Electric-acoustic stimulation (EAS) was developed for individuals with a profound hearing loss in the high frequencies and a substantial residual low-frequency hearing (LFH). For this group of candidates, conventional hearing aids often neither provided sufficient amplification nor were they considered suitable for cochlear implantation due to the possible destruction of residual hearing capabilities. With EAS, combining electric stimulation with an ipsilateral acoustic stimulation, preservation of residual LFH and the development of a new speech processor uniting both strategies became essential. Over the last years, EAS has developed further and advanced in electrode design and surgery techniques. This paper summarizes the history of EAS and acknowledges the tremendous work of the many research groups who contributed to the success of EAS.

1.
Adunka O, Buchman CA: Scala tympani cochleostomy. I. Results of a survey. Laryngoscope 2007;117:2187–2194.
2.
Adunka O, Buss E, Clark MS, Pillsbury HC, Buchman CA: Effect of preoperative residual hearing on speech perception after cochlear implantation. Laryngoscope 2008;118:2044–2049.
3.
Adunka O, Gstoettner W, Hambek M, Unkelbach MH, Radeloff A, Kiefer J: Preservation of basal inner ear structures in cochlear implantation. ORL J Otorhinolaryngol Relat Spec 2004a;66:306–312.
4.
Adunka O, Kiefer J: Impact of electrode insertion depth on intracochlear trauma. Otolaryngol Head Neck Surg 2006;135:374–382.
5.
Adunka O, Kiefer J, Unkelbach MH, Lehnert T, Gstoettner W: Development and evaluation of an improved cochlear implant electrode design for electric acoustic stimulation. Laryngoscope 2004b;114:1237–1241.
6.
Adunka O, Kiefer J, Unkelbach MH, Radeloff A, Gstoettner W: Evaluating cochlear implant trauma to the scala vestibuli. Clin Otolaryngol 2005a;30:121–127.
7.
Adunka O, Radeloff A, Gstoettner WK, Pillsbury HC, Buchman CA: Scala tympani cochleostomy. II. Topography and histology. Laryngoscope 2007;117:2195–2200.
8.
Adunka O, Roush P, Grose J, Macpherson C, Buchman CA: Monitoring of cochlear function during cochlear implantation. Laryngoscope 2006;116:1017–1020.
9.
Adunka O, Unkelbach MH, Mack M, Hambek M, Gstoettner W, Kiefer J: Cochlear implantation via the round window membrane minimizes trauma to cochlear structures: a histologically controlled insertion study. Acta Otolaryngol 2004c;124:807–812.
10.
Adunka O, Unkelbach MH, Mack MG, Radeloff A, Gstoettner W: Predicting basal cochlear length for electric-acoustic stimulation. Arch Otolaryngol Head Neck Surg 2005b; 131:488–492.
11.
Amos NE, Humes LE: Contribution of high frequencies to speech recognition in quiet and noise in listeners with varying degrees of high-frequency sensorineural hearing loss. J Speech Lang Hear Res 2007;50:819–834.
12.
Armstrong M, Pegg P, James C, Blamey P: Speech perception in noise with implant and hearing aid. Am J Otol 1997;18:S140–S141.
13.
Baer T, Moore BC, Kluk K: Effects of low pass filtering on the intelligibility of speech in noise for people with and without dead regions at high frequencies. J Acoust Soc Am 2002;112:1133–1144.
14.
Balkany TJ, Connell SS, Hodges AV, Payne SL, Telischi FF, Eshraghi AA, Angeli SI, Germani R, Messiah S, Arheart KL: Conservation of residual acoustic hearing after cochlear implantation. Otol Neurotol 2006;27:1083–1088.
15.
Baumann U, Helbig S: Hearing with combined electric acoustic stimulation (in German). HNO 2009;57:542–550.
16.
Baumann U, Nobbe A: Pitch ranking with deeply inserted electrode arrays. Ear Hear 2004;25:275–283.
17.
Baumann U, Nobbe A: The cochlear implant electrode-pitch function. Hear Res 2006;213:34–42.
18.
Baumgartner WD, Jappel A, Morera C, Gstoettner W, Müller J, Kiefer J, van de Heyning P, Anderson I, Bryde Nielsen S: Outcomes in adults implanted with the FLEXsoft electrode. Acta Otolaryngol 2007;127:579–586.
19.
Berrettini S, Forli F, Passetti S: Preservation of residual hearing following cochlear implantation: comparison between three surgical techniques. J Laryngol Otol 2008;122:246–252.
20.
Berrettini S, Passetti S, Giannarelli M, Forli F: Benefit from bimodal hearing in a group of prelingually deafened adult cochlear implant users. Am J Otolaryngol 2010;31:332–338.
21.
Boggess WJM, Baker JEMC, Balkany TJM: Loss of residual hearing after cochlear implantation. Laryngoscope 1989;99:1002–1005.
22.
Briggs R, Tykocinski M, Stidham K, Roberson JB: Cochleostomy site: implications for electrode placement and hearing preservation. Acta Otolaryngol 2005;125:870–876.
23.
Briggs R, Tykocinski M, Xu J, Risi F, Svehla M, Cowan R, Stöver T, Erfurt P, Lenarz T: Comparison of round window and cochleostomy approaches with a prototype hearing preservation electrode. Audiol Neurootol 2006;11(suppl 1):42–48.
24.
Brockmeier SJ, Peterreins M, Lorens A, Vermeire K, Helbig S, Anderson I, Skarzynski H, van de Heyning P, Gstoettner W, Kiefer J: Music perception in electric acoustic stimulation users as assessed by the Mu.S.I.C. Test; in van de Heyning P, Kleine Punte A (eds): Cochlear Implants and Hearing Preservation. Adv Otolaryngol. Basel, Karger, 2010, vol 67, pp 70–80.
