Background: Measurement of ionic dialysance has been shown to accurately determine urea dialyzer clearance and vascular access flow rate (Qa) in diffusive hemodialysis. Recently, online clearance monitoring (OCM) in an online hemodiafiltration (OL-HDF) machine could accurately measure urea dialyzer clearance. In the present study, OCM was utilized to assess the Qa in OL-HDF. Methods: In 32 stable end-stage renal disease patients undergoing predilution OL-HDF, the values of Qa measured by the OCM technique (QaOCMT) in a Fresenius 4008H HDF machine were compared with those determined by the standard ultrasound dilution technique (QaUDT). Results: The values of QaUDT and QaOCMT measured at the beginning of the HDF session were 800.5 ± 910.3 and 794.6 ± 895.4 ml/min (nonsignificant). There was a significant correlation between the two techniques (r = 0.95, p < 0.01). A Bland-Altman plot demonstrated a good agreement. Conclusion: The vascular access flow determined by OCM, which is integrated mostly in the current HDF machine, is highly accurate, easy to perform, and economical and can be used for vascular access surveillance in OL-HDF.

1.
Besarab A: Access monitoring is worthwhile and valuable. Blood purification 2006;24:77–89.
2.
Tordoir J, Canaud B, Haage P, Konner K, Basci A, Fouque D, Kooman J, Martin-Malo A, Pedrini L, Pizzarelli F, Tattersall J, Vennegoor M, Wanner C, ter Wee P, Vanholder R: EBPG on vascular access. Nephrol Dial Transplant 2007;22(suppl 2):ii88–ii117.
3.
NKF-K/DOQI: Clinical practice guidelines for vascular access: update 2006. Am J Kidney Dis 2006;48(suppl 1):S176–S247.
4.
Krivitski NM: Novel method to measure access flow during hemodialysis by ultrasound velocity dilution technique. ASAIO J 1995;41:M741–M745.
5.
Krivitski NM: Theory and validation of access flow measurement by dilution technique during hemodialysis. Kidney Int 1995;48:244–250.
6.
Krivitski NM, MacGibbon D, Gleed RD, Dobson A: Accuracy of dilution techniques for access flow measurement during hemodialysis. Am J Kidney Dis 1998;31:502–508.
7.
Mercadal L, Ridel C, Petitclerc T: Ionic dialysance: principle and review of its clinical relevance for quantification of hemodialysis efficiency. Hemodialysis Int 2005;9:111–119.
8.
Kuhlmann U, Goldau R, Samadi N, Graf T, Gross M, Orlandini G, Lange H: Accuracy and safety of online clearance monitoring based on conductivity variation. Nephrol Dial Transplant 2001;16:1053–1058.
9.
Lindsay RM, Bene B, Goux N, Heidenheim AP, Landgren C, Sternby J: Relationship between effective ionic dialysance and in vivo urea clearance during hemodialysis. Am J Kidney Dis 2001;38:565–574.
10.
Gotch FA, Buyaki R, Panlilio F, Folden T: Measurement of blood access flow rate during hemodialysis from conductivity dialysance. ASAIO J 1999;45:139–146.
11.
Mercadal L, Hamani A, Bene B, Petitclerc T: Determination of access blood flow from ionic dialysance: theory and validation. Kidney Int 1999;56:1560–1565.
12.
Lacson E Jr, Lazarus JM, Panlilio R, Gotch F: Comparison of hemodialysis blood access flow rates using online measurement of conductivity dialysance and ultrasound dilution. Am J Kidney Dis 2008;51:99–106.
13.
Whittier WL, Mansy HA, Rutz DR, Lewis AM, Sandler RH: Comparison of hemodialysis access flow measurements using flow dilution and in-line dialysance. ASAIO J 2009;55:369–372.
14.
Eloot S, Dhondt A, Hoeben H, Vanholder R: Comparison of different methods to assess fistula flow. Blood Purif 2010;30:89–95.
15.
Gross M, Maierhofer A, Tetta C, Senecal L, Canaud B: Online clearance measurement in high-efficiency hemodiafiltration. Kidney Int 2007;72:1550–1553.
16.
Blankestijn PJ, Ledebo I, Canaud B: Hemodiafiltration: clinical evidence and remaining questions. Kidney Int 2010;77:581–587.
17.
Lindsay RM, Blake PG, Malek P, Posen G, Martin B, Bradfield E: Hemodialysis access blood flow rates can be measured by a differential conductivity technique and are predictive of access clotting. Am J Kidney Dis 1997;30:475–482.
18.
Krivitski N: Hemodialysis access flow measurements using flow dilution and in-line dialysance are not interchangeable for hemodialysis access flow surveillance. ASAIO J 2010;56:79, author reply 80.
19.
Yarar D, Cheung AK, Sakiewicz P, Lindsay RM, Paganini EP, Steuer RR, Leypoldt JK: Ultrafiltration method for measuring vascular access flow rates during hemodialysis. Kidney Int 1999;56:1129–1135.
20.
Ragg JL, Treacy JP, Snelling P, Flack M, Anderton S: Confidence limits of arteriovenous fistula flow rate measured by the ‘on-line’ thermodilution technique. Nephrol Dial Transplant 2003;18:955–960.
21.
Wijnen E, van der Sande FM, Kooman JP, de Graaf T, Tordoir JH, Leunissen KM, Schneditz D: Measurement of hemodialysis vascular access flow using extracorporeal temperature gradients. Kidney Int 2007;72:736–741.
22.
Steuer RR, Miller DR, Zhang S, Bell DA, Leypoldt JK: Noninvasive transcutaneous determination of access blood flow rate. Kidney Int 2001;60:284–291.
23.
Magnasco A, Alloatti S, Martinoli C, Solari P: Glucose pump test: a new method for blood flow measurements. Nephrol Dial Transplant 2002;17:2244–2248.
24.
Tiranathanagul K, Katavetin P, Injan P, Leelahavanichkul A, Techawathanawanna N, Praditpornsilpa K, Srisawat N, Tungsanga K, Eiam-Ong S: A novel simple hemoglobin dilution technique to measure hemodialysis vascular access flow. Kidney Int 2008;73:1082–1086.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.