Migration of a cochlear implant electrode is a hitherto uncommon complication. So far, array migration has only been observed in lateral wall electrodes. Between 1999 and 2014, a total of 27 patients received bilateral perimodiolar electrode arrays at our institution. The insertion depth angle was estimated on the initial postoperative scans and compared with the insertion depth angle of the postoperative scans performed after contralateral cochlear implantation. Seven (25.93%) patients were found to have an electrode array migration of more than 15°. Electrode migration in perimodiolar electrodes seems to be less frequent and to occur to a lower extent than in lateral wall electrodes. Electrode migration was clinically asymptomatic in all cases.

1.
Adunka OF, Buchman CA: Cochlear implant fixation in children using periosteal sutures. Otol Neurotol 2007;28:768-770.
2.
Adunka O, Gstoettner W, Hambek M, Unkelbach MH, Radeloff A, Kiefer J: Preservation of basal inner ear structures in cochlear implantation. ORL J Otorhinolaryngol Relat Spec 2004;66:306-312.
3.
Balkany TJ, Whitley M, Shapira Y, Angeli SI, Brown K, Eter E, Van De Water T, Telischi FF, Eshraghi AA, Treaba C: The temporalis pocket technique for cochlear implantation: an anatomic and clinical study. Otol Neurotol 2009;30:903-907.
4.
Basta D, Todt I, Ernst A: Audiological outcome of the pull-back technique in cochlear implantees. Laryngoscope 2010;120:1391-1396.
5.
Boscolo-Rizzo P, Muzzi E, Barillari MR, Trabalzini F: Non-sutured fixation of the internal receiver-stimulator in cochlear implantation. Eur Arch Otorhinolaryngol 2011;268:961-965.
6.
Connell SS, Balkany TJ, Hodges AV, Telischi FF, Angeli SI, Eshraghi AA: Electrode migration after cochlear implantation. Otol Neurotol 2008;29:156-159.
7.
Cuda D: A simplified fixation of the new thin cochlear implant receiver-stimulators in children: long term results with the ‘back-pocket' technique. Int J Pediatr Otorhinolaryngol 2013;77:1158-1161.
8.
Davis BM, Labadie RF, McMenomey SO, Haynes DS: Cochlear implant fixation using polypropylene mesh and titanium screws. Laryngoscope 2004;114:2116-2118.
9.
Gekeler J, Luers JC, Lang-Roth R, Beutner D: Cochlear implant fixation: are sutures really necessary? Eur Arch Otorhinolaryngol 2013;270:483-487.
10.
Green KM, Bhatt YM, Saeed SR, Ramsden RT: Complications following adult cochlear implantation: experience in Manchester. J Laryngol Otol 2004;118:417-420.
11.
Gstöttner W, Pok SM, Peters S, Kiefer J, Adunka O: Cochlear implantation with preservation of residual deep frequency hearing (in German). HNO 2005;53:784-790.
12.
Hochmair I, Arnold W, Nopp P, Jolly C, Muller J, Roland P: Deep electrode insertion in cochlear implants: apical morphology, electrodes and speech perception results. Acta Otolaryngol 2003;123:612-617.
13.
Hoffman RA, Cohen NL: Complications of cochlear implant surgery. Ann Otol Rhinol Laryngol Suppl 1995;166:420-422.
14.
Jethanamest D, Channer GA, Moss WJ, Lustig LR, Telischi FF: Cochlear implant fixation using a subperiosteal tight pocket without either suture or bone-recess technique. Laryngoscope 2014;124:1674-1677.
15.
Lee DJ, Driver M: Cochlear implant fixation using titanium screws. Laryngoscope 2005;115:910-911.
16.
Molony TB, Giles JE, Thompson TL, Motamedi KK: Device fixation in cochlear implantation: is bone anchoring necessary? Laryngoscope 2010;120:1837-1839.
17.
Muller J, Schon F, Helms J: Reliable fixation of cochlear implant electrode mountings in children and adults - initial experiences with a new titanium clip (in German). Laryngorhinootologie 1998;77:238-240.
18.
Rivas A, Marlowe AL, Chinnici JE, Niparko JK, Francis HW: Revision cochlear implantation surgery in adults: indications and results. Otol Neurotol 2008;29:639-648.
19.
Roland JT Jr, Fishman AJ, Waltzman SB, Alexiades G, Hoffman RA, Cohen NL: Stability of the cochlear implant array in children. Laryngoscope 1998;108:1119-1123.
20.
Schnabl J, Wolf-Magele A, Pok SM, Url C, Zorowka P, Sprinzl G: Evaluation of a minimally invasive surgical fixation technique for young children with the Concerto Pin cochlear implant system. Eur Arch Otorhinolaryngol 2014, Epub ahead of print.
21.
Sunde J, Webb JB, Moore PC, Gluth MB, Dornhoffer JL: Cochlear implant failure, revision, and reimplantation. Otol Neurotol 2013;34:1670-1674.
22.
Todt I, Basta D, Ernst A: Does the surgical approach in cochlear implantation influence the occurrence of postoperative vertigo? Otolaryngol Head Neck Surg 2008;138:8-12.
23.
van der Marel KS, Verbist BM, Briaire JJ, Joemai RM, Frijns JH: Electrode migration in cochlear implant patients: not an exception. Audiol Neurootol 2012;17:275-281.
24.
Verbist BM, Skinner MW, Cohen LT, Leake PA, James C, Boex C, Holden TA, Finley CC, Roland PS, Roland JT Jr, Haller M, Patrick JF, Jolly CN, Faltys MA, Briaire JJ, Frijns JH: Consensus panel on a cochlear coordinate system applicable in histologic, physiologic, and radiologic studies of the human cochlea. Otol Neurotol 2010;31:722-730.
25.
Wang JT, Wang AY, Psarros C, Da Cruz M: Rates of revision and device failure in cochlear implant surgery: a 30-year experience. Laryngoscope 2014;124:2393-2399.
26.
Xu J, Xu SA, Cohen LT, Clark GM: Cochlear view: postoperative radiography for cochlear implantation. Am J Otol 2000;21:49-56.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.