25.
Buechner A, Schüssler M, Battmer RD, Stöver T, Lesinski-Schiedat A, Lenarz T: Impact of low-frequency hearing. Audiol Neurootol 2009;14(suppl 1):8–13.
26.
Chang A, Eastwood H, Sly D, James D, Richardson R, O’Leary S: Factors influencing the efficacy of round window dexamethasone protection of residual hearing post-cochlear implant surgery. Hear Res 2009;255:67–72.
27.
Chang JE, Bai JY, Zeng FG: Unintelligible low-frequency sound enhances simulated cochlear-implant speech recognition in noise. IEEE Trans Biomed Eng 2006;53:2598–2601.
28.
Charlet de Sauvage R, Lima da Costa D, Erre JP, Aran JM: Electrical and physiological changes during short-term and chronic electrical stimulation of the normal cochlea. Hear Res 1997;110:119–134.
29.
Ching T, Incerti P, Hill M: Binaural benefits for adults who use hearing aids and cochlear implants in opposite ears. Ear Hear 2004;25:9–21.
30.
Ching T, Psarros C, Hill M, Dillon H, Incerti P: Should children who use cochlear implants wear hearing aids in the opposite ear? Ear Hear 2001;22:365–380.
31.
Ching T, van Wanrooy E, Dillon H: Binaural-bimodal fitting or bilateral implantation for managing severe to profound deafness: a review. Trends Amplif 2007;11:161–192.
32.
Conlin AE, Parnes LS: Treatment of sudden sensorineural hearing loss. I. A systematic review. Arch Otolaryngol Head Neck Surg 2007a;133:573–581.
33.
Conlin AE, Parnes LS: Treatment of sudden sensorineural hearing loss. II. A meta-analysis. Arch Otolaryngol Head Neck Surg 2007b; 133:582–586.
34.
Connor SE, Bell DJ, O’Gorman R, Fitzgerald-O’Connor A: CT and MR imaging cochlear distance measurements may predict cochlear implant length required for a 360 degrees insertion. AJNR Am J Neuroradiol 2009;30:1425–1430.
35.
Cullen RD, Higgins C, Buss E, Clark M, Pillsbury HC 3rd, Buchman CA: Cochlear implantation in patients with substantial residual hearing. Laryngoscope 2004;114:2218–2223.
36.
Deman PR, van Dijk B, Offeciers FE, Govaerts PJ: Pitch estimation of a deeply inserted cochlear implant electrode. Int J Audiol 2004;43:363–368.
37.
Dettman SJ, D’Costa WA, Dowell RC, Winton EJ, Hill KL, Williams SS: Cochlear implants for children with significant residual hearing. Arch Otolaryngol Head Neck Surg 2004;130:612–618.
38.
Dietrich V, Nieschalk M, Stoll W, Rajan R, Pantev C: Cortical reorganization in patients with high frequency cochlear hearing loss. Hear Res 2001;158:95–101.
39.
di Nardo W, Cantore I, Melillo P, Cianfrone F, Scorpecci A, Paludetti G: Residual hearing in cochlear implant patients. Eur Arch Otorhinolaryngol 2007;264:855–860.
40.
Dorman M, Gifford R, Lewis K, McKarns S, Ratigan J, Spahr A, Shallop JK, Driscoll CL, Luetje C, Thedinger BS, Beatty C, Syms M, Novak M, Barrs D, Cowdrey L, Black J, Loiselle L: Word recognition following implantation of conventional and 10-mm hybrid electrodes. Audiol Neurootol 2009;14:181–189.
41.
Dorman M, Gifford RH, Spahr AJ, McKarns SA: The benefits of combining acoustic and electric stimulation for the recognition of speech, voice and melodies. Audiol Neurootol 2008;13:105–112.
42.
Dorman M, Loizou PC, Spahr A, Dana CJ: Simulations of combined acoustic/electric hearing engineering in medicine and biology. 25th Annual International Conference of the IEEE, Cancun, , 2003, pp 1999–2001.
43.
Dorman M, Spahr T, Gifford R, Loiselle L, McKay S, Holden T, Skinner M, Finley C: An electric frequency-to-place map for a cochlear implant patient with hearing in the nonimplanted ear. J Assoc Res Otolaryngol 2007;8:234–240.
44.
Dorman M, Spahr AJ, Loizou PC, Dana CJ, Schmidt JS: Acoustic simulations of combined electric and acoustic hearing (EAS). Ear Hear 2005;26:371–380.
45.
Dowell RC, Hollow R, Winton E: Outcomes for cochlear implant users with significant residual hearing: implications for selection criteria in children. Arch Otolaryngol Head Neck Surg 2004;130:575–581.
46.
Dunn CC, Tyler RS, Witt SA: Benefit of wearing a hearing aid on the unimplanted ear in adult users of a cochlear implant. J Speech Lang Hear Res 2005;48:668–680.
47.
El Fata F, James CJ, Laborde ML, Fraysse B: How much residual hearing is ‘useful’ for music perception with cochlear implants? Audiol Neurootol 2009;14(suppl 1):14–21.
48.
Erixon E, Högstorp H, Wadin K, Rask-Andersen H: Variational anatomy of the human cochlea: implications for cochlear implantation. Otol Neurotol 2009;30:14–22.
49.
Escude B, James C, Deguine O, Cochard N, Eter E, Fraysse B: The size of the cochlea and predictions of insertion depth angles for cochlear implant electrodes. Audiol Neurootol 2006;11(suppl 1):27–33.
50.
