W, Libby P, Lorenzatti AJ, Macfadyen JG, Nordestgaard BG, Shepherd J, Willerson JT, Glynn RJ: Reduction in C-reactive protein and LDL cholesterol and cardiovascular event rates after initiation of rosuvastatin: a prospective study of the JUPITER trial. Lancet 2009;373:1175-1182.
23.
Ridker PM, Thuren T, Zalewski A, Libby P: Interleukin-1β inhibition and the prevention of recurrent cardiovascular events: rationale and design of the canakinumab anti-inflammatory thrombosis outcomes study (CANTOS). Am Heart J 2011;162:597-605.
24.
Morgera S, Slowinski T, Melzer C, Sobottke V, Vargas-Hein O, Volk T, Zuckermann-Becker H, Wegner B, Muller JM, Baumann G, Kox WJ, Bellomo R, Neumayer HH: Renal replacement therapy with high-cut-off hemofilters: impact of convection and diffusion on cytokine clearances and protein status. Am J Kidney Dis 2004;43:444-453.
25.
Heering P, Morgera S, Schmitz FJ, Schmitz G, Willers R, Schultheiss HP, Strauer BE, Grabensee B: Cytokine removal and cardiovascular hemodynamics in septic patients with continuous venovenous hemofiltration. Intensive Care Med 1997;23:288-296.
26.
Sanchez Izquierdo JA, Perez Vela JL, Lozano Quintana MJ, Alted Lopez E, Ortuno de Solo B, Ambros Checa A: Cytokines clearance during venovenous hemofiltration in the trauma patient. Am J Kidney Dis 1997;30:483-488.
27.
De Vriese AS, Colardyn FA, Philippe JJ, Vanholder RC, De Sutter JH, Lameire NH: Cytokine removal during continuous hemofiltration in septic patients. J Am Soc Nephrol 1999;10:846-853.
28.
Oppert M, Schindler R, Husung C, Offermann K, Graf KJ, Boenisch O, Barckow D, Frei U, Eckardt KU: Low-dose hydrocortisone improves shock reversal and reduces cytokine levels in early hyperdynamic septic shock. Crit Care Med 2005;33:2457-2464.
29.
Samtleben W, Dengler C, Reinhardt B, Nothdurft A, Lemke HD: Comparison of the new polyethersulfone high-flux membrane diapes HF800 with conventional high-flux membranes during on-line haemodiafiltration. Nephrol Dial Transplant 2003;18:2382-2386.
30.
Ward RA: Protein-leaking membranes for hemodialysis: a new class of membranes in search of an application? J Am Soc Nephrol 2005;16:2421-2430.
31.
Caravaca F, Arrobas M, Dominguez C: Serum albumin and other serum protein fractions in stable patients on peritoneal dialysis. Perit Dial Int 2000;20:703-707.
32.
Kaysen GA, Stevenson FT, Depner TA: Determinants of albumin concentration in hemodialysis patients. Am J Kidney Dis 1997;29:658-668.
33.
Galli F, Benedetti S, Floridi A, Canestrari F, Piroddi M, Buoncristiani E, Buoncristiani U: Glycoxidation and inflammatory markers in patients on treatment with PMMA-based protein-leaking dialyzers. Kidney Int 2005;67:750-759.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.