Eshraghi AA, Adil E, He J, Graves R, Balkany TJ, van de Water TR: Local dexamethasone therapy conserves hearing in an animal model of electrode insertion trauma-induced hearing loss. Otol Neurotol 2007;28:842–849.
51.
Eshraghi AA, He J, Mou CH, Polak M, Zine A, Bonny C, Balkany TJ, van de Water TR: D-JNKI-1 treatment prevents the progression of hearing loss in a guinea pig model of cochlear implantation trauma. Otol Neurotol 2006;27:504–511.
52.
Farahmand Ghavi F, Mirzadeh H, Imani M, Jolly C, Farhadi M: Corticosteroid-releasing cochlear implant: a novel hybrid of biomaterial and drug delivery system. J Biomed Mater Res B Appl Biomater 2010;94:388–398.
53.
Fayad J, Linthicum FH Jr, Otto SR, Galey FR, House WF: Cochlear implants: histopathologic findings related to performance in 16 human temporal bones. Ann Otol Rhinol Laryngol 1991;100:807–811.
54.
Fitzgerald M, Sagi E, Jackson M, Shapiro W, Roland J Jr, Waltzman S, Svirsky M: Reimplantation of hybrid cochlear implant users with a full-length electrode after loss of residual hearing. Otol Neurotol 2008;29:168–173.
55.
Fitzpatrick E, Olds J, Durieux-Smith A, McCrae R, Schramm D, Gaboury I: Pediatric cochlear implantation: how much hearing is too much? Int J Audiol 2009;48:91–97.
56.
Fraysse B, Dillier N, Klenzner T, Laszig R, Manrique M, Morera Perez C, Morgan A, Mueller-Deile J, Macias AR: Cochlear implants for adults obtaining marginal benefit from acoustic amplification: a European study. Am J Otol 1998;19:591–597.
57.
Fraysse B, Macias AR, Sterkers O, Burdo S, Ramsden R, Deguine O, Klenzner T, Lenarz T, Rodriguez MM, von Wallenberg E, James C: Residual hearing conservation and electroacoustic stimulation with the Nucleus 24 Contour Advance cochlear implant. Otol Neurotol 2006;27:624–633.
58.
Gantz BJ, Hansen MR, Turner CW, Oleson JJ, Reiss LA, Parkinson AJ: Hybrid 10 Clinical Trial: preliminary results. Audiol Neurootol 2009;14(suppl 1):32–38.
59.
Gantz BJ, Rubinstein JT, Tyler RS, Teagle HF, Cohen NL, Waltzman SB, Miyamoto RT, Kirk KI: Long-term results of cochlear implants in children with residual hearing. Ann Otol Rhinol Laryngol Suppl 2000;185:33–36.
60.
Gantz BJ, Turner CW: Combining acoustic and electrical hearing. Laryngoscope 2003;113:1726–1730.
61.
Gantz BJ, Turner CW: Combining acoustic and electrical speech processing: Iowa/Nucleus hybrid implant. Acta Otolaryngol 2004;124:344–347.
62.
Gantz BJ, Turner CW, Gfeller KE, Lowder MW: Preservation of hearing in cochlear implant surgery: advantages of combined electrical and acoustical speech processing. Laryngoscope 2005;115:796–802.
63.
Garcia-Ibanez L, Macias AR, Morera C, Rodriguez MM, Szyfter W, Skarszynski H, Emamdjomeh H, Baumgartner W: An evaluation of the preservation of residual hearing with the Nucleus Contour Advance electrode. Acta Otolaryngol 2009;129:651–664.
64.
Gfeller K, Olszewski C, Turner C, Gantz B, Oleson J: Music perception with cochlear implants and residual hearing. Audiol Neurootol 2006;11(suppl 1):12–15.
65.
Gfeller K, Turner C, Oleson J, Zhang X, Gantz B, Froman R, Olszewski C: Accuracy of cochlear implant recipients on pitch perception, melody recognition, and speech reception in noise. Ear Hear 2007;28:412–423.
66.
Gifford RH, Dorman MF, Brown CA: Psychophysical properties of low-frequency hearing: implications for perceiving speech and music via electric and acoustic stimulation; in van de Heyning P, Kleine Punte A (eds): Cochlear Implants and Hearing Preservation. Adv Otolaryngol. Basel, Karger, 2010, vol 67, pp 51–60.
67.
Gifford R, Dorman M, McKarns S, Spahr A: Combined electric and contralateral acoustic hearing: word and sentence intelligibility with bimodal hearing. J Speech Lang Hear Res 2007a;50:835–843.
68.
Gifford RH, Dorman MF, Spahr AJ, Bacon SP, Skarzynski H, Lorens A: Hearing preservation surgery: psychophysical estimates of cochlear damage in recipients of a short electrode array. J Acoust Soc Am 2008;124:2164–2173.
69.
Gifford RH, Dorman MF, Spahr AJ, McKarns SA: Effect of digital frequency compression (DFC) on speech recognition in candidates for combined electric and acoustic stimulation (EAS). J Speech Lang Hear Res 2007b;50:1194–1202.
70.
Glista D, Scollie S, Bagatto M, Seewald R, Parsa V, Johnson A: Evaluation of nonlinear frequency compression: clinical outcomes. Int J Audiol 2009;48:632–644.
71.
Greenwood DD: Critical bandwidth and the frequency coordinates of the basilar membrane. J Acoust Soc Am 1961;33:1344–1356.
72.
Gstoettner W, Adunka O, Franz P, Hamzavi J, Plenk H, Susani M, Baumgartner W, Kiefer J: Perimodiolar electrodes in cochlear implant surgery. Acta Otolaryngol 2001;121:216–219.
73.
Gstoettner W, Franz P, Hamzavi J, Plenk H Jr, Baumgartner W, Czerny C: Intracochlear position of cochlear implant electrodes. Acta Otolaryngol 1999;119:229–233.
74.
Gstoettner W, Helbig S, Maier N, Kiefer J, Radeloff A, Adunka O: Ipsilateral electric acoustic stimulation of the auditory system: results of long-term hearing preservation. Audiol Neurootol 2006;11(suppl 1):49–56.
75.
Gstoettner W, Helbig S, Settevendemie C, Baumann U, Wagenblast J, Arnoldner C: A new electrode for residual hearing preservation in cochlear implantation: first clinical results. Acta Otolaryngol 2009;129:372–379.
76.
Gstoettner W, Kiefer J, Baumgartner WD, Pok S, Peters S, Adunka O: Hearing preservation in cochlear implantation for electric acoustic stimulation. Acta Otolaryngol 2004;124:348–352.
77.
Gstoettner W, Pok SM, Peters S, Kiefer J, Adunka O: Cochlear implantation with preservation of residual deep frequency hearing (in German). HNO 2005;53:784–790.
78.
Gstoettner W, van de Heyning P, O’Connor A, Morera C, Sainz M, Vermeire K, McDonald S, Cavallé L, Helbig S, Valdecasas JG, Anderson I, Adunka O: Electric acoustic stimulation of the auditory system: results of a multi-centre investigation. Acta Otolaryngol 2008;128:968–975.
79.
Hagerman B: Sentences for testing speech intelligibility in noise. Scand Audiol 1982;11:79–87.
80.
Hamzavi J, Arnoldner C: Effect of deep insertion of the cochlear implant electrode array on pitch estimation and speech perception. Acta Otolaryngol 2006;126:1182–1187.
81.
Hamzavi J, Pok SM, Gstoettner W, Baumgartner WD: Speech perception with a cochlear implant used in conjunction with a hearing aid in the opposite ear. Int J Audiol 2004;43:61–65.
82.
Hartmann R, Topp G, Klinke R: Discharge patterns of cat primary auditory fibers with electrical stimulation of the cochlea. Hear Res 1984;13:47–62.
83.
Hartrampf R, Dahm MC, Battmer RD, Gnadeberg D, Strauss-Schier A, Rost U, Lenarz T: Insertion depth of the Nucleus electrode array and relative performance. Ann Otol Rhinol Laryngol 1995;166:277–280.
84.
Hedrick MS, Jesteadt W: Effect of relative amplitude, presentation level, and vowel duration on perception of voiceless stop consonants by normal and hearing-impaired listeners. J Acoust Soc Am 1996;100:3398–3407.
85.
Hedrick MS, Schulte L, Jesteadt W: Effect of relative and overall amplitude on perception of voiceless stop consonants by listeners with normal and impaired hearing. J Acoust Soc Am 1995;98:1292–1303.
86.
Helbig S, Baumann U: Acceptance and fitting of the DUET device: a combined speech processor for electric-acoustic stimulation; in van de Heyning P, Kleine Punte A (eds): Cochlear Implants and Hearing Preservation. Adv Otolaryngol. Basel, Karger, 2010, vol 67, pp 81–87.
87.
Helbig S, Baumann U, Helbig M, von Malsen-Waldkirch N, Gstoettner W: A new combined speech processor for electric and acoustic stimulation: eight months experience. ORL J Otorhinolaryngol Relat Spec 2008;70:359–365.
88.
Helbig S, Helbig M, Rader T, Mack M, Baumann U: Cochlear reimplantation after surgery for electric-acoustic stimulation. ORL J Otorhinolaryngol Relat Spec 2009;71:172–178.
89.
Hillmann TH, Arriaga MA, Chen D: Intratympanic steroids: do they acutely improve hearing in cases of cochlear hydrops? Laryngoscope 2003;113:1903–1907.
90.
Hochmair I, Arnold W, Nopp P, Jolly C, Müller J, Roland P: Deep electrode insertion in cochlear implants: apical morphology, electrodes and speech perception results. Acta Otolaryngol 2003;123:612–617.
91.
Hogan CA, Turner CW: High-frequency audibility: benefits for hearing-impaired listeners. J Acoust Soc Am 1998;104:432–441.
92.
Hornsby BW, Ricketts TA: The effects of hearing loss on the contribution of high- and low-frequency speech information to speech understanding. II. Sloping hearing loss. J Acoust Soc Am 2006;119:1752–1763.
93.
Huettenbrink KB, Zahnert T, Hofmann G, Kronholz G, Jolly C: Visualization of cochlear implant electrode movements in the cochlea by using X-ray microscopy (in German). Laryngorhinootologie 2001;80:66–70.
94.
James C, Albegger K, Battmer R, Burdo S, Deggouj N, Deguine O, Dillier N, Gersdorff M, Laszig R, Lenarz T, Rodriguez MM, Mondain M, Offeciers E, Macias AR, Ramsden R, Sterkers O, von Wallenberg E, Weber B, Fraysse B: Preservation of residual hearing with cochlear implantation: how and why. Acta Otolaryngol 2005;125:481–491.
95.
James DP, Eastwood H, Richardson RT, O’Leary SJ: Effects of round window dexamethasone on residual hearing in a Guinea pig model of cochlear implantation. Audiol Neurootol 2008;13:86–96.
96.
Javel E, Shepherd RK: Electrical stimulation of the auditory nerve. III. Response initiation sites and temporal fine structure. Hear Res 2000;140:45–76.
97.
Ketten DR, Skinner MW, Wang G, Vannier MW, Gates GA, Neely JG: In vivo measures of cochlear length and insertion depth of nucleus cochlear implant electrode arrays. Ann Otol Rhinol Laryngol Suppl 1998;175:1–16.
98.
Kiang NY, Moxon EC: Physiological considerations in artificial stimulation of the inner ear. Ann Otol Rhinol Laryngol 1972;81:714–730.
99.
Kiefer J, Böhnke F, Adunka O, Arnold W: Representation of acoustic signals in the human cochlea in presence of a cochlear implant electrode. Hear Res 2006;221:36–43.
100.
Kiefer J, Gstoettner W, Baumgartner W, Pok S, Tillein J, Ye Q, von Ilberg C: Conservation of low-frequency hearing in cochlear implantation. Acta Otolaryngol 2004a;124:272–280.
101.
Kiefer J, Pok M, Adunka O, Stuerzebecher E, Baumgartner W, Schmidt M, Tillein J, Ye Q, Gstoettner W: Combined electric and acoustic stimulation of the auditory system: results of a clinical study. Audiol Neurootol 2005;10:134–144.
102.
Kiefer J, Tillein J, von Ilberg C, Pfennigdorff T, Stuerzebecher E, Klinke R, Gstoettner W: Fundamental aspects and first results of the clinical application of combined electrical and acoustical stimulation of the auditory system; in Kubo T, Takahashi Y, Iwaki T (eds): Cochlear Implants. An Update. The Hague, Kugler, 2002, pp 569–576.
103.
Kiefer J, Tillein J, Ye Q, Klinke R, Gstoettner W: Application of carbon dioxide and erbium: yttrium-aluminum-garnet lasers in inner ear surgery: an experimental study. Otol Neurotol 2004b;25:400–409.
104.
Kiefer J, von Ilberg C, Reimer B, Knecht R, Gall V, Diller G, Stuerzebecher E, Pfennigdorff T, Spelsberg A: Results of cochlear implantation in patients with severe to profound hearing loss: implications for patient selection. Audiology 1998;37:382–395.
105.
Kiefer J, Ye Q, Tillein J, Adunka O, Arnold W, Gstoettner W: Protecting the cochlea during stapes surgery: is there a role for corticosteroids? Adv Otorhinolaryngol 2007;65:300–307.
106.
Kleine Punte A, Vermeire K, van de Heyning P: Bilateral electric acoustic stimulation: a comparison of partial and deep cochlear electrode insertion; in van de Heyning P, Kleine Punte A (eds): Cochlear Implants and Hearing Preservation. Adv Otolaryngol. Basel, Karger, 2010, vol 67, pp 144–152.
107.
Klenzner T, Stecker M, Marangos N, Laszig R: Extended indications for cochlear implantation: the Freiburg results in patients with residual hearing (in German). HNO 1999;47:95–100.
108.
Kong Y, Stickney G, Zeng F-G: Speech and melody recognition in binaurally combined acoustic and electric hearing. J Acoust Soc Am 2005;117:1351–1361.
109.
Kuk F, Keenan D, Korhonen P, Lau CC: Efficacy of linear frequency transposition on consonant identification in quiet and in noise. J Am Acad Audiol 2009;20:465–479.
110.
Kurzweg T: Evaluation of Cochlear Implant Electrode Position: A Comparative Histological and Radiological Temporal Bone Study (in German); dissertation, University of Magdeburg, 2008.
111.
Kurzweg T, Dalchow CV, Bremke M, Majdani O, Kureck I, Knecht R, Werner JA, Teymoortash A: The value of digital volume tomography in assessing the position of cochlear implant arrays in temporal bone specimens. Ear Hear 2010;31:413–419.
112.
Lamm K, Arnold W: The effect of prednisolone and non-steroidal anti-inflammatory agents on the normal and noise-damaged guinea pig inner ear. Hear Res 1998;115:149–161.
113.
Lamm K, Lamm H, Arnold W: Effect of hyperbaric oxygen therapy in comparison to conventional or placebo therapy or no treatment in idiopathic sudden hearing loss, acoustic trauma, noise-induced hearing loss and tinnitus: a literature survey. Adv Otorhinolaryngol 1998;54:86–99.
114.
Leake PA, Hradek GT, Snyder RL: Chronic electrical stimulation by a cochlear implant promotes survival of spiral ganglion neurons after neonatal deafness. J Comp Neurol 1999;412:543–562.
115.
Leake PA, Hradek GT, Vollmer M, Rebscher SJ: Neurotrophic effects of GM1 ganglioside and electrical stimulation on cochlear spiral ganglion neurons in cats deafened as neonates. J Comp Neurol 2007;501:837–853.
116.
Leake PA, Snyder RL, Hradek GT, Rebscher SJ: Consequences of chronic extracochlear electrical stimulation in neonatally deafened cats. Hear Res 1995;82:65–80.
117.
Lehnhardt E: Intracochlear placement of cochlear implant electrodes in soft surgery technique (in German). HNO 1993;41:356–359.
118.
Lenarz T: Cochlear implants: selection criteria and shifting borders. Acta Otorhinolaryngol Belg 1998;52:183–199.
119.
Lenarz T, Stöver T, Buechner A, Lesinski-Schiedat A, Patrick J, Pesch J: Hearing conservation surgery using the Hybrid-L electrode: results from the first clinical trial at the Medical University of Hannover. Audiol Neurootol 2009;14(suppl 1):22–31.
120.
Lenarz T, Stöver T, Buechner A, Paasche G, Briggs R, Risi F, Pesch J, Battmer RD: Temporal bone results and hearing preservation with a new straight electrode. Audiol Neurootol 2006;11(suppl 1):34–41.
121.
Li PM, Somdas MA, Eddington DK, Nadol JB Jr: Analysis of intracochlear new bone and fibrous tissue formation in human subjects with cochlear implants. Ann Otol Rhinol Laryngol 2007;116:731–738.
122.
Linthicum FH Jr, Fayad J, Otto SR, Galey FR, House WF: Cochlear implant histopathology. Am J Otol 1991a;12:245–311.
123.
Linthicum FH Jr, Fayad J, Otto S, Galey FR, House WF: Inner ear morphologic changes resulting from cochlear implantation. Am J Otol 1991b;12(suppl):8–10, discussion 18–21.
124.
Lorens A, Polak M, Piotrowska A, Skarzynski H: Outcomes of treatment of partial deafness with cochlear implantation: a DUET study. Laryngoscope 2008;118:288–294.
125.
Luetje CM, Thedinger BS, Buckler LR, Dawson KL, Lisbona KL: Hybrid cochlear implantation: clinical results and critical review in 13 cases. Otol Neurotol 2007;28:473–478.
126.
Maini S, Lisnichuk H, Eastwood H, Pinder D, James D, Richardson RT, Chang A, Connolly T, Sly D, Kel G, O’Leary SJ: Targeted therapy of the inner ear. Audiol Neurootol 2009;14:402–410.
127.
Manrique MJ, Savall J, Cervera-Paz FJ, Rey J, Der C, Echeverria M, Ares M: Atraumatic surgical approach to the cochlea with a micromanipulator. Acta Otolaryngol 2007;127:122–131.
128.
Marsh MA, Xu J, Blamey PJ, Whitford LA, Xu SA, Silverman JM, Clark GM: Radiologic evaluation of multichannel intracochlear implant insertion depth. Am J Otol 1993;14:386–391.
129.
McDermott HJ, Knight MR: Preliminary results with the AVR ImpaCt frequency-transposing hearing aid. J Am Acad Audiol 2001;12:121–127.
130.
McDermott HJ, Sucher CM: Perceptual dissimilarities among acoustic stimuli and ipsilateral electric stimuli. Hear Res 2006;218:81–88.
131.
Miller CA, Abbas PJ, Robinson BK, Nourski KV, Zhang F, Jeng FC: Auditory nerve fiber responses to combined acoustic and electric stimulation. J Assoc Res Otolaryngol 2009;10:425–445.
132.
Mok M, Grayden D, Dowell RC, Lawrence D: Speech perception for adults who use hearing aids in conjunction with cochlear implants in opposite ears. J Speech Lang Hear Res 2006;49:338–351.
133.
Munro KJ, Walker AJ, Purdy SC: Evidence for adaptive plasticity in elderly monaural hearing aid users. Neuroreport 2007;18:1237–1240.
134.
Nadol JB Jr, Shiao JY, Burgess BJ, Ketten DR, Eddington DK, Gantz BJ, Kos I, Montandon P, Coker NJ, Roland JT Jr, Shallop JK: Histopathology of cochlear implants in humans. Ann Otol Rhinol Laryngol 2001;110:883–891.
135.
Neumann M, Aschendorff A, Schipper J, Laszig R, Klenzner T: The influence of insertion depth on the preservation of residual hearing after cochlear implantation (in German). Laryngorhinootologie 2005;84:113–116.
136.
Niedermeyer HP, Zahneisen G, Luppa P, Busch R, Arnold W: Cortisol levels in the human perilymph after intravenous administration of prednisolone. Audiol Neurootol 2003;8:316–321.
137.
Novak MA, Black JM, Koch DB: Standard cochlear implantation of adults with residual low-frequency hearing: implications for combined electro-acoustic stimulation. Otol Neurotol 2007;28:609–614.
138.
Oghalai JS, Tonini R, Rasmus J, Emery C, Manolidis S, Vrabec JT, Haymond J: Intra-operative monitoring of cochlear function during cochlear implantation. Cochlear Implants Int 2009;10:1–18.
139.
O’Leary MJ, Fayad J, House WF, Linthicum FH Jr: Electrode insertion trauma in cochlear implantation. Ann Otol Rhinol Laryngol 1991;100:695–699.
140.
Otte J, Schuknecht HF, Kerr AG: Ganglion cell populations in normal and pathological human cochleae: implications for cochlear im- plantation. Laryngoscope 1978;88:1231–1246.
141.
Paprocki A, Biskup B, Kozlowska K, Kuniszyk A, Bien D, Niemczyk K: The topographical anatomy of the round window and related structures for the purpose of cochlear implant surgery. Folia Morphol (Warsz) 2004;63:309–312.
142.
Pau HW, Just T, Bornitz M, Lasurashvilli N, Zahnert T: Noise exposure of the inner ear during drilling a cochleostomy for cochlear implantation. Laryngoscope 2007;117:535–540.
143.
Philibert B, Collet L, Vesson JF, Veuillet E: The auditory acclimatization effect in sensorineural hearing-impaired listeners: evidence for functional plasticity. Hear Res 2005;205:131–142.
144.
Plontke SK, Biegner T, Kammerer B, Delabar U, Salt AN: Dexamethasone concentration gradients along scala tympani after application to the round window membrane. Otol Neurotol 2008;29:401–406.
145.
Proctor B, Bollobas B, Niparko JK: Anatomy of the round window niche. Ann Otol Rhinol Laryngol 1986;95:444–446.
146.
Radeloff A, Unkelbach MH, Tillein J, Braun S, Helbig S, Gstoettner W, Adunka OF: Impact of intrascalar blood on hearing. Laryngoscope 2007;117:58–62.
147.
Reiss LA, Turner CW, Erenberg SR, Gantz B: Changes in pitch with a cochlear implant over time. J Assoc Res Otol 2007;8:241–257.
148.
Richter B, Aschendorff A, Lohnstein P, Husstedt H, Nagursky H, Laszig R: The Nucleus Contour electrode array: a radiological and histological study. Laryngoscope 2001;111:508–514.
149.
Rizer FM, Arkis PN, Lippy WH, Schuring AG: A postoperative audiometric evaluation of cochlear implant patients. Otolaryngol Head Neck Surg 1988;98:203–206.
150.
Robinson JD, Baer T, Moore BC: Using transposition to improve consonant discrimination and detection for listeners with severe high-frequency hearing loss. Int J Audiol 2007;46:293–308.
151.
Roland JT Jr: A model for cochlear implant electrode insertion and force evaluation: results with a new electrode design and insertion technique. Laryngoscope 2005;115:1325–1339.
152.
Roland JT Jr, Zeitler DM, Jethanamest D, Huang TC: Evaluation of the short hybrid electrode in human temporal bones. Otol Neurotol 2008;29:482–488.
153.
Roland PS, Wright CG: Surgical aspects of cochlear implantation: mechanisms of insertional trauma. Adv Otorhinolaryngol 2006;64:11–30.
154.
Roland PS, Wright CG, Isaacson B: Cochlear implant electrode insertion: the round window revisited. Laryngoscope 2007;117:1397–1402.
155.
Sakata E, Kitago Y, Murata Y, Teramoto K: Treatment of Ménière’s disease: middle ear infusion with lidocaine and steroid solution (in German). Auris Nasus Larynx 1986;13:79–89.
156.
Scarpidis U, Madnani D, Shoemaker C, Fletcher C, Kojima K, Eshraghi A, Staecker H, Lefebvre P, Malgrange B, Balkany T, van de Water T: Arrest of apoptosis in auditory neurons: implications for sensorineural preservation in cochlear implantation. Otol Neurotol 2003;24:409–417.
157.
Shepherd RF, Pyman BC, Clark GM, Webb RL: Banded intracochlear electrode array: evaluation of insertion trauma in human temporal bones. Ann Otol Rhinol Laryngol 1985;94:55–59.
158.
Simpson A, Hersbach AA, McDermott HJ: Improvements in speech perception with an experimental nonlinear frequency compression hearing device. Int J Audiol 2005;44:281–292.
159.
Simpson A, Hersbach AA, McDermott HJ: Frequency-compression outcomes in listeners with steeply sloping audiograms. Int J Audiol 2006;45:619–629.
160.
Simpson A, McDermott HJ, Dowell RC, Sucher C, Briggs RJS: Comparison of two frequency-to-electrode maps for acoustic-electric stimulation. Int J Audiol 2009;48:63–73.
161.
Skarzynski H, Lorens A: Electric acoustic stimulation in children; in van de Heyning P, Kleine Punte A (eds): Cochlear Implants and Hearing Preservation. Adv Otolaryngol. Basel, Karger, 2010, vol 67, pp 135–143.
162.
Skarzynski H, Lorens A, D’Haese P, Walkowiak A, Piotrowska A, Sliwa L, Anderson I: Preservation of residual hearing in children and post-lingually deafened adults after cochlear implantation: an initial study. ORL J Otorhinolaryngol Relat Spec 2002;64:247–253.
163.
Skarzynski H, Lorens A, Piotrowska A: A new method of partial deafness treatment. Med Sci Monit 2003;9:CS20–CS24.
164.
Skarzynski H, Lorens A, Piotrowska A, Anderson I: Partial deafness cochlear implantation provides benefit to a new population of individuals with hearing loss. Acta Otolaryngol 2006;126:934–940.
165.
Skarzynski H, Lorens A, Piotrowska A, Anderson I: Partial deafness cochlear implantation in children. Int J Pediatr Otorhinolaryngol 2007a;71:1407–1413.
166.
Skarzynski H, Lorens A, Piotrowska A, Anderson I: Preservation of low frequency hearing in partial deafness cochlear implantation (PDCI) using the round window surgical approach. Acta Otolaryngol 2007b;127:41–48.
167.
Skarzynski H, Lorens A, Piotrowska A, Podskarbi-Fayette R: Results of partial deafness cochlear implantation using various electrode designs. Audiol Neurootol 2009;14(suppl 1): 39–45.
168.
Skarzynski H, Podskarbi-Fayette R: A new cochlear implant electrode design for preservation of residual hearing: a temporal bone study. Acta Otolaryngol 2010;130:435–442.
169.
Skinner MW, Ketten DR, Holden LK, Harding GW, Smith PG, Gates GA, Neely JG, Kletzker GR, Brunsden B, Blocker B: CT-derived estimation of cochlear morphology and electrode array position in relation to word recognition in Nucleus-22 recipients. J Assoc Res Otolaryngol 2002;3:332–350.
170.
Smouha EE: Surgery of the inner ear with hearing preservation: serial histological changes. Laryngoscope 2003;113:1439–1449.
171.
Staecker H, Brough DE, Praetorius M, Baker K: Drug delivery to the inner ear using gene therapy. Otolaryngol Clin North Am 2004;37:1091–1108.
172.
Staecker H, Praetorius M, Baker K, Brough DE: Vestibular hair cell regeneration and restoration of balance function induced by math1 gene transfer. Otol Neurotol 2007;28:223–231.
173.
Stöver T, Issing P, Graurock G, Erfurt P, El Betagy Y, Paasche G, Lenarz T: Evaluation of the advance off-stylet insertion technique and the cochlear insertion tool in temporal bones. Otol Neurootol 2005;26:1161–1170.
174.
Stone MA, Moore BC: Tolerable hearing aid delays. II. Estimation of limits imposed during speech production. Ear Hear 2002;23:325–338.
175.
Stone MA, Moore BC: Tolerable hearing aid delays. III. Effects on speech production and perception of across-frequency variation in delay. Ear Hear 2003;24:175–183.
176.
Su WY, Marion MS, Hinojosa R, Matz GJ: Anatomical measurements of the cochlear aqueduct, round window membrane, round window niche, and facial recess. Laryngoscope 1982;92:483–486.
177.
Talbot KN, Hartley DE: Combined electro-acoustic stimulation: a beneficial union? Clin Otolaryngol 2008;33:536–545.
178.
Tillein J, Kral A, Hartmann R, Klinke R: Effects of simultaneous electric and acoustic stimulation (EAS) on temporal response patterns of cat single auditory nerve fibers (abstract 656). Assoc Res Otolaryngol 2003.
179.
Tillein J, Kral A, Pfennigdorff T, Hartmann R, Kiefer J, von Ilberg C, Klinke R: Intracochlear chronical electrical stimulation of the normal hearing guinea pig (abstract 5381). Assoc Res Otolaryngol 2000.
180.
Tillein J, Vollmer M, Kral A, Klinke R, Hartmann R: Interactions between electrical and acoustical auditory nerve fiber responses of intracochlear implanted cats with residual hearing (abstract 565). Assoc Res Otolaryngol 2004.
181.
Tobita T, Senarita M, Hara A, Kusakari J: Determination of prednisolone in the cochlear tissue. Hear Res 2002;165:30–34.
182.
Turner C, Gantz BJ, Reiss L: Integration of acoustic and electrical hearing. J Rehabil Res Dev 2008a;45:769–778.
183.
Turner C, Gantz BJ, Vidal C, Behrens A, Henry BA: Speech recognition in noise for cochlear implant listeners: benefits of residual acoustic hearing. J Acoust Soc Am 2004;115:1729–1735.
184.
Turner C, Hurtig RR: Proportional frequency compression of speech for listeners with sensorineural hearing loss. J Acoust Soc Am 1999;106:877–886.
185.
Turner C, Reiss LA, Gantz BJ: Combined acoustic and electric hearing: preserving residual acoustic hearing. Hear Res 2008b;242:164–171.
186.
Tykocinski M, Cohen LT, Pyman BC, Roland T Jr, Treaba C, Palamara J, Dahm MC, Shepherd RK, Xu J, Cowan RS, Cohen NL, Clark GM: Comparison of electrode position in the human cochlea using various perimodiolar electrode arrays. Am J Otol 2000;21:205–211.
187.
Usami S, Miyagawa M, Suzuki N, Moteki H, Nishoi S, Tajznumi Y, Iwasaki S: Genetic background of candidates for EAS (Electric-Acoustic Stimulation). Audiol Med 2010;8:28–32.
188.
van den Honert C, Stypulkowski PH: Physiological properties of the electrically stimulated auditory nerve. II. Single fiber recordings. Hear Res 1984;14:225–243.
189.
Vermeire K, Anderson I, Flynn M, van de Heyning P: The influence of different speech processor and hearing aid settings on speech perception outcomes in electric acoustic stimulation patients. Ear Hear 2008;29:76–86.
190.
Vickers DA, Moore BC, Baer T: Effects of low-pass filtering on the intelligibility of speech in quiet for people with and without dead regions at high frequencies. J Acoust Soc Am 2001;110:1164–1175.
191.
Vivero RJ, Joseph DE, Angeli S, He J, Chen S, Eshraghi AA, Balkany TJ, van de Water TR: Dexamethasone base conserves hearing from electrode trauma-induced hearing loss. Laryngoscope 2008;118:2028–2035.
192.
Vollmer M, Hartmann R, Tillein J: Neuronal responses in cat inferior colliculus to combined acoustic and electric stimulation. Adv Otorhinolaryngol 2010;67:61–69.
193.
von Ilberg C, Kiefer J, Tillein J, Pfennigdorff T, Hartmann R, Stuerzebecher E, Klinke R: Electric-acoustic stimulation of the auditory system: new technology for severe hearing loss. ORL J Otorhinolaryngol Relat Spec 1999;61:334–340.
194.
Welling DB, Hinojosa R, Gantz BJ, Lee J: Insertional trauma of multichannel cochlear implants. Laryngoscope 1993;103:995–1001.
195.
Wilson BS, Lawson DT, Muller JM, Tyler RS, Kiefer J: Cochlear implants: some likely next steps. Annu Rev Biomed Eng 2003;5:207–249.
196.
Wysocki J, Skarzynski H: Distances between the cochlea and adjacent structures related to cochlear implant surgery. Surg Radiol Anat 1998;20:267–271.
197.
Yao WN, Turner CW, Gantz BJ: Stability of low-frequency residual hearing in patients who are candidates for combined acoustic plus electric hearing. J Speech Lang Hear Res 2006;49:1085–1090.
198.
Ye Q, Kiefer J, Tillein J, Klinke R, Gstoettner W: Intracochlear application of steroids: an experimental study in guinea pigs. Cochlear Implants Int 2004;5(suppl 1):17–18.
199.
Ye Q, Tillein J, Hartmann R, Gstoettner W, Kiefer J: Application of a corticosteroid (Triamcinolon) protects inner ear function after surgical intervention. Ear Hear 2007;28:361–369.
200.
Zou J, Bretlau P, Pyykkö I, Toppila E, Olovius NP, Stephanson N, Beck O, Miller JM: Comparison of the protective efficacy of neurotrophins and antioxidants for vibration-induced trauma. ORL J Otorhinolaryngol Relat Spec 2003;65:155–161.
201.
Zrunek M, Lischka M: Dimensions of the scala vestibuli and sectional areas of both scales. Arch Otorhinolaryngol 1981;233:99–104.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.